BRR : 7281925
Tender Brief : Tender For Work Of Residual Life Assessment Test Of 100 Mva (Cgl Make) T/F-Ii At 220/132/33 Kv S/S Faridpur Under E.T.D., Bareilly - 1- Online Testing to be conducted on Transformer .(A) 1- Online Partial Discharge Measurment.2- Thermographic Measurement.3- Noise Level Measurement.4- Vibration Level Measurement.5- Oil Test (NABL Approved Lab):(i)- General Oil test as par IS 1866:2000 (Resistivity, Tan dalta,BDV, Water PPM, IFT,Acidity,Flash point & Sludge content)(ii)- DGA as per relevant IEC(iii)- Furan analysis2- Offline Testing to be conducted on Transformer:(i)-Capacitance & tan Delta of... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 1,10,000
Submission Date
16-04-2025
Contract Date
25-04-2025
Completion Date
15 days
Participated Bidder List
5 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | 1,79,974 | L2 | |||
| 4 | cnet-technologies | Bid Analytics | 1,10,000 | L1 | |||
| 5 | cnet-technologies | Bid Analytics | 2,45,000 | L3 |
Work Detail
tender for work of residual life assessment test of 100 mva (cgl make) t/f-ii at 220/132/33 kv s/s faridpur under e.t.d., bareilly - 1- online testing to be conducted on transformer .(a) 1- online partial discharge measurment.2- thermographic measurement.3- noise level measurement.4- vibration level measurement.5- oil test (nabl approved lab):(i)- general oil test as par is 1866:2000 (resistivity, tan dalta,bdv, water ppm, ift,acidity,flash point & sludge content)(ii)- dga as per relevant iec(iii)- furan analysis2- offline testing to be conducted on transformer:(i)-capacitance & tan delta of bushing & windings.(ii)- turn ratio at each taps.(iii)- vector group test.(iv)-short circuit impedance test.(v)- magnetizing current on each tap.(vii)- magnetic balance test.(viii) ir & pi test.(ix)- sweep frequency response analysis test & mechanical assessment.(x)- frequency response on stray loss test(frsl)(xi)-leakage reactance &impendance measurement.(xii)-dynamic contact resistance test for oltc performance check.(xiii)- moisture assessment & dielectric analysis of winding insulation (fds measurement)
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results