BRR : 8873801
Tender Brief : Supply And Installation Of Lab Equipment Two Rota Vapour For Ceps Supply And Installation Of Lab Equipment Two Rota Vapour For Ceps . , Laying And Jointing Pvc Pipe. Heading , Specifications Of Rota Vapour Are As Follows: • End Stop Position: The Push Button Height Adjustment ( Electronic Lift ) • Immersion Angel Adjustment With 6 Or More Angles • Automatic Operation Sops On Power Failure ( Lifts Flask Automatically Out Of Heating Bath ) • Rotation Speed 10 – Up To 280 Rpm Or Higher • Maximum Flask Load Up To 3Kg Or Higher • Foam Sensor And Level Sensor Are Optional • Vertical Condenser... Read More
Tender Value
₹
15,00,000
Submission Date
21-12-2021
Participated Bidder List
1 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics |
Work Detail
supply and installation of lab equipment two rota vapour for ceps supply and installation of lab equipment two rota vapour for ceps . , laying and jointing pvc pipe. heading , specifications of rota vapour are as follows: • end stop position: the push button height adjustment ( electronic lift ) • immersion angel adjustment with 6 or more angles • automatic operation sops on power failure ( lifts flask automatically out of heating bath ) • rotation speed 10 – up to 280 rpm or higher • maximum flask load up to 3kg or higher • foam sensor and level sensor are optional • vertical condenser bath should allow the use of water and oil as a heating media up to 200 c. mechanical and electronic over-temperature control ( cuts off power when actual temperature exceeds set temperature and also set point ) display should be digital, displays all operating parameters ( indicates set and actual values of heating bath temperature, rotation speed and lift position ) pump: the vacuum pump should be chemically resistant ptfe diaphragm pumps with low noise emission. the suction capacity should be 1.8m3 / h or higher re-circulating chiller: temperature range – 10 c to 25 c with flow rate 2.5l / min. or higher. with digital display ( resolution 0.1 c )
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results