BRR : 4768189
Tender Brief : Tender For Increasing Capacity Of 33 / 11Kv S / S Kadar Chowk From 2X5 Mva To 10+5 Mva In District Badaun.; 1 Loading, Unloading And Safe Carriage Of The Following Materials From Any Electy. Store Center Of Electricity Store Division Of Bareilly Zone. 2 33 Kv Lightening Arrester 3 Control Pannel I / C For 33 Kv Single T / F 4 11 Kv 3X300 Mm2 Xlpe Cable 5 11 Kv Cable Jointing Kit 3X300 Mm2 I / D 6 11 Kv Cable Jointing Kit 3X300 Mm2 O / D 7 Earthing Of Indoor & Outdoor Equipments Of Sub-Station After Proper Welding Of Joints And Painting Of Earth Strip Above Soil With Pro... Read More
Tender Value
₹
3,40,000
Contract Value
₹ 3,39,250
Saving / Difference
₹ 750
▲
Submission Date
10-11-2023
Contract Date
21-12-2023
Completion Date
90 days
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 3,66,420 | L2 | |||
| 2 | cnet-technologies | Bid Analytics | 3,39,250 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | 3,39,250 | L1 |
Work Detail
tender for increasing capacity of 33 / 11kv s / s kadar chowk from 2x5 mva to 10+5 mva in district badaun.; 1 loading, unloading and safe carriage of the following materials from any electy. store center of electricity store division of bareilly zone. 2 33 kv lightening arrester 3 control pannel i / c for 33 kv single t / f 4 11 kv 3x300 mm2 xlpe cable 5 11 kv cable jointing kit 3x300 mm2 i / d 6 11 kv cable jointing kit 3x300 mm2 o / d 7 earthing of indoor & outdoor equipments of sub-station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per respo approved drawing & resistance of earthing should be not more than 2o as per details given below. 8 making of triangular bridge by using ms electrode, gi strip 50x6mm and gi pipe 40 mm dia with providing of well type pipe earthing upto 15 mtr. depth below ground level including welding etc. by boaring process at t / f neutral, la and newly erected structure including cost of gi pipe of size 40 mm dia 15 mtr. long of isi mark. ( all the required material will be supllied by the contractor ) . 9 supply of gi strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. all la will be seprately earth also as per respo norms. ( all the required materials will be provided by firm. ) 10 installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure. 11 33 kv lightening arrestor 12 dismantling of existing following damage equipments on their structure. 13 33 kv lightening arrestor 14 complete laying and termination of copper control cables from 10 mva power t / f, existing 33 kv vcb & 33 kv ct in the out door switch yard to new double transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per resspo drawings, including cost of testing of transformer, vcb, ct, relay pannel & proper relay settings as per requirement etc. 15 control cable 4x2.5 mm2 16 control cable 2x2.5 mm2 17 laying of 11kv cable of different size from power t / f to control room i / c . 11 kv cable will be layed in brick trench constructed below 750mm to the ground level over the ganga sand. brick trench will be constructed by ist class bricks covering three sides of cable, after laying 11 kv cable brick trench will be filed by ganga sand & then will be covered by bricks & backfill of soil over cable trench as per respo norms. 18 termination of 11 kv 3x300sqmm size xlpe cable by filling 11 kv heat shrinkable type cable boxes. 19 erection & testing of 1 no. double t / f control panel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control rooms tranches by river sand. 20 repairing of existing 33 kv vcb at kadar chowk sub-station including replacement of all required accessories as motor, intrruptor etc. all type of material should be provided by the firm. 21 safely shifting and dragging of 33 / 11 kv 10 mva transformer from its safe site to plinth at sub-station alongwith its erection including fixing of all assessories and top-up of t / f oil. 22 safely shifting and dragging of 33 / 11 kv 5 mva transformer from its plinth to safe site at sub-station. 23 carriage of old scrap material from site to store center badaun. 24 complete repairing of switchyard fencing.
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results