BRR : 5151856
Tender Brief : Supply Of Generator 250 Kva , Supply, Installation, Testing And Commissioning Of 250 Kva Diesel Generator Except The Following , Rcc Foundation For Housing The Dg Set ( Above 62.5 Kva ) In Theratio 1:2:4 ( M-20 Grade ) With 20Mm Metal, 10 Mm Reinforcement On Both Sides 15 Cm C / C And Cement Plastering. ( Foundation Should Be Constructed By Providing Additional 1 Feet Extension Of The Dg Dimension On Each Side. Also The The Height Of Foundation Should Be 30 Cm Above Ground Level ) , Supply Of Suitable Size Extra Ms Exhaust Line As Per Standard Including Factory Made Bends, Flange... Read More
Tender Value
₹
23,25,000
Contract Value
₹ 1,60,157
Saving / Difference
₹ 21,64,843
▲
Submission Date
21-10-2021
Contract Date
12-07-2022
Completion Date
56 days
Participated Bidder List
1 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 32,03,130 | L1 |
Work Detail
supply of generator 250 kva , supply, installation, testing and commissioning of 250 kva diesel generator except the following , rcc foundation for housing the dg set ( above 62.5 kva ) in theratio 1:2:4 ( m-20 grade ) with 20mm metal, 10 mm reinforcement on both sides 15 cm c / c and cement plastering. ( foundation should be constructed by providing additional 1 feet extension of the dg dimension on each side. also the the height of foundation should be 30 cm above ground level ) , supply of suitable size extra ms exhaust line as per standard including factory made bends, flanges, nut, bolt and necessary supports and covered with laying of glass wool and cladding with aluminium with accessories pipe and silencer wherever necessarysuitable for dg set supplied. ( per meter ) , 4 nos of copper plate earthing pits required for the dg set including construction of earth chamber and covering with heavy duty cast ironcover hinged to cast iron frame includingproviding and fixing 25 mm x 3 mm copper strip on surface or in recess for connections etc. as required. the distancebetween 2 pits shall beminimum 3 metres , all the electrical connections to the existing busbar / system through change over switch and commissioning with suitable cableof size 1.1 kv grade 2x185 sq mm 4 core ( per meter ) . the laying of cable shall be as per the ksei standards, which includes laying directly on wall surface ( clamped with 40 x 3mm ms flat clamp ) , all the electrical connections to the existing busbar / system through change over switch and commissioning with pvc insulated and pvc sheathed armoured aluminium power cable of 1.1 kv grade size 2x185 sqmm 4 core ( per meter ) . laying of cable in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering , all the electrical connections to the existing busbar / system through change over switch and commissioning with pvc insulated and pvc sheathed armoured aluminium power cable of 1.1 kv grade size 2x185sq mm 4 core ( per meter ) . laying of cable in in the rcc / hume / stone ware / gi / dwc pipe as required ( for road crossing etc ) , all the electrical connections to the existing busbar / system through change over switch and commissioning with pvc insulated and pvc sheathed armoured aluminium power cable of 1.1 kv grade size 2x185sq mm 4 core ( per meter ) . laying of cable on factory made perforated trays ( 300mm width and 50mm depth ) with required bends. , canopy with 0.35mm thick powder coated gi sheet for the safeguard of dg set and enclosure to control panels. the sheet should be extended to 90 cm from the foundation on all sides. truss work shall be with gi frame work sufficient to withstand the sheet roofing and the shall be neatly painted.minimum height of canopy shall be 3.6 mtrs from the foundation. , all statutory approval from electrical inspectorate, spcb, local bodies etc and the same is to be regularized from kseb , supply and installation of generator amf control panel with required size of mccb as incomer each for mains and dg supply , contactors of required specifications, necessary indication lamps, control switches, fuses, push bottons, voltmeter, ammeter, frequency meter etc , supply and laying of 12c x 2.5 sq.mm copper cable for amf control cabling , supply and laying of 4c x 2.5 sq.mm copper cable for amf control cabling , supply and installation of 400a 4 pole manual changeover switch for necessarry by-pass arrangement if required. ( mains supply by-pass ) , the epoxy coating for all the metallic parts of the dg set and its components in costal areas ( not taken for evaluation )
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | e24896e9-4194-40f5-8f00-19d144cc72d5 |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results