BRR : 8722117
Click Here To View Tendering Authority. Technical Bid City/State :  IIM Indore, Madhya Pradesh
Tender Brief : Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . Yearly Testing Of Ht / Lt Equipments As Per Mpeb Inspection Report -Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . , Vacuum Circuit Breakers:- Service Charges For Carrying Out Servicing And Overhauling Of 1250 Ampere , Indoor Type 33 Kv , 3 Phase , 50 Hz , Make - Alstom , Type - Vmx , Vcb By Drawing Out The Draw-Out Module Of The Breaker , Carrying Out Complete Cleaning With Clean Cloth & Cleaning Agent , Lubrication Of The Mechanism & Greasi... Read More
Tender Value
8,59,369
Submission Date
16-12-2019
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
Work Detail
annual preventive maintenance of ht and lt electrical installation work at iim indore . yearly testing of ht / lt equipments as per mpeb inspection report -annual preventive maintenance of ht and lt electrical installation work at iim indore . , vacuum circuit breakers:- service charges for carrying out servicing and overhauling of 1250 ampere , indoor type 33 kv , 3 phase , 50 hz , make - alstom , type - vmx , vcb by drawing out the draw-out module of the breaker , carrying out complete cleaning with clean cloth & cleaning agent , lubrication of the mechanism & greasing with high temperature molly grease , testing for smoother on / off operation , carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relay , checking of healthiness of cts & pts chacking of ir value of interrupters , heaithiness of protection tripping of circuit breaker etc . checking and service switchgear interlocks and safety like ( mechanical: - 1 . positive interlock , 2 . negative interlock , 3 . spring discharge interlock , 4 . padlocks , 5 . key interlocking , 6 . safety roll in stop , 7 . safety roll-out stop , 8 . rating interference interlock ) . ( electrical:- interlock switches ) checking of electrical operations of the breaker for on / off & trip operation for incomer and outgoing including submission of service & test reports . the service to be done by authorised service provider of alstom . the rate shall include the material , labour , transportation , tools and tackles etc complete as required . , vacuum circuit breakers:- service charges for carrying out servicing and overhauling of 630 ampere , indoor type 11 kv , 3 phase , 50 hz , make - alstom , type - vmx , vcb by drawing out the draw-out module of the breaker , carrying out complete cleaning with clean cloth & cleaning agent , lubrication of the mechanism & greasing with high temperature molly grease , testing for smoother on / off operation , carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relay , checking of healthiness of cts & pts chacking of ir value of interrupters , heaithiness of protection tripping of circuit breaker etc . checking and service switchgear interlocks and safety like ( mechanical: - 1 . positive interlock , 2 . negative interlock , 3 . spring discharge interlock , 4 . padlocks , 5 . key interlocking , 6 . safety roll in stop , 7 . safety roll-out stop , 8 . rating interference interlock ) . ( electrical:- interlock switches ) checking of electrical operations of the breaker for on / off & trip operation for incomer and outgoing including submission of service & test reports . the service to be done by authorised service provider of alstom . the rate shall include the material , labour , transportation , tools and tackles etc complete as required . , vacuum circuit breakers:- service charges for carrying out servicing and overhauling of 630 ampere , indoor type 11 kv , 3 phase , 50 hz , make - crompton greaves , type - vmx , vcb by drawing out the draw-out module of the breaker , carrying out complete cleaning with clean cloth & cleaning agent , lubrication of the mechanism & greasing with high temperature molly grease , testing for smoother on / off operation , carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relay , checking of healthiness of cts & pts chacking of ir value of interrupters , heaithiness of protection tripping of circuit breaker etc . checking and service switchgear interlocks and safety like ( mechanical: - 1 . positive interlock , 2 . negative interlock , 3 . spring discharge interlock , 4 . padlocks , 5 . key interlocking , 6 . safety roll in stop , 7 . safety roll-out stop , 8 . rating interference interlock ) . ( electrical:- interlock switches ) checking of electrical operations of the breaker for on / off & trip operation for incomer and outgoing including submission of service & test reports . the service to be done by authorised service provider of alstom . the rate shall include the material , labour , transportation , tools and tackles etc complete as required . , vacuum circuit breakers:- service charges for carrying out servicing and overhauling of 630 ampere , indoor type 11 kv , 3 phase , 50 hz , make - abb , type - vmx , vcb by drawing out the draw-out module of the breaker , carrying out complete cleaning with clean cloth & cleaning agent , lubrication of the mechanism & greasing with high temperature molly grease , testing for smoother on / off operation , carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relay , checking of healthiness of cts & pts chacking of ir value of interrupters , heaithiness of protection tripping of circuit breaker etc . checking and service switchgear interlocks and safety like ( mechanical: - 1 . positive interlock , 2 . negative interlock , 3 . spring discharge interlock , 4 . padlocks , 5 . key interlocking , 6 . safety roll in stop , 7 . safety roll-out stop , 8 . rating interference interlock ) . ( electrical:- interlock switches ) checking of electrical operations of the breaker for on / off & trip operation for incomer and outgoing including submission of service & test reports . the service to be done by authorised service provider of alstom . the rate shall include the material , labour , transportation , tools and tackles etc complete as required . , air circuit breaker: complete service , overhauling , repairing , cleaning , oiling with setting of tripping mechanism of following air circuit breaker ( acbs ) including submission of service & test reports . the serviceing to be done by authorised service provider of ge and l&t . , 3200 amp mdo / edo 4p acb of ge make , 2500 amp mdo / edo 4p acb of ge make , 1000 amp mdo / edo 4p acb of ge make , 1600 amp mdo / edo 4p acb of l&t make model c- power , 1000 amp mdo / edo 4p acb of l&t make model c- power , 1600 amp edo 4p acb of l&t make model u- power , 2000 amp edo 4p acb of l&t make model u- power , 1000 amp edo 4p acb of l&t make model u- power , 800 amp edo 4p acb of l&t make model u- power , 1000 amp edo 3p acb of ge make model m-pact type . , calibration and setting of the static / electromechnical relay over voltage relay - 01 no , under voltage relay - 01 no . over current - 02 nos & earth fault relay - 01 nos . master trip relay ( b / a , wt / a , ot / a ) & ( b / t , wt / t , ot / t ) test by secondary injection test . the report will be prepared and to be submit . calibration and setting of the relay need to be carryout as per actual loading condition . also submit the calculation sheet for relay setting . , calibration and setting of the relay over current 02 nos . & earth fault relay 01 . nos . , master trip relay ( b / a , wt / a , ot / a ) & ( b / t , wt / t , ot / t ) test by secondary injection test . the report will be prepared and to be submit . calibration and setting of the relay need to be carryout as per actual loading condition . also submit the calculation sheet for relay setting . , calibration and setting of the relay over current 02 nos . & earth fault relay 01 . nos . , test by secondary injection test . the report will be prepared and to be submit . calibration and setting of the relay need to be carryout as per actual loading condition . also submit the calculation sheet for relay setting . , annual maintenance of transformers & switchyard . complete serviceing of oil- filter transformerof following rating , including replacement of gaskets to prevent oil leakage as per reqirement , replacement of silica gel ,
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download technical_548676 aoc document
Download techsummary_548676 aoc document
Download be2ac6d5-69dd-4094-9caf-aaa4cc472cac technicalevaluation notice
Download File Name File Description
Download BOQ_548676 Tender Documents - Financial Bid Document
Download 16F019BF-5413-4A94-B3FD-81E7B15DF9DF Tender Documents - Tender Notice
Download Tendernotice_1 Tender Documents - Technical Bid Document
Download 8657670_0_04122019 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders