BRR : 9230740
Click Here To View Tendering Authority. Technical Bid City/State :  kollam, Kerala
Tender Brief : SUPPLY OF CONSUMABLES, REAGENTS AND OTHER ITEMS-Transfusion Medicine Supply Of Reagents, Consumables And Others For The Department Of Transfusion Medicine , Consumables, Reagents & Other Items , Lancet - Ready To Use Manual Blood Lancet; Sharp Point, All Sides Tapered Provides Quick, Clean Puncture Ribbed Surface For Firm Grip; Typical Incision Depth; Approximately 2Mm; Single Use; Sterile Individually Packed; Chrome-Polished Stainless Steel; Length, Approximately 40Mm,Width, Approximately 6Mm,Thickness, Approximately 0.5Mm , Tourniquet- Elastic Arm Tourniquet With Plastic Buckle; Should Hav... Read More
Tender Value
2,80,590
Submission Date
16-03-2023
Participated Bidder List
6 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics
5 cnet-technologies Bid Analytics
6 cnet-technologies Bid Analytics
Work Detail
supply of consumables, reagents and other items-transfusion medicine supply of reagents, consumables and others for the department of transfusion medicine , consumables, reagents & other items , lancet - ready to use manual blood lancet; sharp point, all sides tapered provides quick, clean puncture ribbed surface for firm grip; typical incision depth; approximately 2mm; single use; sterile individually packed; chrome-polished stainless steel; length, approximately 40mm,width, approximately 6mm,thickness, approximately 0.5mm , tourniquet- elastic arm tourniquet with plastic buckle; should have a stretchy strap that helps in easy adjustment; adjustable cuff size from 2 inch to 5 inch diameter; should be comfortable for the blood donor , spot plaster - should provide coverage and protection of phlebotomy site; should besterile andbreathable; square or round shaped. , exercise ball - soft rubber ball; 10 cm diameter; adequate grip , storage vial autoclavable sv 10 - 10ml vials plastic vials; should be autoclavable durable and long lasting , microtip yellow 2-200microlitre - microtip 2-200 microlitre compatible with multi channel pipette;even liquid dispensing and a good fit on the micropipette. autoclavable; hydrophobic, medical grade polypropylene, free of lubricants, dyes and heavy metals;tips with good seal on micro-pipettes; more transparency for clear visualization ; high clarity and finer tip orifice , vacuum tubes edta - vacuum polyproplene tubes with edta; transparent and see through 13x75 mm size. , vacuum tubes plain -vacuum polyproplene tubes; transparent and see through 13x75 mm size. , vacuum tubes with gel - vacuum polyproplene tubes with gel activator; transparentand see through; 13x75 mm size. , test tube rack sv 10 - should fit 10ml vials plastic autoclavable vials; durable and long lasting , test tube racks - should fit20 , 13* 75 mm test tubes; durable and long lasting. , filter paper kalpi - sheets should have 0.5 m width , available as rolls; should have good absorption , slides for microscopy - microscope glass slides 75 x 25 x 1.4 mm; scratch resisitant and clear; suitable for haema agglutination tests.-50/pkt , acdsolution a anticoagulant - 500 mlanticoagulant citrate dextrose solution(acd) solution a; should be sterile and pyrogen free solution in a polyolefin bag or bottle; should not contain antimicrobial and bacteriostatic reagents;the bag should be nontoxic and biologically inert; the bag-solution unit should beclosed system; the bag/ bottle should beoverwrapped to provide extra protection ; each 100 ml should contain: (%w/v) citric acid, monohydrate 0.8 g; dextrose monohydrate 2.45 g; sodium citrate dihydrate 2.2 g; and water for injection. , 3 cell panel screening cells - 3-cell screening for patients; should contains a set of 3 vials , 10 ml each for iat and nacl testing; should include two rhd positive cells (ccdee, cw+, ccdee) and one cell rhd negative (cc.ee) with configuration: r1wr1, r2r2, rr; should include double dose for fya, fyb, jka, jkb, m, s and s, and at least one cell positive for k, lea, leb, p1 and n; should betested by serology for hla class i antigens; should have a stability of 7 weeks ; should be supplied on standing order every 4 weeks; should be compatible with cat used in matrix centrifuge. , 11 cell panel cells - a set of 11 (4 ml) vials for iat and nacl testing; should have afixed rh phenotype pattern and assured presence of cells possessing double-dose antigens throughout representing the common asian /indian blood group antigens; should betested by serology for hla class i antigens; shouldhave a stability of 7 weeks; should be supplied on standing order every 4 weeks;should be compatible with cat used in matrix centrifuge. , anti h antisera - ready to use purified lectin extract of ulex europaeus seeds; optically clear ; titre: ~ 1:16 with o group cells; specificity: negative reacting with o phenotype h; reactivity:graded reactivity with different red cells,o>a >a b>b>a >a b ; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of1 year-5ml/pack , anti a1 antisera - ready to use purified lectin (phytohemagglutinin) extract of dolichos biflorus seeds; optically clear solution; should have titre of 1 ~ 1:16 with a1cells and1 ~ 1:16 with a1b cells; specificity of a1 antigen shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; sta-bility of2 year.-5ml/pack , anti d igg - should have atitreupto 512 dilution by two fold serial dilution in tubes; thereagent should bespecific for the purpose or not with rh negative cells as it should not sensitize rh negative cells; should eliminate prozone phenomenon with strongly sensitized cells in dat; should eliminate negative reaction with weakly sensitized cells in dat; stableat 2-8ºc with shelf life of 2 years; sodium azide is added to the antibodies at 0.1% concentration as preservative-10ml/pack , anti d (igg+ igm) - should contain anti-d (igm + igg) monoclonal antibodies; should agglutinate in saline solution;should be active at room temperature and 37°c; usable on glass slide as well as in the tube; should have a shelf life of 2 years at 2-8 degree c; should have an avidity of 5-10 sec; igm titre should be 1/256 and igg 1/8; 10ml/pack , pappain - stabilized ready to use papain reagent (liquid state); standardised as per aabb and fda guidelines; should have thiol reducing agent; stable for 2 years at 2-8degree c; can be used in cat compatible with matrix centrifuge-5ml/pack , bovine albumin (10ml)- 22% purified bovine serum albumin; ph 7.1 (± 0.2%) ; globulin free should give single band on gel electrophoresis; standardized as peraabb and fda guidelines; optimum concentration of stabilisers. stable at 2-8degree c for 2 years.-10ml/pack , anti c - ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dce/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dce/dce) phenotype;100%specificity to c antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines; 10ml vial , anti c - ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dce/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dce/dce) phenotype;100%specificity to c antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines.-2ml/pack , anti e - ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dce/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dce/dce) phenotype;100%specificity to e antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines--2ml/pack , anti e - ready to use reagents prepared from monoclonal cell culture supernatant of respective human cell lines;should be able to detect 1:32 with r’r (dce/dce) phenotype,1:32 with rr (dce/dce) phenotype,1:32 with r”r (dce/dce) phenotype;100%specificity to e antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines--2ml/packl , anti lewis a - 100% specificity to anti le a antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines--2ml/pack , anti duffy a - 100% specificity to duffy a antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines--2ml/pack , anti m - 100% specificity to m antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines--2ml/pack , monospecific gel cards - should havemicrotubes pre-filled with gel in a suitable buffer containing monospecific anti-igg antibodies; should rule out anti complement activity in ahg tests performed; card should be photocopiable ; shelf life of 1 year; standardised as per fda guidelines; should be compatible with matrix centrifuge. , elution kit for aiha - should identifyantibodies from sensitized red cells ; ready-to-use reagents for the acid elution of most common antibodies; should havestability;color change to indicate end of reaction phase . , forward &reverse abo grouping card - forward and reverse cat with grouping card with autocontrol; should contain monoclonal anti-a, anti-b and anti-d (igm) (vi-)a negative control andneutral gel used for reverse grouping; card should be photocopiable ; shelf life of 1 year; should be one profile/card; standardised as per aabb guidelines; should be compatible with matrix centrifuge.; 24/pack , rh kell grouping cards - forward and reverse cat with grouping card with autocontrol; should contain monoclonal anti-a, anti-b and anti-d (igm) (vi-)a negative control andneutral gel used for reverse grouping; card should be photocopiable ; shelf life of 1 year; should be one profile/card; standardised as per aabb guidelines; should be compatible with matrix centrifuge;24/pack , rh view box - should have soft fluorescent, glare-free light that provides excellent uniform slide illumination; 230 v,50 hz; temperature indicator required; compact and light weight; , haemoglobinometer - portable hand held analyser; light weight less than 250 gm for transportation to camp site ; interpretable results within 10 seconds; cuvettes should be reagent free; should have battery back up; should have an option for software installation for easy data transmission; should have two charging possibilities- usb and adaptor; should be robust for mobile use; should have minimal maintainenance and cleaning; should have option for barcode scans. , anti n-100% specificity ton antigen; shouldmaintain optimum ph ,ionic strngth, protein concentration and antibody activity; stability of2 year; standardised as per aabb and fda guidelines; 2ml/pack
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download technical_829897 aoc document
Download techsummary_829897 aoc document
Download c2a321c1-ca04-42cb-a581-d342613adb2d technicalevaluation notice
Download File Name File Description
Download etender-7781-2-2023-Tende Tender Documents
Download Tendernotice_1 Tender Documents
Download Tendernotice_2 Tender Documents
Download 8e0ec799-eb54-4d4e-a772-a39908fa7e65 Tender Documents
Download BOQ_829897 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders