BRR : 8303481
Click Here To View Tendering Authority. Aoc City/State :  ramgarh, Haryana
Tender Brief : Tender For Installation Of Recd Device In Existing Dg At Zone-Iii To Zone-Viii At Tbrl Range Ramgarh; 1 Supply, Installation, testing and commissioning of retrofit emission control devicefor 50.0 kVAdiesel generator of any make/vintage, heat resistant, corrosion resistance material with engineered clamp mechanism for quick service with bypass arrangement alongwithPCD control panel (Telematics) to monitor back pressure and temperature, indicates health alarms, Emergency shut down, remote monitoring,facilitates after sale-service and identify any issues incl cutting and welding existing exhaus... Read More
Tender Value
44,17,000
Contract Value
₹ 25,02,165
Saving / Difference
₹ 19,14,835 ▲
Submission Date
13-09-2025
Contract Date
21-11-2025
Completion Date
180 days
Participated Bidder List
11 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 37,00,000 L8
2 cnet-technologies Bid Analytics 27,46,307 L2
3 cnet-technologies Bid Analytics 27,47,200 L3
4 cnet-technologies Bid Analytics 27,48,400 L4
5 cnet-technologies Bid Analytics 39,85,000 L10
6 cnet-technologies Bid Analytics 39,50,000 L9
7 cnet-technologies Bid Analytics 25,02,165 L1
8 cnet-technologies Bid Analytics
9 cnet-technologies Bid Analytics 28,50,000 L6
10 cnet-technologies Bid Analytics 28,21,744.62 L5
11 cnet-technologies Bid Analytics 35,92,864 L7
Work Detail
tender for installation of recd device in existing dg at zone-iii to zone-viii at tbrl range ramgarh; 1 supply, installation, testing and commissioning of retrofit emission control devicefor 50.0 kvadiesel generator of any make/vintage, heat resistant, corrosion resistance material with engineered clamp mechanism for quick service with bypass arrangement alongwithpcd control panel (telematics) to monitor back pressure and temperature, indicates health alarms, emergency shut down, remote monitoring,facilitates after sale-service and identify any issues incl cutting and welding existing exhaust pipe, removing existing silencer a supply and fixingflange,welding, nut, bolts, washers etc, as per existing exhaust pipecomplete all as specified and directed. application :- reduce particulate matter (pm) , carbon monoxide (co) and hydrocarbons (hc) emissions from diesel generators. improve air quality. compliance with caqm (direction no. 76) and cpcb regulations.device must be compliance with caqm (direction no. 76) and cpcb regulations.testing:-(a) .adhering to this, recd to be tested’ for an equivalent kva family as per the system and procedure from any one of the five central pollution control board, govt, of india, recognized/approved test agencies/laboratories as given below: 2 (a)automotive research association of india (arai, pune)(b) international centre for automotive testing (icat, manesar(c)indian institute of petroleum (iip, dehradun)(d) vehicle research development establishment (vrde, ahmednagar)(e) indian oil corporation, research and development centre, faridabad (haryana)(b). the contractor shall demonstrate compliance of the recd type or recd family with the provision of the regulation.note: type approval certificate shall be produced before installation of the recd for equivalent kva family. 3 back pressure due to the emission control retrofit device :- recd shall be have no effect on exhaust back pressure. the back pressure shall be maintained within prescribed limit by the manufacturer. there should not be any back flow from recd to engine exhaust system. approval of recd for family of dg sets should be as per cpcb instructions and the same has to be obtained from the cpcb prescribed labs as above. the recd manufacturer shall furnish written instructions and requirements about use and maintenance of recd system, its correct operation and maintenance and its emission performance. 4 scope of installation: - (a) installation of emission control retrofit device when offered by the vendor is inclusive in the scope of supply and shall be done by the contractor. the installation work of emission control retrofit device. (b) cutting, welding, removing existing exhaust system, nut, bolts, washers, flanges, are incl in quoted rates.(c) ms items for support and fixing are incl in quoted rates.(d) construction of suitable earthing station and necessary connections shall be done by the contractor.warranty/service;- 12 monthsnumber of preventive maintenance visits in a year during warranty period :- 2 visits 5 all as per serial item no 1 above but for dg set of capacity 180 kva -ditto-. 6 all as per serial item no 1 above but for dg set of capacity 200 kva -ditto-. 7 all as per serial item no 1 but for dg set of capacity 320 kva -ditto-.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download a08ce44c-4c77-4d5d-a96c-af6d86b4a449
Download AOC75
Download boqcomparativechart
Download finance_814169
Download finsummary_814169
Download technical_814169
Download techsummary_814169
Download File Name File Description
Download Tenderdocuments75 Tender Documents
Download Tendernotice_1 Tender Documents
Download 970c426a-9ba6-4ac4-a81f-cfec0241cb31 Tender Documents
Download BOQ_814169 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders