BRR : 9696643
Tender Brief : Supply of Hematology Analyzer 5 Part Model B , Hematology Analyser( 5 Part ) Model B , Please Mention The Cost Of One Test Of Cbc The Cost / Test Calculation Should Be Based On The Following; • Workload: Total Number Of Samples – 100. Out Of Which 75 Samples Are Tested In Between 08.00 A.M. To 01.00 P.M. At Equal Intervals Of Time And Remaining 25 Samples In Between 01.00 P.M. To 08.00 A.M. At Equal Intervals Of Time. • Cost/ One Test = X/ 100 X = The Cost Of All Reagents Required By The Offered Model To Perform Startup (If Any), Shut Down (If Any), Active To Stand By (If Any), Standby To Act... Read More
Tender Value
₹
4,46,798
Submission Date
01-09-2025
Participated Bidder List
8 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics | |||||
| 5 | cnet-technologies | Bid Analytics | |||||
| 6 | cnet-technologies | Bid Analytics | |||||
| 7 | cnet-technologies | Bid Analytics | |||||
| 8 | cnet-technologies | Bid Analytics |
Work Detail
supply of hematology analyzer 5 part model b , hematology analyser( 5 part ) model b , please mention the cost of one test of cbc the cost / test calculation should be based on the following; • workload: total number of samples – 100. out of which 75 samples are tested in between 08.00 a.m. to 01.00 p.m. at equal intervals of time and remaining 25 samples in between 01.00 p.m. to 08.00 a.m. at equal intervals of time. • cost/ one test = x/ 100 x = the cost of all reagents required by the offered model to perform startup (if any), shut down (if any), active to stand by (if any), standby to active (if any), cleaning (if any), calibration (if any) andreagents for 100 sample run. the number of times of the each process required based on the workload and the consumption of reagents should be declared in the offer form, failing which the offer will not be considered. • rate offered must be inclusive of tax. • for l1 calculation the “cost/ one test” offered by the bidders shall be multiplied by 90,000 (100 tests x 25 days x 12 months x 3 years). please note that the calculation shall be done by the boq automatically , please mention the cost of one test of cbc+differential the cost / test calculation should be based on the following; • workload: total number of samples – 100. out of which 75 samples are tested in between 08.00 a.m. to 01.00 p.m. at equal intervals of time and remaining 25 samples in between 01.00 p.m. to 08.00 a.m. at equal intervals of time. • cost/ one test = x/ 100 x = the cost of all reagents required by the offered model to perform startup (if any), shut down (if any), active to stand by (if any), standby to active (if any), cleaning (if any), calibration (if any) andreagents for 100 sample run. the number of times of the each process required based on the workload and the consumption of reagents should be declared in the offer form, failing which the offer will not be considered. • rate offered must be inclusive of tax. • for l1 calculation the “cost/ one test” offered by the bidders shall be multiplied by 90,000 (100 tests x 25 days x 12 months x 3 years). please note that the calculation shall be done by the boq automatically , rate and pack size ofdiluent 1 offered ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns) rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size ofdiluent 2 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here , rate and pack size ofdiluent 3 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here , rate and pack size oflyse 1 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size oflyse 2 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size oflyse 3 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size ofcleaning solution 1 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size ofcleaning solution 2 offered. ( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size ofcleaning solution 3 offered.( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size ofadditional reagent 1 offered.( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size of additional reagent 2 offered.( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here. , rate and pack size ofadditional reagent3 offered.( standard pack size and rate /pack available for the bidder may be filled up in the respective columns). rate will be freezed for 3 years. standard pack size which is used for calculation shall be mentioned here.
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results