BRR : 8187287
Tender Brief : Servicing of Air Condition machines installed at Mayurakshi Bhawan & SCADA building at Massanjore, MCC combined office building, rest shed at Suri (I) colony and SCADA Building at Tilpara Barrage, during the year 2025-26.- 1 Comprehensive Annual Maintenance and servicing of Air conditioning machine of following ratings. 2 i) 1.0 Ton split type 3 ii) 1.5 Ton split & Cassette type both. 4 iii) 2.0 Ton split & Cassette type both 5 Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectificatio... Read More
Tender Value
₹
2,72,058
Contract Value
₹ 2,69,201.62
Saving / Difference
₹ 2,856
▲
Submission Date
24-07-2025
Contract Date
31-10-2025
Completion Date
365 days
Participated Bidder List
4 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 2,77,499.4 | L3 | |||
| 2 | cnet-technologies | Bid Analytics | 2,72,194.26 | L2 | |||
| 3 | cnet-technologies | Bid Analytics | 2,69,201.62 | L1 | |||
| 4 | cnet-technologies | Bid Analytics | 2,80,219.98 | L4 |
Work Detail
servicing of air condition machines installed at mayurakshi bhawan & scada building at massanjore, mcc combined office building, rest shed at suri (i) colony and scada building at tilpara barrage, during the year 2025-26.- 1 comprehensive annual maintenance and servicing of air conditioning machine of following ratings. 2 i) 1.0 ton split type 3 ii) 1.5 ton split & cassette type both. 4 iii) 2.0 ton split & cassette type both 5 gas charging (r410a/eco friendly green gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 6 i) 1.5 tr. 7 ii) 2.0 tr. 8 providing & fixing of isi marked (is : 15778 - 2007) rigid cpvc drain water piping 6 kg/ cm2 with fittings like elbow, socket, tee etc& support with ms hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect, 20mm dia. 9 supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 tr/2 tr/3 tr capacity including brazing, nitrile rubber insulation 6/9mm thick class o, etc complete as required, copper tube 3/8.
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000