BRR : 5130297
Click Here To View Tendering Authority. Aoc City/State :  CDLU, Sirsa, Haryana
Tender Brief : Supply Of Equipment Differential Scanning Calorimeter For University Science Instrumentation Centre Under Rusa Grant.- Supplying, Installation, Testing and Commissioning of Differential Scanning Calorimeter (DSC) with following specifications. n nI. Principle of operation: Heat Flux, System provide raw data without mathematical treatment / deconvolution / smoothening / baseline correction. nII. Heat flow measurements in Static as well as Dynamic Gas Atmospheres essential. nIII. Temperature range: -25°C to 700°C with RCS in a single run (RCS should serviceable in India). nIV. Furance: Low ma... Read More
Tender Value
Ref. Document
Contract Value
₹ 36,20,012
Submission Date
24-02-2021
Contract Date
07-08-2024
Completion Date
45 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 48,91,950 L3
2 cnet-technologies Bid Analytics 46,90,350 L2
3 cnet-technologies Bid Analytics 36,20,012 L1
Work Detail
supply of equipment differential scanning calorimeter for university science instrumentation centre under rusa grant.- supplying, installation, testing and commissioning of differential scanning calorimeter (dsc) with following specifications. n ni. principle of operation: heat flux, system provide raw data without mathematical treatment / deconvolution / smoothening / baseline correction. nii. heat flow measurements in static as well as dynamic gas atmospheres essential. niii. temperature range: -25°c to 700°c with rcs in a single run (rcs should serviceable in india). niv. furance: low mass furnace made of silver for rapid heating/cooling and resistant to corrosion. nv. temp. accuracy : +/- 0.2°c or better temp. accuracy : +/- 0.2°c or better nvi. temp. precision : +/- 0.02°c or better nvii. furnace temp. resolution : 0.00006°c or better nviii. heating rate : 0.02 to 250°c/min or better nix. controlled cooling rate : 0.02 to 50°c/min nx. pressure : ambient nxi. sensor: ceramic, chemical resistant, corrosion resistant, exchangeable type heat flow measurement with multiple-thermocouples (more than 100) offering low signal time constant of 1.8s or better. nxii. the sensor should not an integral part of the furnace and the sensor should easily replaceable nxiii. resolution : >16 million points, 0.04µw nxiv. data sampling rate: max. 50 values per second nxv. system should not need recalibration when changing crucible, gases and heating rates. nxvi. purge gas : inert, reactive & static. nxvii. dsc amplifier range : +/- 350mw or better nxviii. accuracy of enthalpy measurement : <1% indium nxix. crucibles: 40µl aluminium crucibles (1000nos.) with a sealing press. nxx. gas controller: inbuilt nxxi. data acquisition/processing system: windows based software should enable automatic / manual on-line data acquisition and display of running measurements, calibration. the multi-tasking software should facilitate storage of both raw dsc data as well as deconvoluted data in the form of standard dsc curves. the s/w should have the facility of choosing different baseline e.g. line, tangential, horizontal, spline, integral tangential, polygon line etc. for correct evaluation/ integration of peaks. options for baseline correction, data smoothening, plot expansion, curve overlay unlimited, font selection etc. should be provided. storage of results in tabular form (ascii format) should be facilitated. nxxii. the system have provision for future up gradation with microscopy-dsc measurements with visual observation: simultaneous image analysis and dsc measurements – provide a complete thermal picture of the sample with microscopy system. nxxiii. nitrogen cylinder with ss regulator & flow meter should be supplied with the instrument. nxxiv. suitable pc & laser printer should be supplied with the instrument. nxxv. suitable ups should quoted as optional. nxxvi. factory trained engineers kindly specify nos. with their branch wise location. nxxvii. application lab should be in india with qualified personnel to assist in case of application related queries. n item1 1 each
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download cd22ca68-03e2-41f3-a733-1e912ca8e07f
Download boqcomparativechart
Download committee
Download finance_213008
Download finsummary_213008
Download techsummary_213008
Download File Name File Description
Download BOQ_213008 Tender Documents - Financial Bid
Download 19838BD6-3AED-4926-BFE5-58FAD1CBA6CA Tender Documents - Tender Notice
Download Tendernotice_1 Tender Documents - DNIT
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders