BRR : 3949829
Tender Brief : Purchasing Influenza Rt- Pcr Kit , Viral Rna Extraction Kit Of Vrdl Microbiology Department For R G Kar Medical College , Influenza Rt-Pcr Kit Specification: 1. The Kit Should Be Ce-Ivd Approved. 2. The Kit Should Be Multiplex One-Step Taqman Pcr Based. 3. The Kit Should Work On Rna Isolated From Sputum , Balf, Oropharyngeal And Nasal Swabs In Vtm 4. The Kit Should Detect Flu-A, Flu-B, Flu-C, H1n1 , H3n2 And H5n1 In A 2-Tube Multiplex Pcr Reaction 5. The Kit Run Time Should Not Exceed 1 Hr 20 Mins 6. The Kit Should Be Compatible With Appliedbiosystems@7500/7500 Fast Real-Time Pcr System , Qua... Read More
Tender Value
₹
5,00,000
Contract Value
₹ 66,500
Saving / Difference
₹ 4,33,500
▲
Submission Date
02-04-2024
Contract Date
12-04-2024
Completion Date
15 days
Participated Bidder List
7 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics | 71,800 | L2 | |||
| 5 | cnet-technologies | Bid Analytics | 75,600 | L3 | |||
| 6 | cnet-technologies | Bid Analytics | 66,500 | L1 | |||
| 7 | cnet-technologies | Bid Analytics |
Work Detail
purchasing influenza rt- pcr kit , viral rna extraction kit of vrdl microbiology department for r g kar medical college , influenza rt-pcr kit specification: 1. the kit should be ce-ivd approved. 2. the kit should be multiplex one-step taqman pcr based. 3. the kit should work on rna isolated from sputum , balf, oropharyngeal and nasal swabs in vtm 4. the kit should detect flu-a, flu-b, flu-c, h1n1 , h3n2 and h5n1 in a 2-tube multiplex pcr reaction 5. the kit run time should not exceed 1 hr 20 mins 6. the kit should be compatible with appliedbiosystems@7500/7500 fast real-time pcr system , quanstudio 5, bio-rad cfx96 , qiagen rotor gane q, roche lighcycler@480 , analytik jena qtower-g touch series real time pcr platforms. 7. no cross-reactivity with related viruses like rsv, covid-19, metapneumovirus and parainfluenza virus 1-4 should be noted. , viral rna extraction kit specification: 1. the kit should be ce-ivd approved. 2. the kit should be used for the isolation of rna viruses like covid-19, rsv and influenza viruses 3. the kit should use magnetic bead based automated rna extraction in kingfisher flex-96 machine with documented evidence for the same. 4. proteinase – k and other lytic reagents should be included in the lysis buffer and not to be added separately . 5. the entire process should take less than 30 mins per isolation for a batch of 5 samples. 6. sample volume should be 200ul with elution volume 50ul
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results