BRR : 7342139
Tender Brief : Repairing And Rectification Of Motor Starter Panel Works Including Supplying Required Materials At Different W/S Scheme Under Harishchandrapur I Adjacent Block Under Malda Mechanical Division, Phe Dte.- 1 Charges for thorough checking of PLC panel by qualified personnel for fault detection as per direction of EIC. 2 Supply and delivery of thefollowing at site for motor starter panel. 3 Konar ph - II 4 32 Amp Contactor (Siemens/L&T/Other approved make) 5 Add on Contact Block . (make siemens/L&T /Other equivalent approved) 6 Star delta timer as per existing sample ( Make minilac or approv... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 2,24,286
Submission Date
07-03-2025
Contract Date
13-05-2025
Completion Date
14 days
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 2,26,735.18 | L3 | |||
| 2 | cnet-technologies | Bid Analytics | 2,24,286 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | 2,24,589.94 | L2 |
Work Detail
repairing and rectification of motor starter panel works including supplying required materials at different w/s scheme under harishchandrapur i adjacent block under malda mechanical division, phe dte.- 1 charges for thorough checking of plc panel by qualified personnel for fault detection as per direction of eic. 2 supply and delivery of thefollowing at site for motor starter panel. 3 konar ph - ii 4 32 amp contactor (siemens/l&t/other approved make) 5 add on contact block . (make siemens/l&t /other equivalent approved) 6 star delta timer as per existing sample ( make minilac or approved) 7 96 sq mm digital volt meter.(make-ae /other approved) 8 led type indicating lamp (red, yellow, green(make- siemens / other approved) 9 auxiliary contactor (2no+2nc).(make :siemens/other approved) 10 water level controller make minilac or other approved 11 gannadia ph - i 12 32 amp contactor (siemens/l&t/other approved make) 13 add on contact block . (make siemens/l&t /other equivalent approved) 14 16 amp contactor (siemens/l&t/other approved make) 15 240 volt 24 hours electronic digital timer . (make-gic or other equivalent approved) 16 on dealy timer (make:gic or other approved) 17 star delta timer as per existing sample ( make minilac or approved) 18 96 sq mm digital volt meter.(make-ae /other approved) 19 led type indicating lamp (red, yellow, green(make- siemens / other approved) 20 gannadia ph - ii 21 32 amp contactor (siemens/l&t/other approved make) 22 40 amp contactor (siemens/l&t/other approved make) 23 16 amp contactor (siemens/l&t/other approved make) 24 add on contact block . (make siemens/l&t /other equivalent approved) 25 star delta timer as per existing sample ( make minilac or approved) 26 alv d2 phase failure relay - alv d2 (make-minilec 27 spgd2 (make-minilec or other approved) 28 led type indicating lamp (red, yellow, green(make- siemens / other approved) 29 on dealy timer (make:gic or other approved) 30 240 volt 24 hours electronic digital timer . (make-gic or other equivalent approved) 31 rangaipur ph - i 32 32 amp contactor (siemens/l&t/other approved make) 33 add on contact block . (make siemens/l&t /other equivalent approved) 34 star delta timer as per existing sample ( make minilac or approved) 35 on dealy timer (make:gic or other approved) 36 240 volt 24 hours electronic digital timer . (make-gic or other equivalent approved) 37 6 amp tp mcb (make siemens/l&t /other equivalent approved) 38 6 amp sp mcb (make siemens/l&t /other equivalent approved) 39 96 sq mm digital volt meter.(make-ae /other approved) 40 96 sq mm digita ammeter .(make-ae /other approved) 41 led type indicating lamp (red, yellow, green(make- siemens / other approved) 42 dk. mahendrapur ph - ii 43 40 amp contactor (siemens/l&t/other approved make) 44 add on contact block . (make siemens/l&t /other equivalent approved) 45 auxiliary contactor (2no+2nc).(make :siemens/other approved) 46 led type indicating lamp (red, yellow, green(make- siemens / other approved) 47 harishchandrapur ph - iii 48 40 amp contactor (siemens/l&t/other approved make) 49 add on contact block . (make siemens/l&t /other equivalent approved) 50 star delta timer as per existing sample ( make minilac or approved) 51 240 volt 24 hours electronic digital timer . (make-gic or other equivalent approved) 52 water level controller make minilac or other approved 53 alv d2 phase failure relay - alv d2 (make-minilec 54 96 sq mm digital volt meter.(make-ae /other approved) 55 96 sq mm digita ammeter .(make-ae /other approved) 56 led type indicating lamp (red, yellow, green(make- siemens / other approved) 57 dhanjana ph - i 58 32amp contactor (siemens/l&t/other approved make) 59 alv d2 phase failure relay - alv d2 (make-minilec 60 spgd2 (make-minilec or other approved) 61 1/20 ct 62 add on contact block . (make siemens/l&t /other equivalent approved) 63 240 volt 24 hours electronic digital timer . (make-gic or other equivalent approved) 64 repairing of the existing panel by fitting of the above supplied materials in existing position after necessary disconnection of power line and dismentling of the damaged or non serviceable spares,and by supplying all fixing materials such as screws, nut-bolts, washers, cable tie, pvc tape, sockets etc. as per direction of eic 65 add gst @ 18% 66 add cess @ 1%
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results