BRR : 3511724
Click Here To View Tendering Authority. Aoc City/State :  mazagaon, Maharashtra
Tender Brief : supply of Testing Of Oil In Power Transformers Testing Of Oil In Power Transformers , Items : , Physical Condition And Appearance Of The Oil. ( Is 335 ) Spec: Physical Condition And Appearance Of The Oil ( Is 335 ) . Testing Of Oil In Power Transformers Installed At Various Substations Through Outside Agency. As Per Attached Specification. , Density At Room Temperature { Is:1448 ( P-16 ) } . Spec: Density At Room Temperature { Is:1448 ( P-16 ) } . Testing Of Oil In Power Transformers Installed At Various Substations Through Outside Agency. As Per Attached Specification. , Resisti... Read More
Tender Value
Ref. Document
Contract Value
₹ 1,11,510
Submission Date
07-11-2022
Contract Date
28-12-2022
Completion Date
270 days
Participated Bidder List
5 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 10,856 L5
2 cnet-technologies Bid Analytics 1,11,510 L1
3 cnet-technologies Bid Analytics 5,900 L2
4 cnet-technologies Bid Analytics 7,080 L4
5 cnet-technologies Bid Analytics 6,962 L3
Work Detail
supply of testing of oil in power transformers testing of oil in power transformers , items : , physical condition and appearance of the oil. ( is 335 ) spec: physical condition and appearance of the oil ( is 335 ) . testing of oil in power transformers installed at various substations through outside agency. as per attached specification. , density at room temperature { is:1448 ( p-16 ) } . spec: density at room temperature { is:1448 ( p-16 ) } . testing of oil in power transformers installed at various substations through outside agency. as per attached specification. , resistivity of the oil at room temperature & at 90 degree centigrade ( is:6103 ) . spec: resistivity of the oil at room temperature & at 90 degree centigrade ( is:6103 ) .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , dissipation factor of the oil ( is:6262 ) at room temperature & at 90 degree centigrade spec: dissipation factor of the oil ( is:6262 ) at room temperature & at 90 degree centigrade.testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , electric bd voltage ( is:6792 ) at room temperature using 2.5 mm gap spec: electric bd voltage ( is:6792 ) at room temperature using 2.5 mm gap.testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , inter facial tension of the oil ( is:6104 ) against water at room temperature spec: inter facial tension of the oil ( is:6104 ) against water at room temperature. testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , water content ( ppm ) by karl fischer method ( is:13567 ) spec: water content ( ppm ) by karl fischer method ( is:13567 ) .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , neutralisation value ( total acidity ) of the oil { ( is:1448 ( p-2 ) } . spec:neutralisation value ( total acidity ) of the oil { ( is:1448 ( p-2 ) } .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , sediment & perceptible sludge { ( is:1866 ( ap-a ) } . spec: sediment & perceptible sludge { ( is:1866 ( ap-a ) } . testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , flash point { ( is:1448 ( p-21 ) } . spec: flash point { ( is:1448 ( p-21 ) } .testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , dissolved gas analysis for total gas content ( tgc ) and concentration of component gases as per is:9434 spec: dissolved gas analysis for total gas content ( tgc ) and concentration of component gases as per is:9434.testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , furan analysis as per astm-d:5837 spec:furan analysis as per astm-d:5837. testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , sample collection charges ( per sample ) spec: sample collection charges ( per sample ) . testing of oil in power transformers installed at various substations through outside agency.as per attached specification. , purchase of various size , link clips
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download c4cd9f7f-9b46-4868-8dad-70743fc683c3
Download File Name File Description
Download ea98d05f-ad1a-4889-a47c-115d67702b11 Tender Documents
Download BOQ_1459046 Tender Documents
Download Tendernotice_1 Tender Documents
Download Tendernotice_2 Tender Documents
Download TestingofoilTenderdoc Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders