BRR : 3811692
Click Here To View Tendering Authority. Aoc City/State :  aurangabad, Maharashtra
Tender Brief : Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad. Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad. , Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasahebambedkar Marathwada University Aurangabad. , Wall Panel & Partition Panel 50 Mm Thick Pufinsulated Thick Panel With 0.45Mm Ppgi Sheet Both Sides In 40±2 Kg Density. Puf Panel Shall Bemanufactured By Using High Quality Huntsmans Chemicals &... Read More
Tender Value
Ref. Document
Contract Value
₹ 41,55,000
Submission Date
09-03-2023
Contract Date
22-03-2024
Completion Date
365 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 41,55,000 L1
2 cnet-technologies Bid Analytics 45,54,800 L2
3 cnet-technologies Bid Analytics 46,63,500 L3
Work Detail
supply, erection of pre-fab insulated partition for dna barcoding building at dr.babasaheb ambedkar marathwada university aurangabad. supply, erection of pre-fab insulated partition for dna barcoding building at dr.babasaheb ambedkar marathwada university aurangabad. , supply, erection of pre-fab insulated partition for dna barcoding building at dr.babasahebambedkar marathwada university aurangabad. , wall panel & partition panel 50 mm thick pufinsulated thick panel with 0.45mm ppgi sheet both sides in 40±2 kg density. puf panel shall bemanufactured by using high quality huntsmans chemicals & n pantane as a blowing agent. thepu panel shall be cfc free and zero ozonedepleting panel made out of continuous line running on uninterrupted power supply. panel shall have pre coated gisheet on both side of polyurethane foam confirming to is 12436:1988. the pre coated sheet shall be ofminimum 240 mpa steel grade confirming to is 14246:1995 and shall have zinc coating of minimum 120gsm as per is : 277 : 1992, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. the ppgi sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. the panels shall be vertically joined together by tongue and groove joints. the pu foam shall be self-extinguishing, fire retardant type having minimum density of 40 kg/cu.mt (+, -2 kgs). partition windows should be provided as per requirement. , supplying and erecting prefabricated door for labortory puf insulated room complete air tight of size 1.7 m (w) x 2.1m (h) made from 0.5 mm thick p.p. sheet on both sides having sandwiched puf insulation of 40 kg/mtr cube density, thermal conductivity less than 0.02 wb/mtr cube and 50 mm thickness complete installing alongwith the door frame firmly to the cold room panels having non corrosive handles, locks, hinges, heaters in door leaf and frame, audio alarm for door open condition, auto lock and release mechanism in an approve manner. , supplying and erecting prefabricated door for labortory puf insulated room complete air tight of size 1.2 m (w) x 2.1m (h) made from 0.5 mm thick p.p. sheet on both sides having sandwiched puf insulation of 40 kg/mtr cube density, thermal conductivity less than 0.02 wb/mtr cube and 50 mm thickness complete installing alongwith the door frame firmly to the cold room panels having non corrosive handles, locks, hinges, heaters in door leaf and frame, audio alarm for door open condition, auto lock and release mechanism in an approve manner. , supplying and erecting prefabricated door for labortory puf insulated room complete air tight of size 0.900 m (w) x 2.1336 m (h) made from 0.5 mm thick p.p. sheet on both sides having sandwiched puf insulation of 40 kg/mtr cube density, thermal conductivity less than 0.02 wb/mtr cube and 50 mm thickness complete installing alongwith the door frame firmly to the cold room panels having non corrosive handles, locks, hinges, heaters in door leaf and frame, audio alarm for door open condition, auto lock and release mechanism in an approve manner. , supplying and erecting prefabricated door forlabortory puf insulated room complete air tight of size 0.762 m (w) x 2.1336 m (h) made from 0.5 mm thick p.p. sheet on both sides having sandwiched puf insulation of 40 kg/mtr cube density, thermal conductivity less than 0.02 wb/mtr cube and 50 mm thickness complete installing alongwith the door frame firmly to the cold room panels having non corrosive handles, locks, hinges, heaters in door leaf and frame, audio alarm for door open condition, auto lock and release mechanism in an approve manner.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 2023_BAMU_871492_3WO
Download 783142e9-bc5c-4dcf-a477-17a439aad8e6
Download boqcomparativechart
Download finsummary_1517542
Download techsummary_1517542
Download File Name File Description
Download 3f997ae8-9773-4633-9ada-ea15dadd6e02 Tender Documents
Download BOQ_1517542 Tender Documents
Download partition Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders