BRR : 9749335
Click Here To View Tendering Authority. Aoc City/State :  jodhpur, Rajasthan
Tender Brief : comprehensive maintenance contract For Fire Alarm System And Other Connected Items Installed At Mh Jodhpur And Hq Cejz Under Ge (Army) No. 02 Jodhpur- 1 M&L for Servicing / Maintenance/Cleaning / testing and commissioning of complete Fire Alarm system installed at MH Jodhpur which is consist following items :- (a) Multi smoke /Heat detector - 1824 Nos. (b) Addresable Control/Monitor Module -50 Nos(c) Fire Alarm sounder/speaker - 100 Nos.(d) Response Indicator - 906 Nos.(e) Addresable MCP- 40 Nos (f) Microprocessor based main control panel- 02 Nos.(g) Repeater panel- 06 Nos(h) Main Hooter -01... Read More
Tender Value
25,00,000
Contract Value
₹ 20,68,516
Saving / Difference
₹ 4,31,484 ▲
Submission Date
09-01-2026
Contract Date
06-03-2026
Completion Date
270 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 20,68,516 L1
2 cnet-technologies Bid Analytics 24,26,950 L3
3 cnet-technologies Bid Analytics 22,66,775 L2
Work Detail
comprehensive maintenance contract for fire alarm system and other connected items installed at mh jodhpur and hq cejz under ge (army) no. 02 jodhpur- 1 m&l for servicing / maintenance/cleaning / testing and commissioning of complete fire alarm system installed at mh jodhpur which is consist following items :- (a) multi smoke /heat detector - 1824 nos. (b) addresable control/monitor module -50 nos(c) fire alarm sounder/speaker - 100 nos.(d) response indicator - 906 nos.(e) addresable mcp- 40 nos (f) microprocessor based main control panel- 02 nos.(g) repeater panel- 06 nos(h) main hooter -01 nos and other connected items for their connection i.e. cable and servicing complete all as specified and directed by engineer-in-charge.note:- (i) properly making notes of functional and non functional items for submission to engineer-in-charge (ii) replacement cost of minor part included in above mentioned cost (ii) replacement of unsv items/ parts suitable for fire alarm system shall be paid seperately under respective items. 2 supply, installation, testing, commissioningin replacement analogue addressable type multicriterion smoke detector with sounder base, address switch including taking downold unsvcomplete all as specified and directed by engineer-in-charge. 3 supply, installation, testing, commissioningin replacementanalogue addressable type heatdetector, address switch including taking downold unsvcomplete all as specified and directed by engineer-in-charge. 4 supply, installation, testing, commissioningin replacementanalogue addressable type control/monitor moduleincluding taking downold unsvcomplete all as specified and directed by engineer-in-charge. 5 supply, installation, testing, commissioning in replacementaddressablepull station type manual call points complete with address switchincluding taking downold unsvcomplete all as specified and directed by engineer-in-charge. 6 supply, installation, testing, commissioningin replacementhorn cum strobehoter with addressableswitch complete as requiredincluding taking downold unsvcomplete all as specified and directed by engineer-in-charge. 7 supply, installation,testing, commissioningin replacement addrssable typeloop cardsuitable forupto 250 devices complete all as specified and directed by engineer-in-charge. 8 supply, installation, testing, commissioning in replacement addrssable type power supply includingpower line surge barrier with emi/ref filterincluding taking downold unsvcomplete all as specified and directed by engineer-in-charge. 9 supply, installation, testing, commissioning in replacement addressable type fault isolators for isolating shorted, de-wired and loose circuits between two successive fault isolators with automatic resetting arrangementincluding taking downold unsvcomplete all as specified and directed by engineer-in-charge. 10 supply, installation, testing, commissioningin replacement response indicator consisting of 16 gauge ms box with 75 x 75 x 6 thick cross brushed aluminium face plate for above false ceiling detectors. (for above false ceiling detectors) including taking downold unsv complete all as specified and directed by engineer-in-charge. 11 repair/maintenance,testing, commissioning in replacement addressble network cardaddressable module to connect repater panelwith the addressable panelcomplete all as specified and directed by engineer-in-charge. 12 supply and fixing in replacment maintenance free battery 12 v 7 ah including terminal complete all as specified and directed by engineer-in-charge. 13 supply and laying including termination of 2 core 1.5 sqmm stranded pvc insulated pvc sheathed copper conductor 1100volt grade fire resistant armoured cable including terminations, all labour and material etc. complete (panel to detectors devices, for repeater panels,above false ceiling detectors & response indicator). complete all as specified and directed by engineer-in-charge. 14 supply and fixing 20 mm dia pvc conduit isi marked including all necessary supports, clamps, joining pieces etc for drop of cables from slab to detector. complete all as specified and directed by engineer-in-charge. 15 supplyand fixing 40 x 200 x 40 x 2 mm thick slotted angle stove enamelled cable tray isi marked for fixing on walls including all nuts, bolts, washers etc. for runs of armoured cables. complete al as specified and directed by engr-in-charges. 16 supply and fixing in replacment ups 2kva without in built batteries complete all as specified and directed by engineer-in-charge. 17 m&l for servicing / maintenance / repair/ testing and commissioning of complete fire alarm system installed at hq cejz jodhpur which is consist following items :- (a) multi sensor analog smoke detector - 220 nos.(b) analog heat detector - 17 nos.(c) fire alarm sounder - 20 nos.(d) response indicator - 23 nos.(e) microprocessor based main control panel- 02 nos.(f) repeater panel- 02 nos and other connected items for their connection i.e. cable and servicing complete all as specified and directed by engineer-in-charge.note:- (i) replacement cost of minor part included in above mentioned cost (ii) replacement of unsv items/ parts suitable for fire alarm system shall be paid seperately under respective items.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 9ce6b569-d659-44ce-8da2-a723552c5c96 result notice
Download boqcomparativechart boq document
Download cano125202526 aoc document
Download finance_833127 aoc document
Download finsummary_833127 aoc document
Download technical_833127 aoc document
Download techsummary_833127 aoc document
Download File Name File Description
Download f3ee4215-cf06-4064-885b-1920d07cde17 Tender Documents
Download BOQ_833127 Tender Documents
Download TENDER106 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders