BRR : 8354558
Tender Brief : Tender For Supply And Installation Of Street Lights At Various Locations In Mahaveer Enclave Ii/Iii In Ac-30 Janakpuri Under Mcd West Zone.; 1 Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Inputvoltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >8... Read More
Tender Value
₹
9,40,840
Contract Value
₹ 7,31,974
Saving / Difference
₹ 2,08,866
▲
Submission Date
17-11-2025
Contract Date
21-11-2025
Completion Date
120 days
Participated Bidder List
10 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 7,72,523.72 | L5 | |||
| 2 | cnet-technologies | Bid Analytics | 7,38,088.98 | L2 | |||
| 3 | cnet-technologies | Bid Analytics | 7,67,725.44 | L4 | |||
| 4 | cnet-technologies | Bid Analytics | 7,78,921.44 | L6 | |||
| 5 | cnet-technologies | Bid Analytics | 7,31,974 | L1 | |||
| 6 | cnet-technologies | Bid Analytics | 7,64,338.42 | L3 | |||
| 7 | cnet-technologies | Bid Analytics | 7,81,838.04 | L7 | |||
| 8 | cnet-technologies | Bid Analytics | 8,36,218.59 | L9 | |||
| 9 | cnet-technologies | Bid Analytics | 8,45,815.16 | L10 | |||
| 10 | cnet-technologies | Bid Analytics | 7,87,953.5 | L8 |
Work Detail
tender for supply and installation of street lights at various locations in mahaveer enclave ii/iii in ac-30 janakpuri under mcd west zone.; 1 supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, inputvoltage: 140-270 volt ac, freq 50/60 hz, operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-4- 5, driver efficiency >85%,thd < 10% as per iec 61000-3-2 , p. f.≥0.95, ip66,ik-10, cri >80 , under voltage and over voltage protection,emiemc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000°k /4000°k / 5700°k /6000°k/6500°k (as per ansi bin) , sdcm(standard deviation color matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standardcomplete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy >135 lm/wattoutput . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermalmanagement: heat sink of aluminum housing such that led junction temperature shall not rise above 90°c). 72 watt 2 supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd. 3 supply of xlpe insulated pvc sheathed al. conductor armoured cable 1.1 kv grade confirming to is 7098/1988 of following sizes (a) 2x4 sqmm 4 supplying and drawing following size of frls pvc insulated copper conductor, single core cable in the existing surface/recessed steel/pvc conduit as required. 3 x 1.5 sqmm 5 laying of one number pvc insulated and pvc sheathed/xlpe power cable of 1.1 kv grade of following size in the existing masonary open ducts as required. upto 35 sq. mm
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 7103Schedule | Tender Documents |
| Download | BOQ_293631 | Tender Documents |
| Download | Tendernotice_1 | Tender Documents |
| Download | 5f729c15-5c55-4b5e-9833-6d08c933e78c | Tender Documents |
| Download | 7103Conditions | Tender Documents |
| Download | 7103DNIT | Tender Documents |
| Download | 7103GCC | Tender Documents |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000