Military Engineer Services-MES has published Repair And Maintenance Of Summer Appliances And Solar Water Heater At Dronachal Bhopal. Submission Date for this Tender is 16-08-2019. HVAC Tenders in GE Dronachal Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
---|---|---|---|---|---|
1 | 1 | M&L for servicing package type AC plant of 11 TR capacity of make Blue star with greasing of motor bearings, replacement of belts, adjustment of tension of belt, cleaning of all filters, checking of complete wiring, topup of gas (Refrigerant), tightening of nut bolts, oiling and greasing of all movable parts comp[lete all as specified and up the satisfaction of Engr-in-Charge. \n(Note : Cost of belt, Refrigerant gas and lubricant etc required for servicing is deem to be included in unit rate and no extra cost will be paid for this separately).\n\n\n | 6 | Each Job | |
2 | 2 | Replacement of aluminium fan Blade for condensing fan motor of capacity 11TR capacity. | 4 | Each | |
3 | 3 | Replacement of alumium fan blower for cooling fan motor of capacity 11TR capacity. | 4 | Each | |
4 | 4 | Foam type insulating flexible pipe fitted on suction/discharge copper tubes. | 450 | RM | |
5 | 5 | S&F condenser fan motor of ductable type AC of capacity 11 TR as per existing make and model Complete all as directed by Engineer-in-Charge. | 2 | EACH | |
6 | 6 | S&F cooling fan motor of ductable split type as per existing make and model of capacity 11 TR Complete all as directed by Engineer-in-Charge. | 2 | EACH | |
7 | 7 | S & F in repairs wiring kit of package type AC plant of 11 TR capacity complete with lugs, thimble and selector switch, complete all as directed. | 2 | EACH SET | |
8 | 8 | S & F in repairs starting/running capacitor, suitable for ductable type AC of capacity 11 TR. Complete all as directed. | 6 | EACH | |
9 | 9 | Disconnecting Dismentalling and removing of U/S condensor unit coil and S/F in replecement of condensor coil unit including conection of copper tubing for of ductable type AC 11 TR capacity all as directed. . | 1 | EACH | |
10 | 10 | Disconnecting dismentalling and removing of U/S cooling coil from indoor unit complete and supplying and fixing of new indoor cooling coil unit of ductable type AC of capacity of 11 TR, including connection of copper tubing all as directed. | 1 | EACH | |
11 | 11 | S&F in repaired Rotary type Compressor of package type AC plant of 5.5 TR capacity with starting and running capacity and relay including connection of coppertubing and topping up of refrigerant gas for smooth functioning ,complete all as directed. | 6 | EACH | |
12 | 12 | Supply and topping up of Refrigerant gas R 22 in air conditioner at different site as required including brazing and removal of leakage in equipment | 100 | KG | |
13 | 13 | M & L for wall mounted Stablizer of capacity 2 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. | 15 | EACH | |
14 | 14 | M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. | 10 | EACH JOB | |
15 | 15 | S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 11 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. | 4 | EACH | |
16 | 16 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 4.0 sqmm and 1 x 2.5 sqmm for earth wire including taking down old wiring all as directed. | 400 | RM | |
17 | 17 | Supply & fixing single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 32 Amps | 20 | EACH | |
18 | 18 | M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning. Complete all as directed by Engineer-in-Charge. | 4 | EACH JOB | |
19 | 19 | S&F in repairs aluminium fan blade suitable for condenser of window type AC of any capacity. | 1 | EACH | |
20 | 20 | S&F in repairs PVC fan blower of cooling side of window type AC of any capacity. | 1 | EACH | |
21 | 21 | S & F in repairs wiring kit of window type AC complete with lugs, thimble and selector switch, complete all as directed. | 1 | EACH SET | |
22 | 22 | S&F for motor for window type AC of 1.5/2 TR capacity, Complete all as directed by Engineer-in-Charge. | 2 | EACH JOB | |
23 | 23 | M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge. | 40 | EACH JOB | |
24 | 24 | Replacement of Blade for condensing fan motor Split type AC :- | 5 | Each | |
25 | 25 | Capacitor 45 Mfd | 10 | EACH | |
26 | 26 | Capacitor 6 Mfd | 10 | EACH | |
27 | 27 | Capacitor 2.5 Mfd | 10 | EACH | |
28 | 28 | S & F in repairs running capacitor, 36 Mfd suitable for AC of capacity 1.5 TR. Complete all as directed. | 15 | EACH | |
29 | 29 | S & F in repairs starting capacitor, 100-120 Mfd suitable for AC of capacity 1.5 TR. Complete all as directed. | 15 | EACH | |
30 | 30 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC,and S&F the same complete all as directed by Engr-in-Charge. | 10 | EACH JOB | |
