BRR : 9348963
Click Here To View Tendering Authority. Technical Bid City/State :  jammu, Jammu And Kashmir
Tender Brief : Tender For supply installation testing and commissioning Of Split Ac 02Tr Capacity 03 Nos Along With Electrical Other Allied Works To Be Installed In The Office Of Medical Record Officer Endocrinology Lab Of Gmch Jammu- 1 SITC of 2.0 TR split Air Conditionerswith all accessoriesand ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and having Air Flow Rate >=590 cfmwith minimum 3 star rating and of reputed makealong with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site re... Read More
Tender Value
2,74,800
Submission Date
26-07-2025
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
Work Detail
tender for supply installation testing and commissioning of split ac 02tr capacity 03 nos along with electrical other allied works to be installed in the office of medical record officer endocrinology lab of gmch jammu- 1 sitc of 2.0 tr split air conditionerswith all accessoriesand ambient upper temperature range of >= 52 degree celsius for cooling with maximum cooling capacity >= 6500 w and having air flow rate >=590 cfmwith minimum 3 star rating and of reputed makealong with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. complete job as per site requirement and instructions of engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. 2 sitcof wall mounted copper wound stabilizer for 02 tr air conditioners of capacity 5 kva (voltage range 90 volts-300 volts ) of reputed make i.e. electricfield/servocon/aulten/ microtek /v guard along with allied accessories. complete job as per site requirement and instructions of engineer-in-charge and also includes cost of materials, labourand all typesof taxes etc. 3 providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm isi marked, frls pvc insulated copper conductor cable and of standard make i.e. havells, polycab, finolex, anchor only for the purpose of connectingstablizersto the electrical panel . complete jobas per instructions of engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, tee-bends, thimbles etc.), labour charges, transportation charges 4 providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm isi marked, frls pvc insulated copper conductor cable of standard make i.e. havells, polycab, finolex, anchor only for the purpose of connectingair conditioning units (outer & inner) to the stablizer. complete jobas per instructions of engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and ta 5 providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with insulation. complete job must be as per instructions of engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, tee-bends, etc., labour charges, transportation charges and all other charges and taxes. 6 providing and laying of pvc drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the ac unit to a designated location, considering the specific requirements of the site. the pvc pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. job also includes miscellaneous workscivil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. complete jobas per instructions of engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, tee-bends,stands,spns etc.), labour charges, transportation charges and all other charges and tax
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download d5faec97-ad5b-4974-8b36-92499e98a65b technicalevaluation notice
Download techsummary_866518 aoc document
Download File Name File Description
Download be237fb8-d239-4f2f-8e06-c463238ed9c2 Tender Documents
Download BOQ_866518 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders