Resource Management For Main Receiving Station Take Over Point 11 Kv , Map Pump House At Harni Camp And Provn Of Submersible Pump For Maintenance Of Stn Greens At Af Stn Baroda , Resource Management Of Mes Main Recieving Station Ht 11 Kv At Harni For Three Shifts , With One Mate Elect Cum Fgm Each Shift Round The Clock , 24 Hours ( I . E Three Shift Per Day ) Including Sundays & Gazette Holidays For Operation Complete All As Specified And Directed . , 1St Shift - 0600H To 1400H , 2Nd Shift - 1400H To 2200H , 3Rd Shift - 2200H To 0600H , The Sub Station Consisit The Following Equipment:- , Vaccum Circuit Breaker Type 11000 Volts . Make : Areva - 03 As Outgoing , Rmu - 01 For Incomming ( Make:Areva ) . , Vaccum Circuit Breaker Type 11000 Volts . Make : Areva - 03 As Outgoing , Rmu - 01 For Incomming ( Make:Areva ) . , Transformer 200 Kva - 01 No . , Lt Panel For Outgoing Feeder To Pump House , Domestic Area , Street Lights , Parameter Lights . , Centrifugal Pump Of Cap 40 Hp - 03 Nos , Lt Panel For Outgoing Feeder To 2231 Sqdn , Street Lights . , Resource Management For Water Supply Map Pump House Installation With One Fgm Operater In Each Shift Round The Clock , 24 Hours ( I . E Three Shift Per Day ) Including Sundays & Gazette Holidays For Operation Of Pump Set And Diesel Engine ( Stand By ) Including Operation Of Connected Valves , Maintain Equipment In Perfect Conditions , Maintaining Proper Timing Of Distribution Of Water Supply , Maintaining Proper Condition Of Equipments , Cleaning Of Installation And Surrounding Areas As Directed By Engineer-In-Charge At Pump And Consisting Of The Following:- , Ist Shift - 0600H To 1400H , Iind Shift - 1400H To 2200H , Iiird Shift - 2200H To 0600H , Centrifugal Pump Type Db 80 / 20 ( Make Kirloskar ) , 2900 Rpm , Motor- 25Hp Capacity - 02 Nos . , Electrical Panel Board Consisting Of Following 2 Nos , Oil Immersed Starter 25 Hp Make Jyoti- 02 Nos . , Standby Diesel Engine Generator Set ( Make Greaves ) Capacity 63 Kva Complete With Panel Board , Battery 180 Ah And Battery Charger - 01 No . , Chloronome Plant Pressure Feed , 200 Gms / Hr ( Make:- Sweta ) - 01 Nos . , Pump House Bldg Including Connected Accessories , Internal Wiring , Sluice Valves , Pipe Lines Etc . , Note For Ser Item No . 1 And 2 , The Contractor Shall Employ Fgm / Electrician Shall Be Iti Pass Or Minimum Matriculate With Three Years Experence In The Trade From Recognized Government Institute And Helper Minimum 8Th Pass From Reconized Government Institution , Staff Will Always Remain On Duty & Shift Staff Shall Not Change Over Duty Unless Proper Handling Taking Over Signed . , Logsheet / Log Book Of Ht / Lt Shut Down Mes / Mgvcl And Running Of Dg Set Handling / Taking Over Register , Attendance Register , Will Be Maintained Properly And Form Will Be Issued And Printed Form By The Contractor . , A Record Should Be Maintained For Ht Pannel On Standard Mes Type Format ( I . E Logsheet ) Will By Provided By The Contractor W / O Any Extra Cost . , Logsheet / Logbook Of Plant Running And Running Of Dg Set Handing / Taking Over Register , Attendance Register Shall Be Maintained Proper And From Will Be Issued And Printed Form By The Contractor . , Installation And Complex Should Be Kept Clean And Tidy In Presentable Look , Otherwise A Recovery At The Double Rate Of The Quoted Will Be Charged If The Installation And Complex Are Not Kept Cleaned At The Time . , They Shall Carry Out Normal Maintenance Of Gen Set Such As Checking Oil Level Cleaning Of Terminals And Charging