BRR : 3511724
Tender Brief : supply of Testing Of Oil In Power Transformers Testing Of Oil In Power Transformers , Items : , Physical Condition And Appearance Of The Oil. ( Is 335 ) Spec: Physical Condition And Appearance Of The Oil ( Is 335 ) . Testing Of Oil In Power Transformers Installed At Various Substations Through Outside Agency. As Per Attached Specification. , Density At Room Temperature { Is:1448 ( P-16 ) } . Spec: Density At Room Temperature { Is:1448 ( P-16 ) } . Testing Of Oil In Power Transformers Installed At Various Substations Through Outside Agency. As Per Attached Specification. , Resisti... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 1,11,510
Submission Date
07-11-2022
Contract Date
28-12-2022
Completion Date
270 days
Participated Bidder List
5 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 10,856 | L5 | |||
| 2 | cnet-technologies | Bid Analytics | 1,11,510 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | 5,900 | L2 | |||
| 4 | cnet-technologies | Bid Analytics | 7,080 | L4 | |||
| 5 | cnet-technologies | Bid Analytics | 6,962 | L3 |
Work Detail
supply of testing of oil in power transformers testing of oil in power transformers , items : , physical condition and appearance of the oil. ( is 335 ) spec: physical condition and appearance of the oil ( is 335 ) . testing of oil in power transformers installed at various substations through outside agency. as per attached specification. , density at room temperature { is:1448 ( p-16 ) } . spec: density at room temperature { is:1448 ( p-16 ) } . testing of oil in power transformers installed at various substations through outside agency. as per attached specification. , resistivity of the oil at room temperature & at 90 degree centigrade ( is:6103 ) . spec: resistivity of the oil at room temperature & at 90 degree centigrade ( is:6103 ) .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , dissipation factor of the oil ( is:6262 ) at room temperature & at 90 degree centigrade spec: dissipation factor of the oil ( is:6262 ) at room temperature & at 90 degree centigrade.testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , electric bd voltage ( is:6792 ) at room temperature using 2.5 mm gap spec: electric bd voltage ( is:6792 ) at room temperature using 2.5 mm gap.testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , inter facial tension of the oil ( is:6104 ) against water at room temperature spec: inter facial tension of the oil ( is:6104 ) against water at room temperature. testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , water content ( ppm ) by karl fischer method ( is:13567 ) spec: water content ( ppm ) by karl fischer method ( is:13567 ) .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , neutralisation value ( total acidity ) of the oil { ( is:1448 ( p-2 ) } . spec:neutralisation value ( total acidity ) of the oil { ( is:1448 ( p-2 ) } .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , sediment & perceptible sludge { ( is:1866 ( ap-a ) } . spec: sediment & perceptible sludge { ( is:1866 ( ap-a ) } . testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , flash point { ( is:1448 ( p-21 ) } . spec: flash point { ( is:1448 ( p-21 ) } .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , dissolved gas analysis for total gas content ( tgc ) and concentration of component gases as per is:9434 spec: dissolved gas analysis for total gas content ( tgc ) and concentration of component gases as per is:9434.testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , furan analysis as per astm-d:5837 spec:furan analysis as per astm-d:5837. testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , sample collection charges ( per sample ) spec: sample collection charges ( per sample ) . testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , purchase of various size , link clips
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | c4cd9f7f-9b46-4868-8dad-70743fc683c3 |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results