BRR : 9039591
Click Here To View Tendering Authority. Technical Bid City/State :  167 Military Hospital, Dhangu Complex, Pathankot, Punjab
Tender Brief : Procurement Of Ortho Items , , Trauma Drape Pack For Upper Limb Consisting Of One Impervious U Drape, One Impervious O Drape, 4 X Large Sheets, Two Cling Films And Anaesthesia Isolation Sheet With Adhesive Strip. , Trauma Drape Pack Lower Limb Consisting Of One Impervious U Drape, One Impervious O Drape, 4 X Large Sheets, Two Cling Films And Anaesthesia Isolation Sheet With Adhesive Strip. , Triclosan Coated Braided Dyed Polyglactin For Orthopaedic Surgery Size No 2, 90 Cm Long Thread With Taper Cut Heavy Needle. Usfda Approved , Porous Hydroxyapatite With Tricalcium Phosphate ... Read More
Tender Value
Ref. Document
Submission Date
02-09-2021
Participated Bidder List
12 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics
5 cnet-technologies Bid Analytics
6 cnet-technologies Bid Analytics
7 cnet-technologies Bid Analytics
8 cnet-technologies Bid Analytics
9 cnet-technologies Bid Analytics
10 cnet-technologies Bid Analytics
11 cnet-technologies Bid Analytics
12 cnet-technologies Bid Analytics
Work Detail
procurement of ortho items , , trauma drape pack for upper limb consisting of one impervious u drape, one impervious o drape, 4 x large sheets, two cling films and anaesthesia isolation sheet with adhesive strip. , trauma drape pack lower limb consisting of one impervious u drape, one impervious o drape, 4 x large sheets, two cling films and anaesthesia isolation sheet with adhesive strip. , triclosan coated braided dyed polyglactin for orthopaedic surgery size no 2, 90 cm long thread with taper cut heavy needle. usfda approved , porous hydroxyapatite with tricalcium phosphate granules 30 ml , canulated cancellous 6.5 mm screw with spike washer for avlused ligament fixation. titanium. sterile packed. mri safe. , triclosan coated braided dyed polyglactin for orthopaedic surgery size no 1, 90 cm long thread with taper cut heavy needle. usfda approved , distal radius lcp t plate 3.5mm, complete construct with 3 locking and 3 cortical screws ( titanium ) , non stick, non charring disposable sterile cautery pencil with scratch pad , porous hydroxyapatite with tricalcium phosphate cylinder 10 mm long, 5 mm dia , clavicular anatomical plate 3.5 mm complete construct for left or right side with 6 cortical screws ( titanium ) , 4% chlorhexidine gluconate containing detergent with bathing sponge for preoperative bathing , arthroscopy beath needles , polybutylate coated braided polyester size 2, 1 / 2 circle taper cut, 45 mm single needle ( ethibond ) , sterile ( foil with single thread ) , braided dyed polyglactin orthopaedic suture size 2 , low viscosity pmma bone cement, antibiotic loaded, withpigment 40 gm. , finnish barrel burr shaver blades for arthroscopoic shaver system. implants should be usfda / ce ( european ) approved / certified, sterile packed disposable.should be compatible with karl storz shaver system. , titanium endobutton closed loop 20 mm, pre sterilised for acl or pcl reconstruction, with two differently colour coded loops for pulling and flipping , porous hydroxyapatite with tricalcium phosphate blocks 10 x 10 mm , sterile packed 5.5 mm titanium corkscrew anchorwith 2 x no. 2 uhmwpe braided suture ( different colour / pattern for each strand ) . implants should be mri safe and sterile packed , iodophor impregnated sterile adhesive incise drape 60x45cm, 15% variation in size acceptable , iodophor impregnated sterile adhesive incise drape 60x85cm, 15% variation in size acceptable , joint irrigation fluid 3 ltr , normal saline. , iodophor impregnated sterile adhesive incise drape 35x35cm, , 15% variation in size acceptable , braided dyed polyglactin orthopaedic suture size 1 , sterile disposable universal extremity drape with conforming circular fenestration & tube holders, 90” x 124” ( compliant with iso-11607-2, iso 11810-1standards ) 15% variation in size acceptable. , wide area fixation dressing roll- 10cm width. , cement gun syringe, sterile, disposable , ao pattern 4.0 mm partially threaded cannulated cancellous screws 20 to 80 mm length with washer titanium, should be mri safe. , ao pattern dcs barrel plate 95 degree, 10-14 dynamic compression holes with 60 to 85 mm lag screw , compression screw and 7 x self tapping 4.5mm cortical screws complete construct. material- 316lvm stainless steel.implant should be mri safe. , powder free gamma sterilized natural rubber latex, brown operating gloves with textured outer surface and polymer coated dermasheild technology inner surfece ( minimum thickness- 0.3 mm ) size 7.0 , powder free gamma sterilized natural rubber latex, brown operating gloves with textured outer surface and polymer coated dermasheild technology inner surfece ( minimum thickness- 0.3 mm ) size 7.5 , high viscosity bone cement pmma with pigment, antibiotic loaded 40 gm packet , medium viscosity bone cement pmma with pigment, antibiotic loaded 40 gm packet , post -operative transparent wound dressing with absorbent pad 10x8cms , wide area fixation dressing roll- 15cm width. , post -operative transparent wound dressing with absorbent pad 5x7cms , ilizarov wire bayonet tip, 3 faced chuck end, 1.8x370 mm.316lvm stainless steel. , single-use c-arm cover pair, bis protection level 1, with elastic at opening & double side adhesive & velcro fitting at opening of table side cover, size: 75cmx75cm, eo sterile. , vertical isolation drape for hip surgery of clear transparent waterproof material. ( compliant with aami pb70-2012 level 4 standards ) . adhesive incise area approximately 40cm x 75cm, fluid collection pouch with suction port, attachable instrument pouch, tube holders, central release tape strip for horizontal rod attachment . 10% variation acceptable. up to 10% variation in size acceptable. , port dressing. post operative sterile adhesive porouswith absorbent pad and confirmative fixative layer 5 cm x 5 cm , ultra high molecular weight polyethylene braided tape 1.5mm x 90 cm ( sterile, disposable ) . , ao pattern 4.0 mm solid cancellous screw, full threaded, length 14 mm to 70mm with washer, titanium, should be mri safe. , disposable plastic apron for arthroscopy surgery- sterile , disposable tie-on face mask ( 4 ply ) ( compliant with iso 22609 & en14683 standards ) , powder free gamma sterilized natural rubber latex, brown operating gloves with textured outer surface and polymer coated dermasheild technology inner surfece ( minimum thickness- 0.3 mm ) size 8.0 , circlage wire ( 18, 20, 22 gauge ) stainless steel , sterile packed transparent cling drape. , cement restrictor plug , glove examination nitrile powder free, box of 100 pieces, size medium , glove examination nitrile powder free, box of 100 pieces, size large , threaded guide wire 2.5 mm dia x 22 cm , sterile skin marking pen.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download technical_524865 aoc document
Download techsummary_524865 aoc document
Download 0d510bb5-1a3f-4ec5-8fbf-a73cd184d39f technicalevaluation notice
Download File Name File Description
Download 785a4d1d-af18-4b81-b72c-59985623c0a3 Tender Documents
Download BOQ_524865 Tender Documents
Download Tendernotice_1 Tender Documents
Download Tendernotice_2 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders