BRR : 8594695
Click Here To View Tendering Authority. Aoc City/State :  24 Paraganas North, West Bengal
Tender Brief : Repairing of MCC with ATSPanel at BS-III in AA-IIIC under NTK Project.-- 1 Supply & delivery at site of following spares :-Over Current Earth Fault Relay [Make : ALSTOM, Model : P154AGILE] 2 Auxiliary Relay [Make : GE T&D , Model : VAA33ZG8338BCH, Aux. supply : 110-125V DC] 3 Deputing of skilled Technicians and personnel to inspect the ATS in 200kW of Pump no. - 2 spare at site dismantling, Megar Report, Tests conducted as per direction of the EIC. 4 Carrying of the ATS Worksiteto Kolkata workshop and back to site after repairing including loading and unloading charges. 5 Repairing of th... Read More
Tender Value
2,20,701
Contract Value
₹ 2,20,149
Saving / Difference
₹ 552 ▲
Submission Date
23-08-2025
Contract Date
28-08-2025
Completion Date
30 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 2,22,908.11 L2
2 cnet-technologies Bid Analytics 2,25,666.88 L3
3 cnet-technologies Bid Analytics 2,20,149 L1
Work Detail
repairing of mcc with atspanel at bs-iii in aa-iiic under ntk project.-- 1 supply & delivery at site of following spares :-over current earth fault relay [make : alstom, model : p154agile] 2 auxiliary relay [make : ge t&d , model : vaa33zg8338bch, aux. supply : 110-125v dc] 3 deputing of skilled technicians and personnel to inspect the ats in 200kw of pump no. - 2 spare at site dismantling, megar report, tests conducted as per direction of the eic. 4 carrying of the ats worksiteto kolkata workshop and back to site after repairing including loading and unloading charges. 5 repairing of the spare ats 200kw of pump no. -2 at works includes opening the coils from ats and dismantling the same, supply and fixing of new copper with double nomax, insullation, supply of varnish (elmo-50), supply & fixing of nomaxinterlayer, reassembling of the coil after winding & fixing the top core along with necessary connection and testing of the transformer complete. (rate is calculated after deducting the value of scrap copper) 6 fitting fixing of the ats starter inter connection, socketing, control wiring checking, circuit checking, with over current earth fault replacement & calibration and auxiliary relay replacement & calibration testing commisioning to the entire satisfaction of the eic.n.b.:if any defect arises within one year, agency should repair / replace free of cost.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 0198351b-e2a1-459e-b48e-efb9da69aa44
Download boqcomparativechart
Download finsummary_2001979
Download techsummary_2001979
Download WO
Download File Name File Description
Download c70ac654-7577-4ad6-a4f7-7569ab27b484 Tender Documents
Download BOQ_2001979 Tender Documents
Download Tendernotice_1 Tender Documents
Download Tendernotice_2 Tender Documents
Download Tendernotice_3 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results