BRR : 2517907
Tender Brief : Supply Of Mri Conditional Pacing System With Accessories For Delivery Of Cardiac Resynchronization Therapy., ( Sr Ph Code 154080 ) Mri Conditional Pacing System With Accessories For Delivery Of Cardiac Resynchronization Therapy. System Should Include A Current Generation Mri Conditional Crt Pulse Generator, Bipolar Steroid-Eluting Atrial And Ventricular Leads And A Quadripolar Left Ventricular ( Coronary Sinus ) Lead And Accessories ( Lead Introducers, Sheaths Or Guiding Catheters Etc., ) . Should Provide Independently Programmable Right And Left Ventricular Pulse Outputs And Inter... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 10,45,955.4
Submission Date
09-10-2023
Contract Date
17-11-2023
Completion Date
Ref. Document
Participated Bidder List
1 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 10,45,955.4 | L1 |
Work Detail
supply of mri conditional pacing system with accessories for delivery of cardiac resynchronization therapy., ( sr ph code 154080 ) mri conditional pacing system with accessories for delivery of cardiac resynchronization therapy. system should include a current generation mri conditional crt pulse generator, bipolar steroid-eluting atrial and ventricular leads and a quadripolar left ventricular ( coronary sinus ) lead and accessories ( lead introducers, sheaths or guiding catheters etc., ) . should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, left ventricular alone or biventricular pacing as well as the choice of which ventricle is to be paced first with optimization of delay for pacing of other ventricle ) . should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrial tachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. unit:no
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 51696daa-8161-4c93-bcfb-f27530e91407 |
| Download | File Name | File Description |
|---|---|---|
| Download | 48397251-8bde-4ff8-a77b-7a9f2f58a740 | Tender Documents |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results