Of Battery Tightening Of Nuts And Bolts Greasing Of Manning Parts , Applying Petroleum Galley To Battery Terminals Pouring Distilled Water In Gen Set Etc . , T & P Such As Torch Light , Spanners , Screw Drivers , Cotton Waste Will Be Issued To The Operator By The Contractor Without Any Extra Cost . , Tradesmen Shall Take Preventive Measure And Will Use Protective Clothing As Per Code Of Practice Of Ie Rules And Department Will Not Be Responsible For Any Type Of On Towards Incidents . , Any Negligence Of Duty During Operation Of Gen Set / Switches Off Maintaining Records Will Be Taken Seriously And Compensation Will Be Made As Per Contract Procedures . , Contractor Shall Ensure That No Trade Men Shall Work More Than 48 Hrs In A Weak . , Contractor Shall Provide Life Insurance Of Min 1 Lac To All The Employed Manpower & Copy Of Life Insurance Shall Be Deposited With Department Within One Month Of Acceptance . , No One Absent On Duty , If Any One Found Absent A Recovery At The Double Rate Of The Quoted Will Be Chargable . , The Contractor Also Maintain Daily Log Sheet Shutdown Records And Attendance Registers Regular , Contractor Shall Submit All The Documents Like , Insurance Copy , Educational Qualification , Log Book , Attendance Register , Absentees Register , Epf / Ser Tax Details While Claiming The Pays Of Rars And Final Bill . No Payments Shall Be Entertained By The Dept In The Absence Of The Above Said Documents . , Schedule A Part Ii , Supply , Install , Testing & Commissioning Submersible Openwell Pump 10 Hp Capacity Electric Driven 415 V Three Phase Head 60 Meter At 520 Lmp Discharge , Column Pipe Size 50Mm Bore Bronze Impeller , Graded Cast Iron Pump Bowl Stainless Steel Motor Casing , Stainless Stell Pump Shaft , Stainless Stell Motor Shaft Including Connection With Pump Starter Complete All As Specified And Directed . Make- Crompton / Kirloskar / Lubi , Supply , Install , Testing & Commissioning Submersible Openwell Pump 2 Hp Capacity Electric Driven 220 V Three Phase Head 10 Meter At 520 Lmp Discharge , Column Pipe Size 25Mm Bore Bronze Impeller , Graded Cast Iron Pump Bowl Stainless Steel Motor Casing , Stainless Stell Pump Shaft , Stainless Stell Motor Shaft Including Connection With Pump Starter Complete All As Specified And Directed . Make- Crompton / Kirloskar / Lubi , Supply And Laying Including , Jointing And Testing Exple Insulated Armoured Heavy Duty Electric Cable 16 Sqmm 4 Core With Aluminium Conductor 1100 Volts Grade Cross Sectional Area In Trenches Ducts , Pipe On Wall With Saddling Of Suitable Size Complete All As Specified And Directed . Make- Havells / Anchor / Plaza / Rpg / Hpl / Wipro / Polycab , S&F Star Delta Submersible Pump Starter 10 Hp 415V 3 Phase Complete All As Specified And Directed . Make- Havells India Ltd / Siemens / Larsen & Tubro / Legrand / Hpl / Schneider / Mds / Standard , S&F Dol Submersible Pump Starter 2 Hp 220V Single Phase Complete All As Specified And Directed . Make- Havells India Ltd / Siemens / Larsen & Tubro / Legrand / Hpl / Schneider / Mds / Standard , Supply And Laying Pvc Insulated Flexible Flat Type 3 Core 10 Sqmm Copper Multi Stranded Pvc Sheathed Submersible Cable Sis Marked And Conforming To Is 694 And Connecting To Submersible Pump And Starter Complete All As Specified And Directed . Make- Nicco / Finolex / L&T / Havells / Polycab / Plaza / Anchor / Paragon , S&F Gi Pipe Of 50 Mm Bore Medium Grade With All Fittings Complete All As Specified And Directed . Make- Tata / Jindal / Prakash / Swastik