31 | 31 | S&F of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR. Complete all as directed. | 5 | EACH JOB | |
32 | 32 | M & L for removing the unserviciable compressor sealed unit of any make from water cooler 40/80 ltr after cutting copper tubing without any damage to existing part ,replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc, jointing of copper copper refrigerent pipe line charging gas to required level , complete including cleaning of fins, leakage testing etc including testing for smooth functioning. complete all as directed by engr in charge. | 4 | EACH JOB | |
33 | 33 | All as per item No. 32 above but compressor of water cooler of capacity 60/120 ltrs. | 4 | EACH JOB | |
34 | 34 | M & L for removing the unserviceable compressor sealed unit of any make from window/split type AC of capacity 1.5 TR after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc. jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning. Complete all as directed by Engineer-in-Charge. | 10 | EACH | |
35 | 35 | Al as per item No. 34 above but for window/split type AC 2 TR capacity. | 5 | EACH | |
36 | 36 | S&F in repaired Compressor for Deepfrizer capacity 200/400 ltr with relay and thermostat complete after desmantalling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level all as directed . | 2 | EACH | |
37 | 37 | S&F in repairs aluminium fan blade for water cooler | 5 | EACH | |
38 | 38 | S&F in repairs thermostat suitable for water cooler of any capacity. | 5 | EACH | |
39 | 39 | S&F in repairs waste water tray, stainless steel with coupling suitable for water cooler of capacity 40/80 ltrs. Complete all as directed | 3 | EACH | |
40 | 40 | S & F PVC drain out flexible pipe of 20mm dia 70 cms length with two mild steel clamps and necessary brass screws etc for water cooler of any size complete all as directed | 10 | EACH | |
41 | 41 | S & F in replacement push cock 15mm bore made out of brass chromium plated self closing vertical type complete all as directed | 10 | EACH | |
42 | 42 | M & L for repair for cutting and removing unserviceable freezer unit of refrigerator capacity 165/170/175 ltrs of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerator gas and testing for smooth functioning. Complete all as directed. | 2 | EACH JOB | |
43 | 43 | S & F in repairs of bulb for pin/screw type 230 Volts suitable for refrigerator 175 to 310 ltrs capacity | 6 | EACH | |
44 | 44 | M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamel spray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. Complete all as directed by Engr-in-Charge. | 100 | EACH JOB | |
45 | 45 | S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc. | 150 | RM | |
46 | 46 | S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolers. | 50 | EACH | |
47 | 47 | S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as directed . | 120 | SET | |
48 | 48 | S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers. | 50 | EACH | |
49 | 49 | S&F repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolers. | 200 | RM | |
50 | 50 | S&F in repairs capacitor 4 Mfd for fan motors of desert coolers. | 100 | EACH | |
51 | 51 | S& F in repairs Sub merrgible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed.Make Crompton/ Khaitan | 100 | EACH | |
52 | 52 | S & F in repairs side shutter (set of three) made out from 24 guagethick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as directed. | 5 | SET OF THREE | |
53 | 53 | S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142gm/each. Complete all as directed. | 25 | EACH | |
54 | 54 | S & F in repairs Aluminium fan blade for fan motor of desert cooler 20 inch sweep. | 100 | EACH | |
55 | 55 | S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/screws all as directed. | 50 | EACH | |
56 | 56 | M & L for oiling of desert cooler fan motor and pump motor complete all as directed. | 30 | EACH JOB | |
57 | 57 | S & F in replacement of desert cooler body complete suitable for 4000 Cum/hr as per sample and as directed. | 3 | EACH | |
58 | 58 | S & F desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed. | 50 | EACH | |
59 | 59 | Supply and topping up of Refrigerant gas R 134 in refrigerators/Deep freezers at different site as required including brazing and removal of leakage in equipment | 50 | JOB | |
60 | 60 | M&L for servicing/cleaning of solar water heating system of capacity 100/200/300 LPD evacuated tube collector/flate panel type incl water supply connection,electric supply connection,electric heating backup with minor defect of Electrical wiring heater, cold water storage tank and necessary fitting complete all as specified and directed by Engr-in-Charge. | 30 | Each Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail