BRR : 7851986
Tender Brief : Tender For Auxiliary And Exhaust Boilers Jobs Onboard The Vessel Rm 0815; 1 Auxiliary and Exhaust Boilers jobs onboard the Vessel RM.0815, Oil fired 2 SERVICE PART 3 E 25028 : AUXILIARY AND EXHAUST BOILERS (SURVEY). 4 OIL FIRED AUX. BOILERS (1 NOS.) MAKE: KANGRIM TYPE 25000KG/HR7 BAROIL BURNER TYPE: STEAM ATOMISING OIL BURNER TYPE:-DF505 5 E 20028. 7, ALL CUTOUTS & TRIPS TO BE TRIED OUT FOR SAFTY VALVES 6 E 20028. 35, 37. FD FAN DAMPER PNEUMATIC ACTUATOR OPERATION SLUGGISHSAME TO CHECK & DEFECT TO RECTIFY.AIR SUPPLY UNIT WITH REDUCING VALVE AND FILTER TO CHECK/REPAIR IF DEFECT NOTICED. ... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 2,30,850
Submission Date
07-07-2025
Contract Date
23-08-2025
Completion Date
20 days
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 2,30,850 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | 24,50,000 | L3 | |||
| 3 | cnet-technologies | Bid Analytics | 10,57,230 | L2 |
Work Detail
tender for auxiliary and exhaust boilers jobs onboard the vessel rm 0815; 1 auxiliary and exhaust boilers jobs onboard the vessel rm.0815, oil fired 2 service part 3 e 25028 : auxiliary and exhaust boilers (survey). 4 oil fired aux. boilers (1 nos.) make: kangrim type 25000kg/hr7 baroil burner type: steam atomising oil burner type:-df505 5 e 20028. 7, all cutouts & trips to be tried out for safty valves 6 e 20028. 35, 37. fd fan damper pneumatic actuator operation sluggishsame to check & defect to rectify.air supply unit with reducing valve and filter to check/repair if defect noticed. parts required to be quoted. 7 water level control system for aux. blr. maker:kangrim heavy industry co. ltd. koreamodel mb06s01 8 e 20028. 55, aux boilers water level transmitterscontrollersv/v positioners to overhaul and calibrate. 9 e 20028. 56, 4.1) one no. feed water control v/vs to overhaul. 10 e 20028. 57, 4.2) remote level indicators in e.c.r. to check and calibrate. 11 e 20028. 58, 4.3) remote /manual operation of control v/v by potentiometer to check. 12 e 20028. 59, 4.4) satisfactory operation of system in auto & manual mode to be shown to ceo/supdt after overhauling. 13 combustion system for oil fired aux. boilers. 14 e 20028. 60,5.1) auto combustion control system completely to be serviced by makers service engineer.oxygen content of flue gases to be adjusted at different load conditions to give colourless smoke discharge & 2 to 3 % oxygen content. 15 e 20028. 61, 5.2) air/oil controller fuel oil temp controller and master pressure controller to checkservice and settings to adjust as required. 16 e 20028. 62, 5.3) fd fan i.p. positioner pneaumatic actuator to overhaul & positioner to configure and initilised.f.d fan limit switches to be calibrated. 17 e 20028. 63, 5.4) plc batteries to check and renew as required. 18 e 20028. 64, 5.5) satisfactory working of above system in auto & emergency modesfor both aux boilers to be shown to ceo/supdt. 19 e 25034 : control valves 20 following v/vscontrollersactuatorspositioners to be overhauledcalibrated and satisfactory working shown to ceo/supdt.spares if any reqd. to be quoted. aa) temperature control valves - maker korval.e 20034. 10,10) aux boiler f.o heatermodel : kcr-dppneumatic diaphragm typeactuator model no : k03-r1range 0-150 deg.bb)pressure control v/vs - maker korval 21 e 20034. 12, 12) excess steam ( dump v/v ) 22 e 25087 miscellaneous repair jobs 23 e25087.17,15. aux boiler low low water levelfloat gets punctured too often because of thislow lowwater level trip doesn’t work . same to be rectified using ships spare 24 material part 25 e 25028 : auxiliary and exhaust boilers (survey). 26 oil fired aux. boilers (1 nos.) make: kangrim type 25000kg/hr7 baroil burner type: steam atomising oil burner type:-df505 27 e 20028. 7, all cutouts & trips to be tried out for safty valves 28 e 20028. 35, 37. fd fan damper pneumatic actuator operation sluggishsame to check & defect to rectify.air supply unit with reducing valve and filter to check/repair if defect noticed. parts required to be quoted. 29 water level control system for aux. blr. maker:kangrim heavy industry co. ltd. koreamodel mb06s01 30 e 20028. 55, aux boilers water level transmitterscontrollersv/v positioners to overhaul and calibrate. 31 e 20028. 56, 4.1) one no. feed water control v/vs to overhaul. 32 e 20028. 57, 4.2) remote level indicators in e.c.r. to check and calibrate. 33 e 20028. 58, 4.3) remote /manual operation of control v/v by potentiometer to check. 34 e 20028. 59, 4.4) satisfactory operation of system in auto & manual mode to be shown to ceo/supdt after overhauling. 35 combustion system for oil fired aux. boilers. 36 e 20028. 60,5.1) auto combustion control system completely to be serviced by makers service engineer.oxygen content of flue gases to be adjusted at different load conditions to give colourless smoke discharge & 2 to 3 % oxygen content. 37 e 20028. 61, 5.2) air/oil controller fuel oil temp controller and master pressure controller to checkservice and settings to adjust as required. 38 e 20028. 62, 5.3) fd fan i.p. positioner pneaumatic actuator to overhaul & positioner to configure and initilised.f.d fan limit switches to be calibrated. 39 e 20028. 63, 5.4) plc batteries to check and renew as required. 40 e 20028. 64, 5.5) satisfactory working of above system in auto & emergency modesfor both aux boilers to be shown to ceo/supdt. 41 e 25034 : control valves 42 following v/vscontrollersactuatorspositioners to be overhauledcalibrated and satisfactory working shown to ceo/supdt.spares if any reqd. to be quoted. aa) temperature control valves - maker korval.e 20034. 10,10) aux boiler f.o heatermodel : kcr-dppneumatic diaphragm typeactuator model no : k03-r1range 0-150 deg.bb)pressure control v/vs - maker korval 43 e 20034. 12, 12) excess steam ( dump v/v ) 44 e 25087 miscellaneous repair jobs 45 e25087.17,15. aux boiler low low water levelfloat gets punctured too often because of thislow lowwater level trip doesn’t work . same to be rectified using ships spare
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results