BRR : 7961579
Tender Brief : Annual Plan-Thiruvali Grama Panchayath Repair of Highmast and related activities-S0290/26 -General Electrical Work-- 1 wiring 2 OD463235/2024-2025:Dismantling the existing damagedunserviciable flood lightt from the mast Supply Conveyance, installation, testingandcommissioningof150 W LEDFloodlight output greaterthan luninious efficiency as per companysspecifications, withIP65protectionLEDChipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 4 KV, power consumption 150W+, 10%,,and Aluminium pressure die-cast Powder coated housing, acryl... Read More
Tender Value
₹
1,46,000
Contract Value
₹ 1,22,920
Saving / Difference
₹ 23,080
▲
Submission Date
25-08-2025
Contract Date
17-09-2025
Completion Date
180 days
Participated Bidder List
1 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 1,22,920.34 | L1 |
Work Detail
annual plan-thiruvali grama panchayath repair of highmast and related activities-s0290/26 -general electrical work-- 1 wiring 2 od463235/2024-2025:dismantling the existing damagedunserviciable flood lightt from the mast supply conveyance, installation, testingandcommissioningof150 w ledfloodlight output greaterthan luninious efficiency as per companysspecifications, withip65protectionledchipmake cree/lumilled/nichea with power factor greater than 0.95 at full load, internal surge protection up to 4 kv, power consumption 150w+, 10%,,and aluminium pressure die-cast powder coated housing, acrylic cover complete with thd lessthan 10%, power factor greater than 0.98, rohs compliant,die cast alumanium body &toughnrd glass, rated life 5000hrs, working temperature 0to 50 degrees duly wired up for use on 230v acsupply.drivercompartmentshouldbeseperatly accessibleformaintenance and giving connections as reuired[ dismantled unservicable flood lights, solar panel, battery etc to be returned to the agreement authority with reciepts] 3 90.6.5.11:supply and drawing the following sizes of multi-core pvc insulated & frlspvc sheathed 650/1100 v grade copper conductor round flexible cables conforming to is 694 part i 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm 4 od462393/2024-2025:supplyandfixingoffollowingsizesofcorrugated pvc flexible conduit alongwithaccessoriesin surface/recess of proposed pole andmakinggoodthesameincaseofrecessed conduit as required 25 mm corrugated pvc flexible conduit 5 1.17.20:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.2 x 4 sq. mm 6 od462394/2024-2025: supply conveyance, installation, testingandcommissioningof g 25a, 2pole, ac 1 rated power contactor with 1no+1nc auxiliary contacts & with ac coil 7 od462385/2024-2025: supply conveyance, installation, testingandcommissioningof 24 hours analog timer for operating automatic on-off function 8 od462392/2024-2025:supply and fixing danger notice board of size, 125 x 75 mm 9 2.10.3:supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.double pole 10 2.14.2:supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (rccb), having a sensitivity current upto 300 milliamperes in the existing mcb db complete with connections, testing and commissioning etc. as required.40 amps 11 5.4:earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 12 od462396/2024-2025:5 mm x 3 mm g.i. strip earth lead supplying and providing and fixing 25 mm x 3 mm g.i. strip earth lead from the test joint to the earth plate 13 od462384/2024-2025:supply and installation and commissining of dust and vermin proofsyntax meter board gs-mb-4537-nf and to fix kseb meters, fuse units,n/lct, rccb etcas required including fixing it on wall, making good the damages colour washing etc. as required. 14 od462387/2024-2025:supplying and fixing32 a, 2 way neutral links mounted on dmc/smc base with connections, in existing meter board 15 od462390/2024-2025:supplying and fixing32a, hrc fuse with hrc fuse link with connections, in existing meter board 16 od462389/2024-2025:charges for procurement, preparation and submission of application for availing single/three phase kseb service connection with necessary sketch, test and completion report, etc. including necessary liaison work as required
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 18791025-2743-46d4-a952-583f9def4642 | Tender Documents |
| Download | BOQ_1281804 | Tender Documents |
| Download | Declaration | Tender Documents |
| Download | epaymentform | Tender Documents |
| Download | nit125 | Tender Documents |
| Download | preliminary | Tender Documents |
| Download | Tendernotice_1 | Tender Documents |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results