Tender Result - Tender For supply installation testing and commissioning Of Ac Machines At Bank Building (1St Floor) At Makaut, Haringhata Campus, Nadia.- 1 Supply of 1.5/1.6 TonSplit type A.C. machine having the following specification & features:- a) Cooling capacity (Maximum) (BTU/HR): 18080; cooling capacity (Rated) Guaranteed (BTU/HR):18000, b) Star Rating -3 star, c) Rated Voltage - 230 V + / - 5%, Frequency - 50 Hz, d) Compressor type -Rotary, e) Mini. Room Discharge Air Flow Rate-950CMH, f) Refrigerant: R-410A/R-32, g) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low / Medium / High) Auto Swing, h) Out door operating Temperature:- 50 C (Minimum), i) PCB control unit of indoor unit should be covered by metallic enclosure. (Make- O-General / Mitsubishi - Heavy/Daikin/Carrier ) 2 Supply of 2/1.95 TonSplit type A.C. machine having the following specification & features:- a) Cooling capacity (Maximum) (BTU/HR): 24240; cooling capacity (Rated) Guaranteed (BTU/HR):24000, b) Star Rating -3 star, c) Rated Voltage - 230 V + / - 5%, Frequency - 50 Hz, d) Compressor type -Rotary, e) Mini. Room Discharge Air Flow Rate-1150CMH, f) Refrigerant: R-410A/R-32, g) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low / Medium / High) Auto Swing, h) Out door operating Temperature:- 50 C (Minimum), i) PCB control unit of indoor unit should be covered by metallic enclosure. (Make - O-General / Mitsubishi - Heavy/Daikin/Carrier ) 3 Installation, Testing and commissioning of 1.5/1.95/2.0 Tr. Split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut-bolt etc. & mending good the damages. 4 Supply & laying of following sizes Refrigerant Copper Pipe (Make- Royku / Totaline / Mandeep) with insulation by nitril rubber also raping the insulation & Copper wire with GKB Gold non adhesive tape.(a) 6.35 mm (1/4) dia incl.(b)15.88 mm (5/8) dia including Supply & drawing of 1.1 KV Gr.3 core 2.5 Sq.mm. PVC insulated sheathed Copper wire (Make- Havells / Finolex / Polycab) for connecting the outdoor to indoor unit supply. 5 Supply & laying 3/4 heavy type PVC pipe for Water Drainage as per direction. 6 Supply & fixing of 3 pin 16/20 A plug top with indicator. ( Make - PWD Approved)

Tender Detail

7587612
Public Works Department
Tender For supply installation testing and commissioning Of Ac Machines At Bank Building (1St Floor) At Makaut, Haringhata Campus, Nadia.- 1 Supply of 1.5/1.6 TonSplit type A.C. machine having the following specification & features:- a) Cooling capacity (Maximum) (BTU/HR): 18080; cooling capacity (Rated) Guaranteed (BTU/HR):18000, b) Star Rating -3 star, c) Rated Voltage - 230 V + / - 5%, Frequency - 50 Hz, d) Compressor type -Rotary, e) Mini. Room Discharge Air Flow Rate-950CMH, f) Refrigerant: R-410A/R-32, g) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low / Medium / High) Auto Swing, h) Out door operating Temperature:- 50 C (Minimum), i) PCB control unit of indoor unit should be covered by metallic enclosure. (Make- O-General / Mitsubishi - Heavy/Daikin/Carrier ) 2 Supply of 2/1.95 TonSplit type A.C. machine having the following specification & features:- a) Cooling capacity (Maximum) (BTU/HR): 24240; cooling capacity (Rated) Guaranteed (BTU/HR):24000, b) Star Rating -3 star, c) Rated Voltage - 230 V + / - 5%, Frequency - 50 Hz, d) Compressor type -Rotary, e) Mini. Room Discharge Air Flow Rate-1150CMH, f) Refrigerant: R-410A/R-32, g) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low / Medium / High) Auto Swing, h) Out door operating Temperature:- 50 C (Minimum), i) PCB control unit of indoor unit should be covered by metallic enclosure. (Make - O-General / Mitsubishi - Heavy/Daikin/Carrier ) 3 Installation, Testing and commissioning of 1.5/1.95/2.0 Tr. Split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut-bolt etc. & mending good the damages. 4 Supply & laying of following sizes Refrigerant Copper Pipe (Make- Royku / Totaline / Mandeep) with insulation by nitril rubber also raping the insulation & Copper wire with GKB Gold non adhesive tape.(a) 6.35 mm (1/4) dia incl.(b)15.88 mm (5/8) dia including Supply & drawing of 1.1 KV Gr.3 core 2.5 Sq.mm. PVC insulated sheathed Copper wire (Make- Havells / Finolex / Polycab) for connecting the outdoor to indoor unit supply. 5 Supply & laying 3/4 heavy type PVC pipe for Water Drainage as per direction. 6 Supply & fixing of 3 pin 16/20 A plug top with indicator. ( Make - PWD Approved)
haringhata
West Bengal
Refer document
05-05-2025

Contract Award Details

Bidder List
Bids List
S.No Bid Number Bidder Name Submitted Date Status Remarks Status Updated On
1 111111 Dummy Name 13-Sep-2020 11:40 AM Dummy-Finance Dummy 17-Sep-2020 12:30 PM
2 111111 Dummy Name 14-Sep-2020 01:07 PM Dummy Dummy 31-May-2022 12:40 PM
Contract Date
01-01-0001
}
Contract Value
0.00
Awarded List
Awarded Bids List
S.No Bid Number Bidder Name Awarded Currency Awarded Value
1 11111 Dummy Dummy 0
}
Additional Details Available on Click
✓ Bidder List
✓ Contract Value
✓Awarded List

Tender Results Documents

Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail