TDR : 56584068
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Bharuch, Gujarat

Tender For Tender for Bi- Annual Rate Contract for Emergency Power Restoration Work of 400/220/132/66kV lines under Bharuch Transmission Circle

Published: 21 Jul 2026
Opening: Ref Document
Closing: 11 Aug 2026
Amount: 48.98 Lakhs
EMD: 48985
Tender Fee: 1180


Works Bio Gas Plant Diesel Power Plants Electrical Substation Gas Power Plants Geothermal Power Plants
10
Days Left
Tender Summary / Eligibility Criteria
Tender for Bi- Annual Rate Contract for Emergency Power Restoration Work of 400/220/132/66kV lines under Bharuch Transmission Circle
Documents Download All
62f6476ecbd646e7905fa3a6bd8805c3
62f6476ecbd646e7905fa3a6bd8805c3.html
E135TenderBharuch
E135TenderBharuch.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9158248 Rate Contract For Preventive / Routine / Breakdown Maintenance / Emergency Restoration Works / Other Works Under Various Heads Of Various Grid Sub Stations And Transmission Lines Under Jurisdiction Of Tlmd-Iii Udhampur
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 8735951 tender for Stage Contract for Annual Maintenance of Transmission Lines in the Jurisdiction of Sub Div-Ist & Civil , transmission lines , checking and tightening of jumpers ( rate shall be per jumper ) , replacement of burnt/ damaged jumpers ( rate shall be per jumper ) including cost of material , replacement of damaged disc insulators , tension string ( rate shall be per disc . ) , suspension string ( rate shall be per disc . ) , repairing of power conductor when lowering of conductor is necessary . complete job including laying of conductor , making of compression joint , if any , rough sagging tensioning of conductor , fixing dead end assembly etc . upto span of 500 meter tension ( rates shall be per span per phase ) , fixing of repair sleeves compression type for acsr panther /zebra conductor including cost of material ( rate shall be per sleeve ) , making mid span compression joint including cost of material ( rates shall be per joint ) , tightening of nuts and bolts of tower superstructures rates shall be per tower , tower weight upto 4 mt , tower weight more than 4 mt upto 7 . 5 mt , tower weight more than 7 . 5 mt , providing & fixing of missing gi lattice members , bolts , nuts & washers if any for tower superstructures , checking / tightening of tower footing earthing bolts and measuring tower footing resistance ( rate shall be per tower ) , branch cutting: in a corridor width of 15 meter for 132kv d/c , branch cutting: in a corridor width of 30 meter for 220kv d/c , repairing damaged conductor by using helikal sleeve or bolted or by shorting method without lowering the conductor ( rate shall be per span per phase ) , repairing / re-fixing of anti climbing devices per tower , providing & fixing of anti climbing devices per tower , fixing of phase plates/ no . plates/ danger plates per d/c tower rates shall be per tower , providing of vehicles including pol for meeting urgent field services viz . fault locating , rectification and restoration of power supply including shifting of restoration teams along with requisite t&p items . ( rates shall be per km of journey )
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9209614 Rate Contract For Preventive / Routine / Breakdown Maintenance Of Components For Various Transmission Lines Falling Under The Jurisdiction Of Tlmd-Viii, Jkptcl, Jammu For The Year 2023-24.- 1 Transmission Line S / C And D / C :- ( Including Carriage Of T&P From Stores And Shutdown Factor ) 2 Break-Down Work ( Emergency Works ) For 132Kv Lines 3 Jumpers ( Replacement Of Burnt / Damaged Jumpers And Tightening Of Remaining Jumpers On The Same Tower ) 4 Disc Insulators ( Replacement Of Damaged Disc Insulators ) 5 Tension String 6 Suspension String 7 Power Conductor 8 Restoration Of Snapped Power Conductor. Complete Job Including Mid-Span Compression Joint, Laying Of Conductor, Rough Sagging, Tensioning Of Conductor Dead-End Assembly Etc. Upto Span Of 500 Metre Tension To Tension Point 9 Earth Wire 10 Restoration Of Snapped Earthwire Complete Job Including Mid-Span Compression Joint, Laying Of Conductor, Rough Sagging, Tensioning Of Earthwire, Dead-End Assembly Etc. Upto Span Length Of 500 Metre Tension To Tension Point 11 Planned Works 12 Checking And Tightening Of Jumpers ( Per Ckt With 6 Jumpers ) 13 Checking And Tightening Of Jumpers ( Per Ckt With 3 Jumpers ) 14 Replacement Of Damaged / Burnt Out Jumpers 15 Fixing Of Damper / Vibrator On Earthwire / Acsr Conductor 16 Replacement Of Damaged Disc Insulators 17 Tension String 18 Suspension String 19 Repairing Of Power Conductor When Lowering Of Conductor Is Necessary. Complete Job Including Laying Of Conductor, Making Of Compression Joint, If Any, Rough Sagging Tensioning Of Conductor, Fixing Dead End Assembly Etc. Upto Span Of 500 Meter Tension 20 Stringing And Saging Of Acsrconductor Including Sagging, Tensioning, Fitting Of Dead End Assamblies Etc. ( Complete Job ) 21 Repairing Of Ground Wire When Lowering Of Conductor Is Necessary. Complete Job Including Laying Of Conductor, Making Of Compression Joint, If Any, Rough Sagging Tensioning Of Conductor, Fixing Dead End Assembly Etc. Upto Span Of 500 Meter Tension 22 Stringing And Saging Of Ground Wire Including Sagging, Tensioning, Fitting Of Dead End Assamblies Etc. ( Complete Job ) 23 Tower S / C And D / C:- ( Including Carriage Of T&P From Stores And Shutdown Factor ) 24 Foundation:-Repairing Of Damaged Foundation And Protection Wall ( Revetment ) Including Back Filling Of Earthwith Rcc Concreating. 25 Provision Of Providing Crate Wall ( Gabbon Wall ) 26 Tightening Of Nuts And Bolts Of Tower Superstructures Replacement Of Missing Ones. 27 A ) Tower Weight More Than 4 Tonnes To 7.5 Tonnes 28 B ) Tower Weight More Than 7.5 Tonnes 29 Checking / Tightening Of Tower Footing Earthing Bolts And Measuring Tower Footing Resistance. 30 Earthing Of Towers Inclusive Of Material ( Earthing Rod, Strips, Good Earth Etc ) 31 Normal Type ( Rates Inclusive Of Material ) 32 Counterpoise ( Rates Inclusive Of Material ) 33 Branch Cutting: Under The Coridor Of 132 Kv S / C And D / C Transmission Line 16 Mtrand Under Tower Structure 34 Making Of Approach Path Towards The Tower 35 Deweeding Of The Area Under The Tower 36 Replacement Of Missing Tower Members. 37 Reparing Damaged Conductor By Using Helical Sleeve Or Bolted Or By Shorting Method With Out Lowering. The Conductor 38 Fixing Of Anti-Climbing Device / Bird Guardover S / C &D / C Tower 39 Fixing Of Phase Plates / No. Plates / Danger Plates Overs / C & D / C Tower 40 Fixing Of Repair Sleeves Compression Type For Over Acsr Conductor 41 Tag Welding Of Towersfor One Story 42 Dismantling Of Towers 43 A Type 44 B Type 45 C Type 46 D Type 47 Earth Work Of Towers Including Material 48 Lean Pad ( Rates Inclusive Of Material ) 49 Rrm ( Rates Inclusive Of Material ) 50 Dpc ( Rates Inclusive Of Material ) 51 Providing Of Skilled / Semi-Skilled / Unskilled Labour For The Works Which Are Not Covered From S.No. 1 To 1.35 52 Skilled Labour ( Rigger ) 53 Semi-Skilled Labour ( Asstt. Fitter ) 54 Unskilled Labour 55 Store Handling: 56 Unloading / Loading Oft&P Material For Transmission Line Works Including Four Sheaves Pulley, Pulleys, Ropes, Compression Machine Etc In Divisional Stores Gladni Including Manual Carriage Within Store Yard. 57 Unloading / Loading Ofcement In Divisional Store Gladni Including Manual Carriage Within Store Yard ) . 58 Unloading / Loading Ofdisc Insulators / Fittings In Divisional Store Gladni Including Manual Carriage Within Store Yard ) . 59 Unloading / Loading Of Conductor / Earth Wire, Etc In Divisional Store Gladni Including Manual Carriage Within Store Yard ) . 60 Carriage Of T&P And Other Allied Material From Divisional Store To Site Of Work And Back Carriage Of T&P And Material
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 8782135 Rate Contract For Preventive/ Routine/ Breakdown Maintenance Of Components For 132 Kv Barn Canal Tl , 132 Kv Gladni Janipur Tl , 132Kv Barn Katra Tl , 132 Kv Rajouri Draba Tl , 132 Kv Barn Jourian Tl , 132 Kv Kt Line , 132 Kv Kalakot Rajouri Tl For 2020-21 , Transmission Line S/C And D/C :- ( Including Carriage Of T&P From Stores And Shutdown Factor ) , Break-Down Work ( Emergency Works ) For 132Kv Lines , Jumpers ( Replacement Of Burnt/Damaged Jumpers And Tightening Of Remaining Jumpers On The Same Tower ) , Disc Insulators ( Replacement Of Damaged Disc Insulators ) , Tension String , Suspension String , Power Conductor , Restoration Of Snapped Power Conductor . Complete Job Including Mid-Span Compression Joint , Laying Of Conductor , Rough Sagging , Tensioning Of Conductor Dead-End Assembly Etc . Upto Span Of 500 Metre Tension To Tension Point , Earth Wire , Restoration Of Snapped Earthwire Complete Job Including Mid-Span Compression Joint , Laying Of Conductor , Rough Sagging , Tensioning Of Earthwire , Dead-End Assembly Etc . Upto Span Length Of 500 Metre Tension To Tension Point , Planned Works , Checking And Tightening Of Jumpers ( Per Ckt With 6 Jumpers ) , Replacement Of Damaged /Burnt Out Jumpers , Fixing Of Damper/Vibrator On Earthwire/Acsr Conductor , Replacement Of Damaged Disc Insulators , Tension String , Suspension String , Repairing Of Power Conductor When Lowering Of Conductor Is Necessary . Complete Job Including Laying Of Conductor , Making Of Compression Joint , If Any , Rough Sagging Tensioning Of Conductor , Fixing Dead End Assembly Etc . Upto Span Of 500 Meter Tension , Stringing And Saging Of Acsr Conductor Including Sagging , Tensioning , Fitting Of Dead End Assamblies Etc . ( Complete Job ) , Repairing Of Ground Wire When Lowering Of Conductor Is Necessary . Complete Job Including Laying Of Conductor , Making Of Compression Joint , If Any , Rough Sagging Tensioning Of Conductor , Fixing Dead End Assembly Etc . Upto Span Of 500 Meter Tension , Stringing And Saging Of Ground Wire Including Sagging , Tensioning , Fitting Of Dead End Assamblies Etc . ( Complete Job ) , Tower S/C And D/C:- ( Including Carriage Of T&P From Stores And Shutdown Factor ) , Foundation:-Repairing Of Damaged Foundation And Protection Wall ( Revetment ) Including Back Filling Of Earth With Rcc Concreating . , Provision Of Providing Crate Wall ( Gabbon Wall ) , Tightening Of Nuts And Bolts Of Tower Superstructures Replacement Of Missing Ones . , A ) Tower Weight More Than 4 Tonnes To 7 . 5 Tonnes , B ) Tower Weight More Than 7 . 5 Tonnes , Checking / Tightening Of Tower Footing Earthing Bolts And Measuring Tower Footing Resistance . , Branch Cutting: Under The Coridor Of 132 Kv S/C And D/C Transmission Line 16 Mtr And Under Tower Structure , Making Of Approach Path Towards The Tower , Deweeding Of The Area Under The Tower , Replacement Of Missing Tower Members . , Reparing Damaged Conductor By Using Helical Sleeve Or Bolted Or By Shorting Method With Out Lowering . The Conductor , Fixing Of Anti-Climbing Device/Bird Guard Over S/C & D/C Tower , Fixing Of Phase Plates/No . Plates/Danger Plates Over S/C & D/C Tower , Fixing Of Repair Sleeves Compression Type For Over Acsr Conductor , Providing Of Skilled /Semi-Skilled / Unskilled Labour For The Works Which Are Not Covered From S . No . 1 To 1 . 35 , Skilled Labour ( Rigger ) , Semi-Skilled Labour ( Asstt . Fitter ) , Unskilled Labour , Store Handling: , Unloading / Loading Of T&P Material For Transmission Line Works Including Four Sheaves Pulley , Pulleys , Ropes , Compression Machine Etc In Divisional Stores Gladni Including Manual Carriage Within Store Yard . , Unloading / Loading Of Cement In Divisional Store Gladni Including Manual Carriage Within Store Yard ) . , Unloading / Loading Of Disc Insulators/Fittings In Divisional Store Gladni Including Manual Carriage Within Store Yard ) . , Unloading / Loading Of Conductor/Control Cable Etc In Divisional Store Gladni Including Manual Carriage Within Store Yard ) . , Carriage Of T&P And Other Allied Material From Divisional Store To Site Of Work And Back Carriage Of T&P And Material , Average Distance Upto 20 Km , Average Distance Upto 40Km , Average Distance Upto 60Km , Average Distance Upto 85Km , Average Distance Upto 150Km , Average Distance Upto 200Km , Average Distance Upto 250Km
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 11677868 Tender for Annual Fixing Of Rate Contract For Supply Of Testing Equipments, Tools And Material Required For Repair/Maintenance/Restoration Of 33Kv Lines And 33/11Kv Receiving Stations Under The Jurisdiction Sub-Transmission Division (Jpdcl) Kalakote For The One Year , Supply Of Items , Smartphone-Compatible Infrared (Thermal) Camera For Hotspot Detection [Reputed Makes:Fluke Isee Tc01a | Infiray P2 Pro| Topdon Tc001 / Tc002| Fluke Isee Tc01a] [Standards: Iec 60825-1 / Ce / Custom Specs] , Digital Total Station With Laser With Bluetooth(Surveying Without Prism/With Prism) Minnimum Configuration Equivalent To Topcon Gm-62 [Reputed Makes: Leica Geosystems, Topcon, Trimble] [Standards: Iso 17123-4 (Is Compliant)] , Digital Earth Resistance Tester (4-Terminal ) [Reputed Makes: Megger, Fluke, Motwane, Waco] [Standards: Is 3043, Iec 61557-5] , Digital Earth Resistance Tester (Clamp Type) [Reputed Makes: Megger, Fluke, Motwane, Waco] [Standards: Is 3043, Iec 61557-5] , Digital Insulation Resistance (Megger) Tester 5Kv/10Kv With Pi Calculation [Reputed Makes: Megger, Fluke, Motwane] [Standards: Is 2442, Is 10118, Iec 61557-2] , Contact Resistance Meter (Crm - 100A/200A Dc) For Vcb Contacts [Reputed Makes: Megger, Scope T&M, Motwane] [Standards: Iec 62271-1] , Fluke 301E Digital Multimeter (True Rms, Industrial Grade Heavy Duty For Substation Application) [Specifications: 1000V Ac/Dc, 1000A Ac/Dc, Resistance, Capacitance, Frequency, Min/Max/Avg Tracking, Cat Iv 600V / Cat Iii 1000V Safety Rated] [Standards: Is 13875, Iec/En 61010-1] , Edm Bosch Glm 100-25 C Professional Laser Measure, 100M Range, Inbuilt Camera Viewfinder, Ips Display, Bluetooth Connectivity , Cctv System: 1 Nos Full Hd 8 Channel Dvr With 08Nos 2 Mp Outdoor Cameras [Color Night Vision + Built-In Audio Mic + Smart Dual Light + Motion Detection] + 1 Tb Hdd + 8 Ch Smpower Supply +Bnc/Dc Set [Reputed Makes: Cp Plus, Hikvision, Dahua, Matrix Comsec] [Standards: Is 13252 (Part 1)] , Cctv Camera Wire / Cable [Reputed Makes: Finolex, Polycab, Havells, repair renovation Kabel] [Standards: Is 694, Is 1554] , 32 Led 4K Smart Tv With Hdmi Cables For Monitoring / Control Room Display [Reputed Makes: Sony, Samsung, Lg, Panasonic] [Standards: Is 616 / Iec 60065] , Laptop For Sub-Division Engineering & Data Maintenance Minimum Configuration- (I5 13 Gen | 16Gb Ram | 512Gb Ssd | Windows 11 Home | Ms-Office | Fhd Or Higher) [Reputed Makes: Dell, Hp, Acer, Lenovo, Apple] [Standards: Is 13252 (Part 1)] , All In One/ Standard Desktop Computer System With Standard Peripherals Minimum Configuration- (I5 13 Gen | 16Gb Ram | 512Gb Ssd | Windows 11 Home | Ms-Office | Fhd) [Reputed Makes: Dell, Hp, Acer, Lenovo] [Standards: Is 13252 (Part 1)] , Wired Optical Usb Mouse (Heavy Duty Ergonomic Office Mouse) [Reputed Makes: Logitech, Hp, Dell, Lenovo] , Wired Standard Usb Keyboard (Robust Membrane/Mechanical Layout) [Reputed Makes: Logitech, Hp, Dell, Lenovo] [Standards: Is 13252 / Iec 60950] , Ups For Computers (600Va/1Kva Line Interactive Ups For Power Backup) [Reputed Makes: Apc By Schneider, Microtek, Luminous, Cyberpower] [Standards: Is 16242, Is 13252] , 5 Socket Extension Spike Guards (Multi-Plug Surge Protect Boards) [Reputed Makes: Anchor By Panasonic, Havells, Gm, Honeywell] [Standards: Is 1293, Is 60947] , Printer All In One Ink Tank For Office (Coloured Multi-Function Ink Tank Printer With Wifi) (Yield-5000-7000 Pages) [Reputed Makes: Canon, Brother] [Standards: Is 13252] , Printer Ink Bottles Set (Ink Bottle Cartridges For Ink Tank Office Printers) (Yield-5000-7000 Pages) ( Black N 3X Colour [Reputed Makes: Canon, Hp, Epson] [Standards: Is 13252 / Ce / Oem Standard] , Wi-Fi/Wan Router / Lan Network Splitter Switch (Gigabit Rj45 Hub X4) [Reputed Makes: Tp-Link, D-Link, Cisco, Netgear] [Standards: Is 13252 (Part 1)] , Lan Cable With Connectors (Cat6 High-Speed Network Ethernet Cable) [Reputed Makes: D-Link, Finolex, Molex, Polycab] [Standards: Is 16043, Iec 61156] , Steel Tubular Pole (Stp) 13 Meter Long (Designation St-410, Sp-69) [Reputed Makes: Tata Pipes, Utkarsh India, Jindal, Apollo] [Standards: Is 2713 (Part 1 To 3)] , Steel Tubular Pole (Stp) 11 Meter Long (Designation St-410, Sp-56) [Reputed Makes: Tata Pipes, Utkarsh India, Jindal, Apollo] [Standards: Is 2713 (Part 1 To 3)] , Steel Tubular Pole (Stp) 9 Meter Long (Designation St-410, Sp-33) [Reputed Makes: Tata Pipes, Utkarsh India, Jindal, Apollo] [Standards: Is 2713 (Part 1 To 3)] , 33Kv Vacuum Circuit Breaker (Vcb) Outdoor Type [Reputed Makes: Siemens, Schneider Electric, Abb, Cg Power, Megawin, S&S] [Standards: Is/Iec 62271-100] , 33Kv Control & Relay (C&R) Transformer Panel With Differential Protection [Reputed Makes: Abb, Siemens, Schneider Electric, Cg Power, Megawin, S&S] [Standards: Is 3231, Iec 60255] , 33Kv Control & Relay (C&R) Line Panel For Feeder Protection [Reputed Makes: Abb, Siemens, Schneider Electric, Cg Power, Megawin, S&S] [Standards: Is 3231, Iec 60255] , Battery Charger: Automatic (Float & Boost) Compatible For Vrla Batteries [Reputed Makes: Exide, Hbl Power, Statcon Energia, Mass-Tech] [Standards: Is 3895, Is 4540] , 11Kv Vcb Trolley Suitable For Cg, Abb, Electric Field Breakers [Reputed Makes: Abb, Cg Power, Schneider Electric, Siemens] [Standards: Is/Iec 62271-100, Is 13118] , Ms Channel Iron (100X50x6 Mm) [Reputed Makes: Sail, Tata Steel, Jsw, Jindal Steel] [Standards: Is 2062 (Grade E250), Is 808] , Ms Angle Iron (50X50x6 Mm) [Reputed Makes: Sail, Tata Steel, Jsw, Jindal Steel] [Standards: Is 2062, Is 808] , Ms Flat Iron (50X6 Mm) [Reputed Makes: Sail, Tata Steel, Jsw, Jindal Steel] [Standards: Is 2062, Is 1730] , Ms Channel Iron (75X40x6 Mm) [Reputed Makes: Sail, Tata Steel, Jsw, Jindal Steel] [Standards: Is 2062, Is 808] , Ms Angle Iron (40X40x6 Mm) [Reputed Makes: Sail, Tata Steel, Jsw, Jindal Steel] [Standards: Is 2062, Is 808] , Ms Flat Iron (40X6 Mm) [Reputed Makes: Sail, Tata Steel, Jsw, Jindal Steel] [Standards: Is 2062, Is 1730]
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders