BRR : 3388225
Click Here To View Tendering Authority. Aoc City/State :  peechi, Kerala
Tender Brief : Supply And Installation Of Refrigerated Centrifuge , Refrigerated Centrifuge , Technical Specifications For Supply And Installation Of Refrigerated Centrifuge 1. Type And Make: Refrigerated Benchtop Centrifuge • Aerosol Tight Fixed Angle Rotor With Capacity To Accommodate A Minimum 20 Numbers Of 1.5 / 2 Ml Microfuge Tubes To Be Supplied With Centrifuge • Adaptor Sets For 0.2Ml Pcr Tubes And 0.5Ml / 0.6Ml Microlitre Tubes To Be Supplied • Instrument Should Have Option For Easily Changing Rotor To Swinging Bucket, And Or Microplate Or Fixed Angle Rotor ( 15 / 50Ml Tube ) At La... Read More
Tender Value
6,00,000
Contract Value
₹ 4,11,015
Saving / Difference
₹ 1,88,985 ▲
Submission Date
22-01-2024
Contract Date
04-06-2024
Completion Date
15 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 4,25,000 L2
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics 4,11,015 L1
Work Detail
supply and installation of refrigerated centrifuge , refrigerated centrifuge , technical specifications for supply and installation of refrigerated centrifuge 1. type and make: refrigerated benchtop centrifuge • aerosol tight fixed angle rotor with capacity to accommodate a minimum 20 numbers of 1.5 / 2 ml microfuge tubes to be supplied with centrifuge • adaptor sets for 0.2ml pcr tubes and 0.5ml / 0.6ml microlitre tubes to be supplied • instrument should have option for easily changing rotor to swinging bucket, and or microplate or fixed angle rotor ( 15 / 50ml tube ) at later stage • must have wide temperature range of -11°c to + 40°c ( refrigerated ) , which can be adjustable during the run operation • must be able to maintain at 4°c at max. speed. • max speed of more than 12, 000 rpm, max rcf more than of 20, 000g • centrifuge must have a “fast cool” function where cooling process can be shortened • must have automatic temperature start up at a specific time to automatically pre- prepare temperature before centrifugation • acceleration time to maximum speed must be less than 14s for all rotors at max load and a deceleration time of less than 15s with the standard1.5 / 2ml rotor, but has option to accelerate and decelerate gently for sensitive samples using specific key. • centrifuge should have running time option for continuous run • power requirements: 230v, 50-60 hz, if stabilizer is required it must come with instrument 2. general features: • must have digital display of time, speed and temperature • programmable time and speed using jog dials / keypad • must be able to store 50 routine procedures with 5 programmable buttons for frequently used programs in the first level • able to switch display between rcf and rpm speed setting • separate short spin key • low noise levels less than 63db at max speed • brushless maintenance free drive • automatic motorised locking when lid almost closed 3. safety features: • iec 61010-2-020 or ce / ul certified for safety and compliance with international standards • rotor should be made of anodised aluminium to ensure chemical resistance • chamber must be of stainless steel material • any rotors, caps, buckets and adaptors supplied must be must be autoclavable at 121°c for 20min to completely eliminate any contaminating material • aerosol tightness should be certified by external body • automatic imbalance detection • automatic rotor recognition • 2-point lid screwing for maximum security even at high speed centrifugation • it should have built-in condensation drain to eliminate excess water to prevent corrosion. • should use cfc free refrigerant 4.warranty - two-year comprehensive on-site warranty ( minimum ) . 5. documentation should include user / technical / maintenance manuals, list of important spares and accessories with their part number and price and list of recent end-users in centrally or state funded research / academic institutes in kerala or other parts of india. 6.readily available service support based in kerala from manufacturer ( support document to be submitted from manufacturer side ) 7.the vendor needs to provide the address of certified and authorized service center for the quoted equipment in / nearest to thrissur, kerala. 8.the equipment should be installed, tested and demonstrated on-site at the requested location by authorized service agents of the manufacturer / vendor. 9.the equipment should be delivered at kfri sub centre, kuzhur, kakkulissery, kuzhur p. o. thrissur, kerala – 680734.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 43d460d8-aeca-41d0-87e3-c68924b5f524
Download boqcomparativechart
Download finance_981481
Download finsummary_981481
Download PO
Download technical_981481
Download techsummary_981481
Download File Name File Description
Download d335c2d5-97a0-4e66-87d2-6f2d19868b90 Tender Documents
Download Tendernotice_1 Tender Documents
Download AGREEMENT Tender Documents
Download BOQ_981481 Tender Documents
Download tenderdoc Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders