BRR : 8718364
Tender Brief : Supply Installation Testing Commissioning And Major Repair Replacement Of Air Conditioner :-Sitc Of Water Cooled Chiller Of 37 . 5Tr ( R-407 ) ( Voltas Make ) , Sitc Of Water Cooled Chiller Of 60Tr ( R-407 ) ( Voltas Make ) , Insulated Chilled Water Piping ( Make- Jindal ) Sitc Of Chilled Water ( Gi ) Piping With Nitrile Insulation Standard Make ( A ) 80Mm Dia ( 32Mm Insulation ) , ( B ) 100Mm Dia ( 32Mm Insulation ) , Providing And Fixing In Position The Industrial Type Pressure Gauge Complete Standard Make , Providing & Fixing In Position The Mer... Read More
Tender Value
₹
Ref. Document
Submission Date
15-11-2019
Participated Bidder List
2 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics |
Work Detail
supply installation testing commissioning and major repair replacement of air conditioner :-sitc of water cooled chiller of 37 . 5tr ( r-407 ) ( voltas make ) , sitc of water cooled chiller of 60tr ( r-407 ) ( voltas make ) , insulated chilled water piping ( make- jindal ) sitc of chilled water ( gi ) piping with nitrile insulation standard make ( a ) 80mm dia ( 32mm insulation ) , ( b ) 100mm dia ( 32mm insulation ) , providing and fixing in position the industrial type pressure gauge complete standard make , providing & fixing in position the mercury in glass industrial type thermometer complete standard make , auto air vent - 15mm dia standard make , insulated valves ( make - advance ) butterfly valve / ball valve ( manual ) with c i body ss disc , nitrile rubber seal & o- ring pn 16 pressure rating for chilled water / hot water circulation as specified ( a ) 100 mm dia ( butterfly valve ) , ( b ) 80 mm dia ( butterfly valve ) , balancing valve with built in measuring facility with c i body flanged ( make - advance ) ( a ) 100 mm dia , ( b ) 80 mm dia , condenser water piping ( make- jindal ) supplying , fixing , testing and commissioning of condenser water pipes of following sizes of gi c class along with necessary clamps , vibration isolators and fittings such as bends , tees , etc . ( a ) 100 mm dia , ( b ) 125 mm dia , non insulated valves butterfly valve ( manual ) with ci body ss discs nitrile sheet & o-ring & pn 16 pressure rating as specified . ( make - advance ) ( a ) 125 mm dia , ( b ) 100 mm dia , ( c ) 40 mm dia -ball valve , ( d ) 32 mm dia -ball valve , balancing valve ( make - advance ) ( a ) 100 mm dia , ( b ) 125 mm dia , y - strainer of ductile ci body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified . ( make- emerald ) ( a ) 100 mm dia , ( b ) 125 mm dia , providing and fixing in position the industrial type pressure gauge complete as required , providing & fixing in position the mercury in glass industrial type thermometer complete as required , electrical work , cable termination work , civil work related to plant work , sitc of ahu of 30 , 000 cfm with pre & fine filter;18kw heating strips sp=65 , cooling coil- 6rd with humidifier ( make- zeco / edgetech ) coil tray shall be made of ss304 , sitc of ahu of 20 , 000 cfm with pre & fine filter; 18kw heating strips sp=65 , cooling coil- 6rd with humidifier ( make- zeco / edgetech ) coil tray shall be made of ss304 , insulated chilled water piping ( make- advance ) sitc of chilled water ( gi ) piping with nitrile insulation ( a ) 80mm dia ( 32mm insulation ) gi , ( b ) 100mm dia ( 32mm insulation ) gi , providing and fixing in position the industrial type pressure gauge complete standard make , providing & fixing in position the mercury in glass industrial type thermometer complete standard make , insulated valves butterfly valve / ball valve ( manual ) with c i body ss disc , nitrile rubber seal & o- ring pn 16 pressure rating for chilled water / hot water circulation as specified ( make- advance ) ( a ) 100 mm dia ( butterfly valve ) , ( b ) 80 mm dia ( butterfly valve ) , balancing valve with built in measuring facility with c i body flanged ( make- advance ) ( a ) 100 mm dia , ( b ) 80 mm dia , 3 way valve with actuator ( a ) sitc of 80 mm dia , ( b ) sitc of 65 mm dia , electrical work , cable termination work , panel for humidity controller and cabling work , planum connection , canvas connection of ahus , civil work / foundation work related to ahus , replacement of damaged corroded duct with nitrile insulation , supply and installation of eu-13 box type , size: 610x610x305mm , efficiency: 99 . 97% , down to 0 . 3 micron , standard make , dismantling of existing ct motor , supply , installation , testing and commissioning of cooling tower motor and its terminal connections
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | Tendernotice_1 | Tender Documents - SUPPLY INSTALLATION TESTING COMMISSIONING AND MAJOR REPAIR REPLACMENT OF AIR CONDITIONER |
| Download | 67C991A4-0E95-4DE1-ADAB-11964BCE4C98 | Tender Documents - Tender Notice |
| Download | BOQ_37734 | Tender Documents - PRICE BID AS PER BOQ |
| Download | TN_07565_0268 | Tender Documents - AND MAJOR REPAIR REPLACMENT OF AIR CONDITIONER |
| Download | 8289933_21456_08112019 | Tender Documents |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid