BRR : 9544654
Tender Brief : Supply Of Hev Igm Elisa Test, Anti Hbc Total Elisa Test, Anti Hbc Igm Elisa Test, Anti Hcv Rapid Testhev Igm Elisa Test, Anti Hbc Total Elisa Test, Anti Hbc Igm Elisa Test, Anti Hcv Rapid Test,Srphc326049-Hev Igm Elisa Test: 1. Assay Should Be Based On The Principle Of Igm Ca Pture. 2. The Assay Should Detect Igm Anti Hev Antibodies. 3. Should Be Compatible With Plasma And Serum Both. 4. The Kit Size Should Be 96 Tests/Kit (In Strips Of 12X8 Wells Such That Individu Al Strips Can Be Used For Testing And The Same Are Compatible With Automated Elisa Reader An D Washer. 5. The Manufacturer /Auth... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 43,432.2
Submission Date
27-01-2026
Contract Date
12-02-2026
Completion Date
Ref. Document
Participated Bidder List
1 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 43,432.2 | L1 |
Work Detail
supply of hev igm elisa test, anti hbc total elisa test, anti hbc igm elisa test, anti hcv rapid testhev igm elisa test, anti hbc total elisa test, anti hbc igm elisa test, anti hcv rapid test,srphc326049-hev igm elisa test: 1. assay should be based on the principle of igm ca pture. 2. the assay should detect igm anti hev antibodies. 3. should be compatible with plasma and serum both. 4. the kit size should be 96 tests/kit (in strips of 12x8 wells such that individu al strips can be used for testing and the same are compatible with automated elisa reader an d washer. 5. the manufacturer /authorized agent should ensure maintenance of cold chain d uring storage and transport of kits at 2-8 degree c. 6. original technical data sheet should b e provided with each kit. 7. the assay component should include reactive and non-reactive co ntrols sufficient for atleast 4 runs. 8. the assay components should be sufficient for the 96 tests provided in four runs. 9. the assay should have sensitivity greater than and equal to 99 % and specificity greater than and equal to 98%. 10. the kit should have approval of the stat utory authority from the country of origin. 11. in case of imported kits it should be registere d and licensed by the dcg(i). 12. in case of indigenous manufactures should be licensed by the competent authority defined under drugs and cosmetics act at 1940 and also be evaluated by the centers approved by the government of india. 13. the kit should have minimum shelf life of 60% or 12 months(whichever is more) at the time of delivery to consignee. unit:test the item b e supplied with brand: mbs/labgene/elisa or similar ] , srphc326027-anti hbc total elisa test--96 tests/kit unit:test the item be supplied wi th brand: mbs/labgene/elisa or similar ] , srphc326030-anti hbc igm elisa test: 1. microplate elisa coated with igm monoclon al antibodies to hbc antigen. 2. assay should be based on the principle of igm capture. 3. shou ld be compatible with plasma and serum both. 4. the kit size should be 96 tests /kit (in strips of 12x8 wells such that individual strips can be used for testing and the same are compatible wi th automated elisa reader and washer. 5. the manufacturer /authorized agent should ensure maintenance of cold chain during storage and transport of kits at 2-8 degree c. 6. original te chnical data sheet should be provided with each kit. 7. the assay component should include r eactive and non-reactive controls sufficient for atleast 4 runs. 8. the assay components sho uld be sufficient for the 96 tests provided in four runs. 9. the assay should have sensitivity g reater than and equal to 98% and specificity of greater than and equal to 98%. 10. the kit sh ould have approval of the statutory authority from the country of origin. 11. in case of impo rted kits it should be registered and licensed by the dcg(i). 12. in case of indigenous manufact ures should be licensed by the competent authority defined under drugs and cosmetics act a t 1940 and also be evaluated by the centers approved by the government of india. 13. the kit s hould have minimum shelf life of 60% or 12 months(whichever is more) at the time of delivery to consignee. unit:test the item be supplied with brand: mbs/labgene/elisa or similar ] , srphc326047-anti hcv rapid test: 1. should be 3rd generation. 2. based on immunoc hromatography / immunofiltration for the qualitative detection of antibodies specific to hcv in human serum plasma or whole blood. 3. should be solid phase / particle coated with recomb inant and / or synthetic peptide antigens for core ns3 ns 4 and ns5. 4. should have in built qu ality control band or dot 5. should have short interpretation time not more than 30 minutes 6. should have specificity greater than and equal to 98% and sensitivity of greater than and equal to99% 7. must be evaluated and approved by nib 8. original technical data sheet should be provided with each kit. 9. the kit should have minimum shelf life of 60% or 12 months (which ever is more) at the time of delivery to consignee unit:test the item be supplied with brand: m bs/labgene/elisa or similar ] achd/surg.store/rh/per, sr tamil nadu 150.00 numbers acms/drug stores/rh/pgt, sr kerala 1056.00 numbers
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 6f798ad6-e384-4bb4-8f82-b20f652e59ee | result notice |
| Download | File Name | File Description |
|---|---|---|
| Download | f626631e-34cc-4a88-8c2c-e380ff53e9f3 | Tender Documents |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results