Constructing Two Class Room School Building ( R . C . C ) At Vijaynagar , Tal . Karad . Dist . Satara . , Constructing Two Class room School building (R.C.-Maharashtra

Rural Development Department has published Constructing Two Class Room School Building ( R . C . C ) At Vijaynagar , Tal . Karad . Dist . Satara . . Submission Date for this Tender is 11-08-2019. Building Work Tenders in Constructing Two Class room School building (R.C. Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

21186153
Constructing Two Class Room School Building ( R . C . C ) At Vijaynagar , Tal . Karad . Dist . Satara .
Tender
Indian
Maharashtra
Constructing Two Class Room School Building (R.C.
11-08-2019

Tender Details

Constructing Two Class Room School Building ( R . C . C ) At Vijaynagar , Tal . Karad . Dist . Satara . , Excavation For Foundation In Earth , Soil Of All Types , Sand , Gravel And Soft Murum , Including Removing The Excavated Material Beyond The Building Area And Stacking And Spreading As Directed , Dewatering , Preparing The Bed For The Foundation And Necessary Back Filling , Ramming , Watering Including Shoring And Strutting For All Leads And Lifts Excetra Complete . Item / Page No : 2 / 187Specification No : Bd . A . 1Spec . Page No : 259 , Excavation For Foundation In Hard Murum Including Removing The Excavated Material Beyond The Building Area And Stacking And Spreading As Directed , Dewatering , Preparing The Bed For The Foundation And Necessary Back Filling , Ramming , Watering Including Shoring And Strutting For All Leads And Lifts Excetra Complete . Item / Page No : 6 / 187Specification No : Bd . A . 2Spec . Page No : 259 , Providing And Laying Cast In Situ/Ready Mix , Cement Concrete In M-10 Of Trap/ Granite/ Quartzite/ Gneiss Metal For Foundation And Bedding Including Bailling Out Water , Formwork , Laying/Pumping , Compacting And Curing Excetra Complete , With Fully Automatic Micro Processor Based Programmable Logic Control With Supervisory Control And Data Acquisition Enabled Reversible Drum Type Mixer . - With Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc ) Item / Page No : 1 / 217Specification No : Bd . E . 1Spec . Page No : 287-288Additional Specifications : With Additional Specifications For Controlled Concrete . , Providing And Laying In Situ/Ready Mix Cement Concrete M-20 Of Trap Metal For Reinforced Cement Concrete Work In Foundations Like Raft , Strip Foundations , Grillage And Footings Of Reinforced Cement Concrete Columns And Steel Stanchions , Excetra Including Bailling Out Water , Formwork , Cover Blocks , Compaction , Curing And Roughening The Surface If Special Finish Is To Be Provided ( Excluding Reinforcement And Structural Steel ) , Excetra Complete , With Fully Automatic Micro Processor Based Programmable Logic Controller With Supervisory Control And Data Aquisition Enabled Reversible Drum Type Mixer/ Concrete Batch Mix Plant ( Pan Mixer ) Excetra Complete . With Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc ) Item / Page No : 11 / 222Specification No : Bd . F . 3 , B-7Spec . Page No : 298 , 38-40Additional Specifications : With Additional Specification For Controlled Concrete . , Providing And Laying Cast In Situ / Ready Mix Cement Conrete M-20 Of Trap / Granite /Quartzite/ Gneiss Metal For Reinforced Cement Concrete Columns As Per Detailed Designs And Drawing Or As Directed , Including Steel Centering , Formwork , Cover Blocks , Aying/Pumping , Compaction , Finishing The Formed Surfaces With Cement Mortar 1:3 Of Sufficient Minimum Thickness To Give A Smooth And Even Surface Or Roughening The Surface If Special Finish Is To Be Provided And Curing , Etc . Complete . ( Excluding Reinforcement And Structural Steel ) . With Fully Automatic Micro Processor Based Programmable Logic Controller With Supervisory Control And Data Aquisition Enabled Reversible Drum Type Mixer/ Concrete Batch Mix Plant ( Pan Mixer ) Etc . Complete . With Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc ) ( For Ground Floor ) Item / Page No : 31 / 224Specification No : Bd . F . 