BRR : 2263826
Tender Brief : Re E Tender For Procurement Of Additional Consumable Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Cemented Total Hip Replacement System With Accessories: Cemented Thr System -Acetabular Cup Size 40 To 62 Made Of Highly Cross-Linked Polyethylene ( Range 7 – 10 Mard ) , Stem Made Of Forged Cocr, Base Diameter 4Mm To 8Mm, & Internal Head Having Minimum 5 Nos Offset. Total Instruments Set For Thr System Should Be On Loaner Basis. Certification : Us Fda / Ce Certified From Notified Body. , Uncemented Total Hip Repalcement System: Uncemented Total Hip Replacement Sys... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 1
Submission Date
23-05-2022
Contract Date
07-11-2022
Completion Date
730 days
Participated Bidder List
4 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | 1 | L1 | |||
| 4 | cnet-technologies | Bid Analytics |
Work Detail
re e tender for procurement of additional consumable items for two years from the date of award of contract ( aoc ) , cemented total hip replacement system with accessories: cemented thr system -acetabular cup size 40 to 62 made of highly cross-linked polyethylene ( range 7 – 10 mard ) , stem made of forged cocr, base diameter 4mm to 8mm, & internal head having minimum 5 nos offset. total instruments set for thr system should be on loaner basis. certification : us fda / ce certified from notified body. , uncemented total hip repalcement system: uncemented total hip replacement system acetabular cup size 40 to 62 made of titanium and having porous coating & highly crosslink polyethylene liner, ha coated stem base diameter 4mm to 8mm made of titanium, 28 / 32 mm sst / cocr internal head, total instruments set for thr system. instruments set should be on loaner basis. certification : us fda / ce certified from notified body. , femoral component metallurgy - cocr ( cobalt chromium molybdenum ) . femur should have a deep trochlear grove. femoral component with various a / p diameter & m / l diameter, with different polythickness . titanium anatomical tibia with different m / l diameter& a / p diameter. poly insert metallurgy - highly cross linked 5-7.5 mrad width different insert thickness, patella thickness 9 mm. instruments set should be on loaner basis. certification : us fda / ce certified from notified body. , total knee replacement system with zirconium oxide femoral component: femoral component metallurgy - zirconium oxide. femur should have a deep trochlear grove. femoral component with various a / p diameter & m / l diameter, with different polythickness . titanium anatomical tibia with different m / l diameter& a / p diameter. poly insert metallurgy - highly cross linked 5-7.5 mrad width different insert thickness, patella thickness 9 mm. instruments set should be on loaner basis. certification : us fda / ce certified from notified body.
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 5c519500-2cbf-4d74-8d49-8b34e3e40060 |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results