BRR : 5631996
Tender Brief : Bids Are Invited For 1Boq - Determining Sbc Of Soil By Performing Necessary Tests Such As Spt / Dcpt As Per 2131-1981 Whichever Is Suitable. Also Recommend The Type Of Fdn And Sbc Of Soil At Certain Depth By Performing Bore Hole Up To 6.0M Depth With 01 Nos Each Trial Pit Of ( Size 1.2X1.2X3.0M Depth ) 5.0 Mtr Away From Bore Hole ( Both Centrally Placed ) Or Refusal Whichever Is Earlier Alongwith Spt At 1.0M In Bore Hole. Collection Of Soil Sample ( Disturbed / Undisturbed ) Their Complete Lab Testing As Per Relevant Is Code Taking Sswl ( If Encounter ) And Other E... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 2,44,200
Submission Date
23-05-2022
Contract Date
Ref. Document
Completion Date
Ref. Document
Participated Bidder List
5 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 4,90,000 | L3 | |||
| 2 | cnet-technologies | Bid Analytics | 6,04,700 | L5 | |||
| 3 | cnet-technologies | Bid Analytics | 2,44,200 | L1 | |||
| 4 | cnet-technologies | Bid Analytics | 4,82,000 | L2 | |||
| 5 | cnet-technologies | Bid Analytics | 5,93,000 | L4 |
Work Detail
bids are invited for 1boq - determining sbc of soil by performing necessary tests such as spt / dcpt as per 2131-1981 whichever is suitable. also recommend the type of fdn and sbc of soil at certain depth by performing bore hole up to 6.0m depth with 01 nos each trial pit of ( size 1.2x1.2x3.0m depth ) 5.0 mtr away from bore hole ( both centrally placed ) or refusal whichever is earlier alongwith spt at 1.0m in bore hole. collection of soil sample ( disturbed / undisturbed ) their complete lab testing as per relevant is code taking sswl ( if encounter ) and other engineering and index properties and evaluation of soil within capacity and chemical analysis of soil samples to determine ph value, sulphate and chlorides as is 456 / 2000 complete all as specified and as per is. , 2boq - determining sbc of soil by performing necessary tests such as spt / dcpt as per 2131-1981 whichever is suitable. also recommend the type of fdn and sbc of soil at certain depth by performing bore hole up to 10.0m depth with 01 nos each trial pit of ( size 1.2x1.2x3.0m depth ) 5.0 mtr away from bore hole ( both centrally placed ) or refusal whichever is earlier alongwith spt at 1.0m in bore hole. collection of soil sample ( disturbed / undisturbed ) their complete lab testing as per relevant is code taking sswl ( if encounter ) and other engineering and index properties and evaluation of soil within capacity and chemical analysis of soil samples to determine ph value, sulphate and chlorides as is 456 / 2000 ( for rcc frame structure of double / triple storey bldgs ) complete all as specified and as per is. , 3boq - determining sbc of soil by performing necessary tests such as spt / dcpt as per 2131-1981 whichever is suitable. also recommend the type of fdn and sbc of soil at certain depth by performing bore hole up to 15.0m depth with 01 nos each trial pit of ( size 1.2x1.2x3.0m depth ) 5.0 mtr away from bore hole ( both centrally placed ) or refusal whichever is earlier alongwith spt at 1.0m in bore hole. collection of soil sample ( disturbed / undisturbed ) their complete lab testing as per relevant is code taking sswl ( if encounter ) and other engineering and index properties and evaluation of soil within capacity and chemical analysis of soil samples to determine ph value, sulphate and chlorides as is 456 / 2000 ( for rcc frame structure swt / ug sump etc ) complete all as specified and as per is. , 4boq - determining sbc of soil by performing necessary tests such as spt / dcpt as per 2131-1981 whichever is suitable. also recommend the type of fdn and sbc of soil at certain depth by performing bore hole up to 22.0m depth with 01 nos each trial pit of ( size 1.2x1.2x3.0m depth ) 5.0 mtr away from bore hole ( both centrally placed ) or refusal whichever is earlier alongwith spt at 1.0m in bore hole. collection of soil sample ( disturbed / undisturbed ) their complete lab testing as per relevant is code taking sswl ( if encounter ) and other engineering and index properties and evaluation of soil within capacity and chemical analysis of soil samples to determine ph value, sulphate and chlorides as is 456 / 2000 ( structure for ohr etc ) complete all as specified and as per is. , 5boq - plate load test for bldg having base are more than 4000sqm and ohr / gsr of capacity more than 5000 gallen addition to normal filed and lab tests on uds / ds samples complete all as specified as per is. total quantity : 33
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 986f0ed5-d3de-451d-8408-852167d05558 |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results