5 , B-7Spec . Page No : 300 , 38-40Additional Specifications : With Additional Specification For Controlled Concrete . , Providing And Laying Cast In Situ / Ready Mix Cement Concrete M-20 Of Trap / Granite /Quartzite/ Gneiss Metal For Reinforced Cement Concrete Beams And Lintels As Per Detailed Designs And Drawings Or As Directed Including Steel Centering , Formwork , Cover Blocks , Laying/Pumping , Compaction And Roughening The Surface If Special Finish Is To Be Provided And Curing Complete . ( Excluding Reinforcement And Structural Steel ) . With Fully Automatic Micro Processor Based Programmable Logic Controller With Supervisory Control And Data Aquisition Enabled Reversible Drum Type Mixer/ Concrete Batch Mix Plant ( Pan Mixer ) Excetra Complete . With Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc ) ( For Ground Floor ) Item / Page No : 50 / 225Specification No : Bd . F . 6 , B-7Spec . Page No : 300-301 , 38-40Additional Specifications : With Additional Specification For Controlled Concrete . , Providing Second Class Burnt Brick Masonry With Conventional / Indian Standard Type Bricks In Cement Mortar 1:6 In Foundations And Plinth Of Inner Walls / In Plinth External Of Walls Including Bailling Out Water Manually , Striking Joints , On Unexposed Faces , Racking Out Joints On Exposed Faces And Watering Complete . Item / Page No : 1 / 246Specification No : Bd . G . 1Spec . Page No : 313 , Filling In Plinth And Floors With Approved Excavated Materials In 15 Centimetre To 20 Centimetre Layers Including Watering And Compacting , Excetra Complete . Item / Page No : 36 / 191Specification No : Bd . A . 10Spec . Page No : 262-263 , Filling In Plinth And Floors With Contractors Material / Brought From Outside And Approved By Engineer In-Charge , In 15 Centimetre To 20 Centimetre Layers Including Watering And Compation Excetra Complete . Item / Page No : 37 / 191Specification No : Bd . A . 11Spec . Page No : 263-264 , Providing And Laying 125 Micron Low Density Polyethylene Sheet Confirming To Indian Standard : 3395 - 1997 Below Concrete Pavement Including All Materials And Labour Complete . Item / Page No : 19 / 55Specification No : Morth 605Spec . Page No : --- , Providing And Laying Cast In Situ / Ready Mix Cement Concrete M-20 Of Trap/ Granite / Quartzite/ Gneiss Metal For Reinforced Cement Concrete Slabs And Landings As Per Detailed Designs And Drawings Including Steel Centering , Formwork , Cover Blocks , Laying / Pumping , Compaction , Finishing The Formed Surfaces With Cement Mortar 1:3 Of Sufficient Minimum Thickness To Give A Smooth And Even Surface Or Roughening The Surface If Special Finish Is To Be Provided And Curing , Excetra Complete . ( Excluding Reinforcement And Structural Steel ) . With Fully Automatic Micro Processor Based Programmable Logic Controller With Supervisory Control And Data Aquisition Enabled Reversible Drum Type Mixer/ Concrete Batch Mix Plant ( Pan Mixer ) Excetra Complete . With Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc ) ( For Ground Floor ) Item / Page No : 70 / 227Specification No : Bd . F . 8 , B-7Spec . Page No : 302-303 , 38-40Additional Specifications : With Additional Specification For Controlled Concrete . , Providing And Laying Cast In Situ / Ready Mix Cement Concrete M-20 Of Trap Metal For Reinforced Cement Concrete Chajja As Per Detailed Design And Drawings Including Centering , Formwork , Cover Blocks , Compacting , Finishing And Roughening The Surface If Special Finish Is To Be Provided And Curing Complete . ( Excluding Reinforcement And Structural Steel ) . With Fully Automatic Micro Processor Based Programmable Logic Controller With Supervisory Control And Data Aquisition Enabled Reversible Drum Type Mixer/ Concrete Batch Mix Plant ( Pan Mixer ) Excetra Complete . With Natural Sand/V . S . I . Quality Artificial Sand ( For Ground Floor ) Item / Page No : 5 / 230Specification No : Bdf-9 , B-7Spec . Page No : 303-304 , 38-40Additional Specifications : With Additional Specification For Controlled Concrete . , Providing And Fixing In Position Thermo Mechnically Treated Fe-500 Bar Reinforcements Of Various Dias For Reinforced Cement Concrete Pile Caps , Footings , Foundations , Slabs , Beams , Columns , Canopies , Staircases , Newels , Chajjas , Lintels , Pardis , Copings , Fins , A

Key Value

Document Fees
INR 500 /-
Tender Value
INR 12.40 Lakhs /-