BRR : 9898258
Tender Brief : Tender For Repair Maintenance Of Internal Electrical Installation, Fire Fighting, Fire Alarm, Pa System, Dg Set & Operation Of Lift & Ventilation At Community Hall Pkt 20B, Sita Puri As Per Inventory & Terms And Condition Attached By Deploying Following Staff:- A) Operator Grade-Ii- 1 No. In General Shift As And When Required. B) Khallasi- 1 No. Fortnightly As And When Required. C) Wireman Grade-I - 1 No. - Shall Attend The Sites Of Work Between 9:00 A.M. To 5:00 P.M At Least Once In A Fortnight And As And When Required. , Operation & Maintenance Of Internal Electrical Installation,Fire Fight... Read More
Tender Value
₹
14,04,045
Submission Date
24-03-2026
Participated Bidder List
2 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics |
Work Detail
tender for repair maintenance of internal electrical installation, fire fighting, fire alarm, pa system, dg set & operation of lift & ventilation at community hall pkt 20b, sita puri as per inventory & terms and condition attached by deploying following staff:- a) operator grade-ii- 1 no. in general shift as and when required. b) khallasi- 1 no. fortnightly as and when required. c) wireman grade-i - 1 no. - shall attend the sites of work between 9:00 a.m. to 5:00 p.m at least once in a fortnight and as and when required. , operation & maintenance of internal electrical installation,fire fighting ,fire alarm, pa system, dg set & operation of lift at community hall pkt -3, sec-19, dwarka as per inventory & terms and condition attachedby deploying following staff:- a) operator grade-ii- 1 no. in general shift as and when required. b) khallasi- 1 no. fortnightly as and when required. c) wireman grade-i - 1 no. - shall attend the sites of work between 9:00 a.m. to 5:00 p.m at least once in a fortnight and as and when required. , supplying, replacement, testing & commissioning of street light led fixture powder coated pressure die cast aluminum body with driver as per the requirement with driver efficiency 85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency 85%,thd 10% as per iec 61000-3-2 , p. f.≥0.95, ip- 66,ik-10, cri 80, under voltage and over voltage protection, emiemcas per cispr 15 , lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000°k / 4000°k/ 5700°k /6000°k/6500°k (as per ansi bin), sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥105 120 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90°c). powder coated die cast / extruded aluminium body (thickness ≥ 1.20 mm) a) 18- 22 watt 4 ft led batten light (dsr e & m 2025) , supply and replacement of following accessories i/c testing etc complete as reqd. a) 6a to 32 a spn mcb ccurve,10ka breaking capacity , b) sp 15/16 amp, one way switch, piano type isi marked , c) 3 pin 5/6 amp, socket outlet, piano type isi marked , d) 6 pin 15/16 & 5/6 amps, socket outlet, piano type isi marked , e) sp 5/6 amp, one way switch, piano type isi marked , f) stepped type modular fan regulator (2 module) , g)1.5 sq. mm isi marked frls pvc insulated, single core copper conductor cable , h)4 sq. mm isi marked frls pvc insulated ,single core copper conductor cable , servicing of 100 kva dg set( greaves make) i/c supply & replacement of following parts i/c connecction & testing etc.complete as reqd. (for sh-i) i) b check kit - 1 set ii) engine oii -30 ltrs , servicing of 62.5 kva dg set ( greaves make) i/c supply & replacement of following parts i/c connection & testing etc.complete as reqd. (for sh-ii) i) b check kit - 1 set ii) engine oii -20 ltrs , rewinding of 5 h.p. open well pump set, 1 no., water seal 2 nos. bearing bush 4 nos, thrust plate 1 no., thrust bearing 1 no., impeller key 1 no. balancing of rotor 1 no., stamping repairing 1 no., epoxy paint of rotor 1 no., labour charges including cartage testing and commissioning etc. complete as required. , lifting / lowering of submersible pump set with the help of heavy duty t&p skilled man power including making water proof cable jointing, testing etc. complete as required , supplying of high speed diesel for operation of dg set i/c cartage, storage, filling and arrangement of minimum 200 ltrs capacity tank at site in tank etc. complete as required. , overhauling, checking, reconditioning, servicing, greasing of the diesel engine driven fire pump set of 52 hp capacity including necessary repairs, alignment of pump as required and re-testing & commissioning of the same complete as required. the job also includes putting the same in automatic operation mode of the main pump set to make it functional as per delhi fire service requirements. (for sh-i) , overhauling, checking, reconditioning, servicing, greasing of the electric driven main fire hydrant pump set of 50 hp capacity including necessary repairs, alignment of pump as required and re-testing & commissioning of the same complete as required. the job also includes putting the same in automatic operation mode of the main pump set to make it functional as per delhi fire service requirements. (for sh-i) , overhauling, checking, reconditioning, servicing, greasing of the including necessary repairs including alignment of jockey pump set of 7.5 hp capacity as required and re-testing & commissioning of the same complete as required. the job also includes putting the same in automatic operation mode to make it functional as per delhi fire service requirements. (for sh-ii) , overhauling, checking, reconditioning, servicing, greasing of the including necessary repairs including alignment of terrace pump set of 5 hp capacity as required and re-testing & commissioning of the same complete as required. the job also includes putting the same in automatic operation mode to make it functional as per delhi fire service requirements. (for sh-i) , painting of fire fighting all equipments like ms pipes of all size(150mm,100mm,80mm,65mm,50 mm,40mm,32mm & 25 mm dia),fire hydrant boxs,hose cabinets, ms fire shaft doors,ff panels , pumps & motors etc. along with bracket/clamp etc with minimum two coats of synthetic enamel paint of approved brand and manufacture of required shade after cleaning the surface of the same etc. complete as reqd.(civil dsr 2023 item no. 13.99) , reconditioning and making functional of existing agni make fire alarm control panel of 1 zone i/c overhauling checking, servicing,testing & commissioning of the same after effecting necessary repairs/replacement of internal defective parts viz power supply card, zone card, re-wiring i/c re-testing & commissioning etc.complete as required, operating at 24 vdc comprising of audio & visual alarm indication of fire, continuous status indications of health/fire/faulty zones, fire/fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm. silence alarm and a switch for resetting the whole system with audio-visual indications etc as required. the job i/cs checking the entire system tracing and removing the faults in system, denting & painting the fire alarm control panel complete,i/c credit for defective/unserviceable spare parts .etc. complete as required. (for sh-ii) , reconditioning and making functional of existing agni make fire alarm control panel of 4 zone i/c overhauling checking, servicing,testing & commissioning of the same after effecting necessary repairs/replacement of internal defective parts viz power supply card, zone card, re-wiring i/c re-testing & commissioning etc.complete as required, operating at 24 vdc comprising of audio & visual alarm indication of fire, continuous status indications of health/fire/faulty zones, fire/fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm. silence alarm and a switch for resetting the whole system with audio-visual indications etc as required. the job i/cs checking the entire system tracing and removing the faults in system, denting & painting the fire alarm control panel complete,i/c credit for defective/unserviceable spare parts .etc. complete as required.(for sh-i) , supply and replacement of 12 volts 130 ah battery wih initial charging i/c connections, testing etc as reqd.(i/c rebate for old battery) , supllying and replacement of single battery charger 12v suitable upto 150 ah battery i/c connection, testing etc complete as required. , photoluminescent signage 2 mm thick aluminum sheet(12 inch x 6 inch) non toxic non radio active maintenance free self-glowing exit sign or any other fire or emergency signs , comprising zinc sulphide chargeable crystals which glow in dark printed on u-1000 photo-luminescent base chemical cover with u-v stabilized coating which glow in dark. a) single side--4 nos. , b) double side---5 nos. , supplying and replacement of single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal/stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 (type a) with blank gunmetal/stainless steel cap and chain as required (dsr 2025 e & m) : a) single headed stainless steel
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results