BRR : 9307822
Click Here To View Tendering Authority. Technical Bid City/State :  Pondicherry, Puducherry
Tender Brief : Rate Contract For Supply Of Consumables And Non Consumables Consumables/Non-Consumables For The Project Titled Rvrdl, Dept. Of Microbiology , Name Of The Item (Pack Size Wherever Mentioned Should Strictly Adherence The Other Pack Size Will Not Be Entertained) Rate To Be Quoted Only For The First Qualityterms And Conditions: Below Mentioned Kits Should Be Shipped To 12 Sites. , Malaria Antigen Detection (Rdt)•Based On Immunochromatography Using Monoclonal Antibody Specific For Antigenic Targets • Sample Type- Whole Blood • Test Kit Should Comprise Of Test Card/Strips/Cassettes And Reagents Inc... Read More
Tender Value
Ref. Document
Submission Date
12-08-2024
Participated Bidder List
9 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics
5 cnet-technologies Bid Analytics
6 cnet-technologies Bid Analytics
7 cnet-technologies Bid Analytics
8 cnet-technologies Bid Analytics
9 cnet-technologies Bid Analytics
Work Detail
rate contract for supply of consumables and non consumables consumables/non-consumables for the project titled rvrdl, dept. of microbiology , name of the item (pack size wherever mentioned should strictly adherence the other pack size will not be entertained) rate to be quoted only for the first qualityterms and conditions: below mentioned kits should be shipped to 12 sites. , malaria antigen detection (rdt)•based on immunochromatography using monoclonal antibody specific for antigenic targets • sample type- whole blood • test kit should comprise of test card/strips/cassettes and reagents including buffer solution in a dropper bottle. • should be who (world health organization) prequalified. necessary evidence to be submitted. • capable of detecting all 4 plasmodium species- p.falciparum, p.vivax, p.ovale and p.malariae. • ensure sensitivity and specificity at minimum 95 % at a parasite density level of 200 parasites/ microliter of blood. • shelf life should be minimum 2 years from date of supply • sample must be submitted at the time of tendering, failing which the bid shall not be considered , scrub typhus igm elisa • sample type-serum • product should be intended for in-vitro diagnostic use. • for detection of igm antibodies in human serum to orientia tsutsugamushi -derived recombinant antigen 56 kda. • the complete kit shall include 96 well strippable plate with all necessary reagents and controls. • product shelf life- 1 year or more • sample for the quoted kit must be submitted failing which bid will not be accepted , dengue ns1 elisa kit• sample type-serum • product should be intended for in-vitro diagnostic use. • the complete kit shall include 96 well strippable plate with all necessary reagents and controls. • the sensitivity and specificity of the kit should be 75-100% (field trial data) • product shelf life- 1 year or more • sample for the quoted kit must be submitted failing which bid will not be accepted. , leptospira igm elisa kit. • sample type-serum • product should be intended for in-vitro diagnostic use. • the complete kit shall include 96 well strippable plate containing leptospira antigen coated microwells with all necessary reagents and controls. • the sensitivity and specificity of the kit should be 95-100%. • product shelf life- 1 year or more • sample for the quoted kit must be submitted failing which bid will not be accepted , west nile igm elisa kit • sample type-serum • product should be intended for in-vitro diagnostic use. • for qualitative detection of igm antibodies to west nile recombinant antigens in human serum. • the complete kit shall include 96 well strippable plate containing west nile recombinant antigens coated micro wells with all necessary reagents and controls. • the sensitivity and specificity of the kit should be 95-100%. • product shelf life- 1 year or more • sample for the quoted kit must be submitted failing which bid will not be accepted , measles igm elisa • sample type-serum/csf • product should be intended for in-vitro diagnostic use. • for qualitative detection of igm antibodies to measles recombinant antigens in human serum and csf. • the complete kit shall include 96 well strippable plate containing measles antigen coated microwells with all necessary reagents and controls. • sensitivity should be 97 % and specificity 97% • product shelf life- 1 year or more. • sample for the quoted kit must be submitted failing which bid will not be accepted , denguepcr • the kit should be based on realtime taqman probe-based chemistry • the kit should be inclusive of all the chemical reagents mastermix, probes,positive & negative controls, internal controls • controls should be sufficient to do 10 – 15 batches of pcr • the pcr kit should be able to detect dengue virus - all genotypes (pan dengue primer) • the kits should be compatible on roche z 480/ lc480, thermofisher qs3, 5, 7500, biorad cfx100 platform etc. • should be ivd marked • analytical sensitivity should be minimum 10copies/ ul • kit should be supplied with column-based extraction kit , chikungunya pcr • the kit should be based on realtime taqman probe-based chemistry • the kit should be inclusive of all the chemical reagents mastermix, probes,positive & negative controls, internal controls • controls should be sufficient to do 10 – 15 batches of pcr • the pcr kit should be able to detect chikungunya virus • the kits should be compatible on roche z 480/ lc480, thermofisher qs3, 5, 7500, biorad cfx100 platform etc. • should be ivd marked • analytical sensitivity should be minimum 10copies/ ul • kit should be supplied with column based extraction kit , enterovirus pcr • the kit should be based on realtime taqman probe-based chemistry • the kit should be inclusive of all the chemical reagents mastermix, probes,positive & negative controls, internal controls • controls should be sufficient to do 10 – 15 batches of pcr • the pcr kit should be able to detect enterovirus virus - all genotypes • the kits should be compatible on roche z 480/ lc480, thermofisher qs3, 5, 7500, biorad cfx100 platform etc. • should be ivd marked • analytical sensitivity should be minimum 10copies/ ul • kit should be supplied with column based extraction kit.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download techsummary_858007 aoc document
Download 0710b3e1-69de-4ba0-b8c2-1ef89d86c49d technicalevaluation notice
Download File Name File Description
Download 85cc2dc9-0228-4d5a-a488-a01c9a8b8d28 Tender Documents
Download BOQ_858007 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders