BRR : 8910241
Click Here To View Tendering Authority. Technical Bid City/State :  NEIGRIHMS, Shillong, Meghalaya, Meghalaya
Tender Brief : Description Of Stores / Items: Processing Of Intra Ocular Lenses ( Iols ) , On Case To Case Consignment Basis, On Rate Contract For A Period Of 3 Years Or Till The Finalization Of The Next Tender, Whichever Is Later. For Department Of Ophthalmology - 1 Foldable Posterior Chamber Intraocular Lens ( Lens Power ) :- Nmaterial: Acrylic, Hydrophobic, Posterior Truncated Square Edge, Uv And Blue Light Filtering, Anterior Biconvex, Planar Haptics, Optic Type - Aspheric, Optic Diameter - 6Mm, Overall Length Approx. 13.0 Mm, Yellow Chromophore Is A Must, Refractive Index - Approx... Read More
Tender Value
Ref. Document
Submission Date
05-08-2021
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
Work Detail
description of stores / items: processing of intra ocular lenses ( iols ) , on case to case consignment basis, on rate contract for a period of 3 years or till the finalization of the next tender, whichever is later. for department of ophthalmology - 1 foldable posterior chamber intraocular lens ( lens power ) :- nmaterial: acrylic, hydrophobic, posterior truncated square edge, uv and blue light filtering, anterior biconvex, planar haptics, optic type - aspheric, optic diameter - 6mm, overall length approx. 13.0 mm, yellow chromophore is a must, refractive index - approx. 1.55, optic thickness should be approx. <0.8mm. smooth on injecting the iol into the capsular bag. no air bubble in the cartridge. should unfold easily within 10 secs. n 2 a ) +17.0 d 3 b ) +17.5 d 4 c ) +18.0 d 5 d ) +18.5 d 6 e ) +19.0 d 7 f ) +19.5 d 8 g ) +20.0 d 9 h ) +20.5 d 10 i ) +21.0 d 11 j ) + 21.5 d 12 k ) +22.0 d 13 l ) +22.5 d 14 m ) +23.0 d 15 n ) +23.5 d 16 o ) +24.0 d 17 p ) +24.5 d 18 q ) +25.0 d 19 r ) +25.5 d 20 s ) +26.0 d 21 foldable pre-loaded iol with delivery system ( iol powers ) :- nmaterial: acrylic, hydrophobic, posterior truncated square edge & anterior biconvex, planar haptics, optic type – aspheric, optic diameter - 6mm, overall length approx. 13.0 mm, light filtration - uv, blue light filtering & yellow chromophore is a must, smooth on injecting the iol into the capsular bag. should unfold easily within 10 seconds. refractive index approx 1.55, optic thickness <0.8mm, microincision 2.2mm disposable injector. delivery system / injector must be provided. from reputed company n 22 +20.0 d 23 +20.5 d 24 +21.0 d 25 +21.5 d 26 +22.0 d 27 +22.5 d 28 +23.0 d 29 +23.5 d 30 +17d 31 +18d 32 +19d 33 +24d 34 +25d 35 toric foldable posterior intraocular lens ( lens power ) :- nmaterial: foldable toric iols, acrylate / methacrylate copolymer, hydrophobic, posterior square-edge, biconvex, optic-aspheric, optic diameter - 6mm, uv-blocking, blue light & yellow chromophore is a must. ant. surface aspheric, single-piece iol with diffracrive, should also provide: ( i ) fixation ring with degree gauge / marker for accurate axis alignment, ( ii ) axis marker ( intraoperative ) to mark axis on cornea to be provided, iol cylinder powers ( diopters ) +1.50d to 6.00d, smooth on injecting the iol into the capsular bag. no air bubble in the cartridge. should unfold easily within 10 secs. n 36 +19.0d 37 +19.5d 38 +20.0d 39 +21.5d 40 +22.0d 41 +22.5d 42 +23.0d 43 +23.5d 44 trifocal iols: ( 1 ) high end quality :- nfoldable hydrophobic ( >90% ) acrylic iols, 3 focal points, optic of lens should have truncated square edge. refractive-diffractive optic, wide range of diopter 6d to 30d. microincision 2.2mm disposable catridge / preloaded injector. truncated square edge, optic diameter - 6mm, diopter approx - 12.5d, c-loops haptics, refractive index: approx 1.55. good defocus aspheric surface curve, negligible or no glare, halos or scattering of light, should provide good contrast sensitivity, should provide clear, far, intermediate - near vision, slanted transition zones, reduced pupillary dependence, balanced distribution of light, able to tolerate some decentration, near add: approx. +2.0 intermediate: approx 3.50d, uv, blue light filter & yellow chromophore is a must. smooth injection of iol. should unfold easily within 10 seconds. n 45 +19.0d 46 +19.5d 47 +20.0d 48 +20.5d 49 +21.5d 50 +22.0d 51 +22.5d 52 +23.0d 53 +23.5d 54 trifocal iols: ( 2 ) under make in india initiative:- nfoldable hydrophobic ( >90% ) acrylic iols, 3 focal points, optic of lens should have truncated square edge. refractive-diffractive optic, wide range of diopter 6d to 30d. microincision 2.2mm disposable catridge / preloaded injector. truncated square edge, optic diameter - 6mm, diopter approx - 12.5d, c-loops haptics, refractive index: approx 1.55. good defocus aspheric surface curve, negligible or no glare, halos or scattering of light, should provide good contrast sensitivity, should provide clear, far, intermediate - near vision, slanted transition zones, reduced pupillary dependence, balanced distribution of light, able to tolerate some decentration, near add: approx. +2.0 intermediate: approx 3.50d, uv, blue light filter & yellow chromophore is a must. smooth injection of iol. should unfold easily within 10 seconds. from indian company under make in india initiative. n 55 +19.0d 56 +19.5d 57 +20.0d 58 +20.5d 59 +21.5d 60 +22.0d 61 +22.5d 62 +23.0d 63 +23.5d 64 scleral fixated iol: na ) rigid, pmma iol, optic diameter - 6mm, eyelets for tying sutures, scleral fixated type, uv, blue light filter &yellow chromophore is a must. n 65 +18.0d 66 + 19.0d 67 + 20.0d 68 + 20.5d 69 + 21.5d 70 + 22.0d 71 scleral fixated iol ( foldable ) :- n ( b ) foldable iol with haptic material for making a flange with cautery for yamane technique, optic diameter - 6mm, uv, blue light filter & yellow chromophore is a must. n 72 +18.0 d 73 + 19.0d 74 + 20.0d 75 + 20.5d 76 + 21.5d 77 + 22.0d 78 phakic iol / intra cameral lens ( icl ) :- nintracameral phakic iol, collamer / hybrid acrylic material, power range: +15d to -30d, in 0.5d steps, optic type : aspheric vault height : approx 1-1.8mm, overall length approx. 11-14 mm ( in 0.25mm steps ) adequate number of holes for aqeous flow, adequate number of haptic pads to ensure better stability, refractive indx: approx. 7.465. delivery system should be provided. 79 scleral fixated iol:- rigid, pmma iol, optic diameter - 6mm, eyelets for tying sutures, scleral fixated type 80 +18.0 d 81 + 19.0d 82 + 20.0d 83 + 20.5d 84 + 21.5d 85 + 22.0d 86 phakic iol / intra cameral lens ( icl ) :- intracameral phakic iol, collamer / hybrid acrylic material, power range: +15d to -30d, adequate number of holes for aqeous flow, adequate number of haptic pads to ensure better stability, delivery system should be provided 87 injections: 88 inj. ranibizumab for intra vitreal inj. 0.05ml ( 10mg / ml ) - inj. ranibizumab 10 mg / ml. for intraocular use only 89 inj. dexamethasone implant ( ozurdex ) 0.7mg - intravitreal implant, .07 mg dexamethasone. pre-loaded single use.for intraocular useonly 90 inj. 20% sodium fluosrscein eye - inj. 20% sodium fluosrscein eye. for fundus fluorescein angiography 91 inj. trypan blue - trypan blue - 0.6 mg, sodium chloride i.p - 8.2 mg, sterile aqueous base - q.s, for intraocular use only 92 inj.hyaluronidase 1500 ( hyalase / facidase ) - each vials contains hyaluronidase ( ovine ) ip 1500 iu, excipients q.s, . for intraocular use only 93 inj. ( hydroxypropyl methyl cellulose ophthalmic. soln. 2% ) ( intraocular use ) - sterile, isotonic, apyrogenic viscoelastic sollution, hydroxy propyl methyl cellulose ( hpmc ) solution, high molecular weight. viscosity - 4500 to 5500 cps and the ph is 6.8 to 7.4. for intraocular use only. 94 b-hex pupillary expander with injector - soft foldable material for expansion of non dilating pupil, should be able to go in of ? 3 mm incision size 95 ophthalmic viscoelastic devices:- n hyopt plus injection:- each 0.5ml sodium hyaluronate ophthalmic slution contains: na hyaluronate bp 11.9mg +, na chloride usp 7.20 mg+, di-sodium hydrogen phosphate de-hydrate usp 0.238mg+, na di-hydrogenphosphate ponohydrate usp 0.034mg+, water for injection usp q.s. n 96 iris hook - flexible iris retractors, disposable. prolene material 97 artificial eye ball implant 98 hydro apatite -adult 99 hydro apatite -paediatric 100 hydro apatite -infant 101 eye shield confromer -infant 102 eye shield confromer -adult 103 i -care rebound tonometer disposable probes -disposable probes compatible for i-care rebound tonometer
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download technical_670990 aoc document
Download techsummary_670990 aoc document
Download 9f6c748c-1ceb-49d2-b901-c8814c3cbe12 technicalevaluation notice
Download File Name File Description
Download Tendernotice_1 Tender Documents - Processing of Intraocular Lens /Implants /Consumables on consignments basis
Download 2DC61029-894D-4435-9F5E-4CF844194F39 Tender Documents - Tender Notice
Download BOQ_670990 Tender Documents - Processing of Intraocular Lens /Implants /Consumables on consignments basis
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders