| 1 | 1.01 | Earth work excavation for foundation in all kinds of soils invarying depths including dismantling any masonry or roots met with in foundation shoriEarth work excavation for foundation in all kinds of soils invarying depths including dismantling any masonry or roots met with in foundation shoring with planks and bailing water if necessary, clearing levelling the site with initial lead and including refilling the sides with excavated earth etc. complete | | 25 | CUM |
| 2 | 1.02 | Supplying clean river sand and filling in regular layers of 15cm thick each including watering consolidating etc. completefor foundation basement etc. | | 20 | CUM |
| 3 | 1.03 | Supplying and filling with earth up to 20 Km. for foundation and basement,etc.,including watering and consolidating,etc.,complete | | 30 | CUM |
| 4 | 1.04 | Cement concrete work 1:4:8 (1 cement 4 river sand and 8 blue granite broken stone jelly 40mm gauge) including consolidation curing etc. complete for foundation etc. upto basement | | 20 | CUM |
| 5 | 1.05 | Granolithic flooring 25mm thick with cement concrete 1:2:4 (1cement 2 parts of crushed stone sand and 4 blue granite broken stone jelly 3 to10mm gauge) and top rendered smooth with cement at 10kg per10sq.m. including thread lining curing providing 25mm diaG.I.Pipe of necessary length for water outlet etc. complete asdirected during execution. (The crushed stone sand to be ued on concrete work shall conform to gradation as per IS 383 1970 and the crushed stone sand to be used for mortar shall conform to IS 1542 1977) | | 100 | SQM |
| 6 | 1.06 | Brick work using country bricks 8 3/4\"x4 1/4\"x2 3/4\" in cement mortar1:4 (1 cement and 4 river sand) for walls including curing etc. complete upto basement.(upto 1m high above G.L. | | 50 | CUM |
| 7 | 1.07 | Plastering with cement mortar 1:3 (1 cement and 3 river sand) 12mm thick including curing etc. complete. | | 250 | SQM |
| 8 | 1.08 | White washing one coat over a new plastered surface.. | | 250 | SQM |
| 9 | 1.09 | Colour washing two coats over new plastered surface.. | | 250 | SQM |
| 10 | 1.1 | Roofing with galvanised corrugated iron sheets (thickness of sheet 0.8mm) including J bolts and nuts with bitumen washers etc. complete (ISI STD).. | | 200 | SQM |
| 11 | 1.11 | Supplying and Jointing 25mm dia PVC pipe.including cutting threading and jointing with necessary specials fixing towall with clamps and screws including making holes in the wall ordrilling holes in roof and making good the wall or roof after fixing with necessary scaffolding etc. complete. | | 70 | MTR |
| 12 | 1.12 | Supplying and erecting in position LIGHT DUTY STEEL TRUSSES as per the drawing. The materials and design of the trusses should confirm to the relevant Indian Standard specification. The trusses shall be procured only from reputed manufactures of trusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design. The rate quoted shall include the cost of trusses. Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of redoxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc., The roof sheeting shall project 0.762m from the eves purlins. For structures like CYCLE STAND, PARKING GARAGE, TEMPORARY ENCLOSERS | | 4000 | KGS |
| 13 | 1.13 | Construction of septic tank of standard size 2.3mx1.10mx1.80m for 20 persons capable of cleaning once in 2 years with seepage pit of size 2.5mx3.4m (including free board) including earth work excavation concrete 1:2:4 mix brick work in C.M.1:5 baffle wall R.C.C. removable slab plastering with C.M. 1:3 12mm thick with necessary ventilating Column 75mm dia stoneware pipe and Tees of 100mm dia etc. complete (M.D.53). | | 2 | NOS |
| 14 | 1.14 | Boring using power rig 125mm dia upto hard formation and boring 100mm dia below this in rock formation. the entire column to be cleaned at site as directed including hire charges for the power rig for drilling the bore as described above both upto hard formation and then in rock formation (including the cost of fuel charges transporting to and from the power rig etc. complete.) including flushing the bore using compressor for a minimum time of 12 hours etc. complete providing the danger lights during night time etc. complete as directed during execution. | | 50 | MTR |
| 15 | 1.15 | Supplying and lowering PVC pipe 125mm dia plain casing pipe of 6kg/sq.cm. ISI Std. | | 50 | MTR |
| 16 | 1.16 | Supplying and Jointing 40mm dia P.V.C pipe.includingcutting threading and jointing with necessary specials fixing towall with clamps and screws including making holes in the wall ordrilling holes in roof and making good the wall or roof afterfixing with necessary scaffolding etc. complete. | | 50 | MTR |
| 17 | 1.17 | Supply and fixng of TNEB Moter Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2\" x 1 1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete | | 1 | SET |
| 18 | 1.18 | MCB ISOLATORS OF REPUTED MAKE WITH I.S.I MARK63A F.P | | 1 | NOS |
| 19 | 1.19 | I.SI.MARKED 31/2X35 SQ.MM UNDER GROUND ELECTRIC ALU. CABLE | | 35 | MTR |
| 20 | 1.2 | 63 Amps TPN Metal clad switch with rewirable fuse units. (side Handle) | | 1 | NOS |
| 21 | 1.21 | 16 Amps TPN Metal clad switch with rewirable fuse units. (side Handle) | | 1 | NOS |
| 22 | 1.22 | 101 / 0.45 (16 sqmm)PVC INSULATED SINGLE CORE MULTI STRAND FIRE RETARDANT FLEXIBLE COPPER CABLE WITH ISI MARK CONFORMING TO IS:694/1990 | | 35 | MTR |
| 23 | 1.23 | Supplying and fixing wire fencing with concrete posts. The RCCposts will be 2.2m height (1.75m above ground level) 125mm sq.atbottom and 75mm sq.at top in RCC 1:2:4 mix with necessaryreinforcement moulding work and rendering smooth with cement at15kg/cu.m.etc. complete and embedded in stone jelly concrete 40mmsize in cement mortar 1:4:8 of 45x45x45cm with sand filling 15cmheight. The barbed wire fencing of 5 rows horizontally and 7 rowsvertically. The RCC posts will be at 2.5m. c/c and the barbedwire will be of 2 ply and 12 gauge etc. as directed duringexecution.(ISI STD). | | 110 | MTR |
| 24 | 1.24 | Painting new iron work two coats with ready mixed paint with relevent ISI STD of superior quality and approved colour.. | | 65 | SQM |
| 25 | 1.25 | Electrical work | | 1 | LS |
| 26 | 1.26 | 2 HP MOTOR | | 1 | LS |
| 27 | 1.27 | Supply and Installation of BioShredding Machine(20 HP Motor) | | 1 | LS |
| 28 | 1.28 | Supply and Installation of Manure Seiver Machine (1 HP Motor) | | 1 | LS |
| 29 | 1.29 | Weighing Machine (upto 150Kg) | | 1 | LS |
| 30 | 1.3 | Laying foundation work of BioShredding Pulverizer Machine and Manure seiver Machine | | 1 | LS |
| 31 | 1.31 | supplying and fixing weld mesh | | 44 | SQ.MTRS |