BRR : 8946826
Click Here To View Tendering Authority. Technical Bid City/State :  hazaribag, Jharkhand
Tender Brief : Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme , For 20 Hp Spv Ac Surface Pump , Solar Module Mounting ( Galvanised Steel ) Surfac... Read More
Tender Value
Ref. Document
Submission Date
03-03-2022
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
Work Detail
rate through e - quotations are invited for material category annexed as ( i ) 20 h.p. solar pump, vfd, solar panel set and ii ) 10 h.p. dc solar pump, solar panel, steel structure supplying, installation and commissioning for lift irrigation scheme rate through e - quotations are invited for material category annexed as ( i ) 20 h.p. solar pump, vfd, solar panel set and ii ) 10 h.p. dc solar pump, solar panel, steel structure supplying, installation and commissioning for lift irrigation scheme , for 20 hp spv ac surface pump , solar module mounting ( galvanised steel ) surface structure ( for 50 kw ) having hot deep galvanised ofzinc thickness 80micron and as per is4759 with c channel $ anti theft with nut bolt of grade ss304, which should also withstand high wind velocity upto 150km / hr or as per mnre. , 50kwp spv module of 330wp or higher rating, which must have specification as per is 14286 / iec 61215 .the module must have to quilifyis / iec 61730 part i $ ii ( or having mechanical load test of 5400pa ) for safety purpose.module to module wattage mismatch in spv array shall be + / -3% and to qualify iec ts 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per mnre. , spv controller / vfd integrated with gprs, having mppt , protection ip 65 or above as per mnre to run 20hp ac solar pump. , solar cable 4 mm2usedas per is 694 or as per mnre. , copper cable 95 mm2 used as per is 694 or as per mnre. , arrangement of lightening arrestor excluding earthing for 50kw & 3 nos. 20hp solar pump , 20 h.p. a.c. solar pump set ofhaving performance with respect to total head, maximum current, capacity, voltage range etc as per mnre guidelines. , array junction box ( ip 65 or above ) as per mnre for 50kw spv. , miscllaneous accessories for installation of 20h.p. solar pump , supplying, installation and commissioning charge of module and structure for 50kw. , maintenance for atleast 5 years or as per mnre guidelines for 50kw spv module & 3 nos. 20hp ac solar pump with all accessories , for 10 hp spv dc surface pump solar module mounting ( galvanised steel ) surface structure for 50 kw having hot deep galvanised ofzinc thickness 80micron and as per is4759 with c channel $ anti theft with nut bolt of grade ss304which should also withstand high wind velocity upto 150km / hr or as per mnre. , 50 kwp spv module 330wp or higher which must have specification as per is 14286 / iec 61215 .the module must have to quilifyis / iec 61730 part i $ ii ( or having mechanical load test of 5400pa ) for safety purpose.module to module wattage mismatch in spv array shall be + / -3% and to qualify iec ts 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per mnre. , spv controller / vfd integrated with gprs, having mppt , protection ip 65 or above as per mnre to run 10hp dc solar pump. , solar cable of 4mm2 used as per is 694 or as per mnre , copper cable 25mm2 used as per is 694 or as per mnre. , arrangement of lightening arrestor excluding earthingas per mnre for 50kw spv $ 5 nos 10hp dc solar pump. , 10 h.p. d.c. ( pmsm / bldc / srm ) solar pump set ofhaving performance with respect to total head, maximum current, capacity, voltage range etc as per mnre guidelines. , array junction box ( ip 65 or above ) as per mnre for 50 kw spv. , miscllaneous accessories for installation of 10 h.p. solar pump , supplying, installation and commissioning charge of module and structure for 50kw. , maintenance for atleast 5 years or as per mnre guidelines for 50kw spv module & 5 nos. 10hp dc solar pumpwith all accessories
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download technical_76189 aoc document
Download techsummary_76189 aoc document
Download 7a61b996-95fc-4f0c-9313-9315f0fc89ef technicalevaluation notice
Download File Name File Description
Download 264c1390-1a8f-43ce-900d-531410c0a05c Tender Documents
Download BOQ_76189 Tender Documents
Download CONDITION_EOI_04_02 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders