BRR : 8438690
Click Here To View Tendering Authority. Aoc City/State :  sealdah, West Bengal
Tender Brief : Supply Of Triple Lumen Hemodailysis Catheter (Curved), Specification For Triple Lumen Haemodialysis Catheter, Size: 12.5 F Material: Thermosensitive Polyurethane Material No Of Lumen: 3 (Three). Third Lumen Must Be Usable For Drug Delivery, Cvp Monitoring, Transfusions. Third Lumen Must Be Of 19G Diameter. All The Lumens Must Be Marked With Priming Flow Rate Preferrable Laser Etched. Common Hub Must Be Reinforced To Reduce Kinking Of Lumens. Catheter Shaft Must Be Marked With Depth Markings For Ease Of Insertion. Lumen Must Be Of Modified Double-D Design For Consistence Flow Even During Low A... Read More
Tender Value
Ref. Document
Contract Value
₹ 2,91,375
Submission Date
17-09-2025
Contract Date
16-12-2025
Completion Date
Ref. Document
Participated Bidder List
1 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 2,91,375 L1
Work Detail
supply of triple lumen hemodailysis catheter (curved), specification for triple lumen haemodialysis catheter, size: 12.5 f material: thermosensitive polyurethane material no of lumen: 3 (three). third lumen must be usable for drug delivery, cvp monitoring, transfusions. third lumen must be of 19g diameter. all the lumens must be marked with priming flow rate preferrable laser etched. common hub must be reinforced to reduce kinking of lumens. catheter shaft must be marked with depth markings for ease of insertion. lumen must be of modified double-d design for consistence flow even during low arterial pressure. main shaft must have laser cut side slot. tip must be symmetrically designed. guidewire: j tipped nitinol core kink free guide wire with thumb advancer needle: 18g introducer needle/18 g safety introducer needle. dilator: 2 in number, 10 f and 12 f. package: sterile pack must contain the followings: beside catheter, needle, dilators, guidewire 5/6 ml luer lock syringe. retractable safety scalpel fenestrated drape large 2.0/1.0 nylon suture with cutting needle. antiseptic applicator wand. island dressing 2 in number/ or transparent wound dressing 6-8 sterile gauze sponges 3 sealing caps. desirable inclusion in the pack: a pair of gloves, dressing gown.triple lumen hemodailysis catheter (curved), specification for triple lumen haemodialysis catheter, size: 12.5 f material: thermosensitive polyurethane material no of lumen: 3 (three). third lumen must be usable for drug delivery, cvp monitoring, transfusions. third lumen must be of 19g diameter. all the lumens must be marked with priming flow rate preferrable laser etched. common hub must be reinforced to reduce kinking of lumens. catheter shaft must be marked with depth markings for ease of insertion. lumen must be of modified double-d design for consistence flow even during low arterial pressure. main shaft must have laser cut side slot. tip must be symmetrically designed. guidewire: j tipped nitinol core kink free guide wire with thumb advancer needle: 18g introducer needle/18 g safety introducer needle. dilator: 2 in number, 10 f and 12 f. package: sterile pack must contain the followings: beside catheter, needle, dilators, guidewire 5/6 ml luer lock syringe. retractable safety scalpel fenestrated drape large 2.0/1.0 nylon suture with cutting needle. antiseptic applicator wand. island dressing 2 in number/ or transparent wound dressing 6-8 sterile gauze sponges 3 sealing caps. desirable inclusion in the pack: a pair of gloves, dressing gown.,triple lumen hemodailysis catheter (curved), specification for triple lumen hae modialysis catheter, size: 12.5 f material: thermosensitive polyurethane material no of lumen: 3 (three ). third lumen must be usable for drug delivery, cvp monitoring, transfusions. third lumen must be of 19g diameter. all the lumens must be marked with priming flow rate preferrable laser etched. common hub mu st be reinforced to reduce kinking of lumens. catheter shaft must be marked with depth markings for ease of insertion. lumen must be of modified double-d design for consistence flow even during low arterial pres sure. main shaft must have laser cut side slot. tip must be symmetrically designed. guidewire: j tipped niti nol core kink free guide wire with thumb advancer needle: 18g introducer needle/18 g safety introducer ne edle. dilator: 2 in number, 10 f and 12 f. package: sterile pack must contain the followings: beside cathete r, needle, dilators, guidewire 5/6 ml luer lock syringe. retractable safety scalpel fenestrated drape large 2. 0/1.0 nylon suture with cutting needle. antiseptic applicator wand. island dressing 2 in number/ or transpar ent wound dressing 6-8 sterile gauze sponges 3 sealing caps. desirable inclusion in the pack: a pair of glov es, dressing gown. [ai(2025-26) , item code no.s-58108, sl. no.568] ] => limited
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download d0ad7fe1-d78e-4fc2-9f70-2d58969b6405
Download File Name File Description
Download 5c7e7772-fdf8-4433-a96e-0b67a117d0cc Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000