BRR : 9288169
Click Here To View Tendering Authority. Technical Bid City/State :  neemuch, Madhya Pradesh
Tender Brief : Supply And Installation Of Fire Detection System , Conventional 2 Zone Fire Alarm Panel Without Battery Each Zone Capable Of Taking 20 Detectors, Power Supply 26.5Vdc,2.5,4 Monitored Siren/Relay Outputs (En54-2 Par.7.8 Certified , Repeater Expansion Port, (Connection To Optional Rs485 Expansion Module), Tcp/Ip Module For Connectivity To Smart View Software , Conventional Intrinsically Safe Optical Smoke Detectors Operating Voltage 14.8 V Dc To 28 V Dc, Operating And Storage Temperature : 40Deg.C To +70 Deg.C, Humidity (No Condensation Or Icing): 0% To 98% Rh, Housing: White Flame Retardant Po... Read More
Tender Value
Ref. Document
Submission Date
07-06-2024
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
Work Detail
supply and installation of fire detection system , conventional 2 zone fire alarm panel without battery each zone capable of taking 20 detectors, power supply 26.5vdc,2.5,4 monitored siren/relay outputs (en54-2 par.7.8 certified , repeater expansion port, (connection to optional rs485 expansion module), tcp/ip module for connectivity to smart view software , conventional intrinsically safe optical smoke detectors operating voltage 14.8 v dc to 28 v dc, operating and storage temperature : 40deg.c to +70 deg.c, humidity (no condensation or icing): 0% to 98% rh, housing: white flame retardant polycarbonate ,terminals: nickel plated stainless steel , conventional intrinsically safe sounder cum strobe, maximum sound output at one meter: 100db(a),supply voltage 6-28 vdc,ip 65 atexcertified, iecx certified , conventional flameproof manual call point is break -glass operated with a flap. it is approved for use in zone1,2,21 and 22hazardous areas, supply voltage 250v ac max ,50v dc max, operating temperature -40 deg.c to +55 deg.c ip66,atex certified, iecx certified, complies with en 54-11 , conventional galvanic barrier. voltage u0 28v current i0 93ma,power p0 0.65 w, explosion group iia iib iic,ip20, ambient temperature -20 deg c ….+60 deg.c _-4 of…140 of) , addressable zone monitor module, digital communication:xp95 (discovery and core protocol pulses of 5-9vdc., operating temperature -20 deg.c to +70deg.c,humidity (no condensation)0% to 95% rh ,ip54 , supplying, installation, testing and commissioning of ul listed addressable control relay modules , 12v 7 ah battery , 2c x1.5 sq.mm abc multistand pvc insulated twitted pair shielded armoured frls cable (red color) , flp double compression 1.m20 glands
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download technical_850041 aoc document
Download techsummary_850041 aoc document
Download 5cec5214-8b56-4ec0-acb1-9818135b7435 technicalevaluation notice
Download File Name File Description
Download NIT Tender Documents
Download Tendernotice_1 Tender Documents
Download fed43f41-5ee5-4168-a744-d085466a14a3 Tender Documents
Download BOQ_850041 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid