BRR : 1992507
Click Here To View Tendering Authority. Aoc City/State :  DAMAN, Daman And Diu
Tender Brief : Provision Of Soil Testing For Asr With Mssr Building At Icgas Daman , ( 1 ) Boring Hole As Shown On Drg 150 Mm Dia By Rotory Drilling In Soil And 75Mm To 100Mm Dia In Rock For Investigation In Any Type Of Soil / Rock / Concrete Floors And Sub Bases Refusal Including Boulders Weathered Rock Upto A Depth Of 15 Mtrs Or 5 Mtrs In Rock Each Or As Directed By Engr-In-Charge Alongwith Spt At Every 1 . 50M , Any Carrying Out Spt And Other Tests Required For Designing The Foundation Of High Rise Bldgs For Installation Of Asr With Mssr Likely Affect On Hill Lock By Erecting By The Structure ... Read More
Tender Value
1,20,000
Contract Value
₹ 1,14,000
Saving / Difference
₹ 6,000 ▲
Submission Date
17-11-2020
Contract Date
03-12-2020
Completion Date
45 days
Participated Bidder List
6 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 2,40,000 L6
2 cnet-technologies Bid Analytics 1,19,994 L3
3 cnet-technologies Bid Analytics 1,19,998 L4
4 cnet-technologies Bid Analytics 1,20,000 L5
5 cnet-technologies Bid Analytics 1,19,800 L2
6 cnet-technologies Bid Analytics 1,14,000 L1
Work Detail
provision of soil testing for asr with mssr building at icgas daman , ( 1 ) boring hole as shown on drg 150 mm dia by rotory drilling in soil and 75mm to 100mm dia in rock for investigation in any type of soil / rock / concrete floors and sub bases refusal including boulders weathered rock upto a depth of 15 mtrs or 5 mtrs in rock each or as directed by engr-in-charge alongwith spt at every 1 . 50m , any carrying out spt and other tests required for designing the foundation of high rise bldgs for installation of asr with mssr likely affect on hill lock by erecting by the structure at the location adjacent to civil buildings . ( 2 ) test report should included all the test as required for designing the foundation such as stp values , bore logs soil classifications and also should cover general recommendation for the proposed type of foundation system , safe bearing capacity likely total settlement etc . the report shall be submitted in quintuplicate duly bounded in a presentable manner . the unit rates quoted shall be deemed to included the cost of submission of such reports and sample of soil . ( 3 ) the following parameters and report will also form part of the geo-exploration report to be submitted by the soil consultants:- ( i ) recommended sbc should be given for all bore holes for minimum at three depth viz . 1 . 5 m , 2 . 0 m and 2 . 5 m . ( ii ) sbc should work out for following sizes of footings: ( a ) 1 . 5 x 1 . 5 m . ( b ) 1 . 5 x 2 . 5 m . ( c ) 2 . 0 x 2 . 5 m . ( d ) 2 . 5 x 3 . 0 m . ( e ) 3 . 0 x 3 . 0 m . ( iii ) photographic record of geo-exploration as well as testing shall also form part of the report . ( iv ) swelling index and swelling pressure in respect of black cotton soil and its depth / layer . ( v ) recommendation for filling under floors . ( 4 ) soil investigation shall be carried out as per is 1892 . soil investigation report shall include the following details:- ( i ) submission of bore hole chart . ( ii ) profile of all type bore holes . ( iii ) bearing capacity calculation indicating sbc of soil with the type of foundation and depth . ( iv ) unconsolidated and un-drained triaxial shear test . ( v ) grain size analysis , identification and classification of soil . ( vi ) unit weight ( bulk desilty ) , natural moisture content , liquid limit , plastic limit , shrinkage limit , plasticity index , specific gravity . ( vii ) dry density . degree of saturation of soil . ( viii ) free swelling index and swelling pressure if expansive soil is encountered . ( ix ) shear parameters ( c-phi analysis ) ( x ) consolidation test and permeability test . ( xi ) chemical analysis of soil . ( xii ) chemical analysis of ground water . ( water to be obtained from ( xiii ) depth of water table below ground level . ( xiv ) presence of loose soil , if any and its depth . ( xv ) if weak soil with lesser n value as specified in table-1 of is 1893 ( part-1 ) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified . ( xvi ) undisturbed soil sample shall be collected at 1 . 5 m interval and at change of strata . ( xvii ) bore hole dia shall be 150 mm , depth of bore shall be 15 . 0 m . ( xviii ) stp test shall be done at 1 . 5 m interval . ( xix ) crushing strength , degree of weathering ( cr value ) and rqd of rock sample . ( xx ) as per is-1892 clause 3 . 6 . 5 . 3 , drilling for minimum 3 . 0 m depth inside the rock is essential to ensure that boulders or layer of cemented soil are not mistaken for rock . drilling in rock will be carried out upto max 5 . 0 m . ( xxi ) for open foundations , calculation of net sbc at 1 . 5 m , 2 . 0 m , 2 . 50 m , 3 . 0 m from shear as well as settlement criteria . sbc value shall be calculated based on c-phi analysis as well as spt value . for calculations formula given in is : 6403 shall be used . ( xxii ) if pile foundation are required then depth of piles shall be mentioned and pile capacity in compression , uplift and lateral loads shall be given for 300 , 400 , 450 , 500 dia for under reamed piles & for 450 , 500 , 550 , 600 mm dia for long piles . ( xxiii ) recommendations regarding type of foundation to be adopted & net sbc / pile capacity to be adopted . also recommendations shall be given regarding stability of soil and soil stabilization required , if any . ( xxiv ) bore hole and trial pit positions duly marked on plan and their distance from adjacent prominent reference point . plan of bldgs shall also be marked in plan and signed by the consultants . ( xxv ) bore log and trial pit details shall be as per appx d of is 1892 . n values depthwise shall also be shown in bore log detail duly signed . ( xxvi ) structural effect to the foundation and stability of existing 01 no over head water tank adjacent to proposed site due to excavation and construction of new bldgs to be ascertain , and recommendation for levelling / compacting / landscaping etc to be catered as per test report . ( 5 ) no water will be supplied by the department for carry out the soil investigation test . contractor / consultant will make their own arrangement of water .
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download c6f30f59-949b-4ec6-9e06-c71b020d31b8
Download boqcomparativechart
Download JOBORDER04
Download File Name File Description
Download BOQ_437663 Tender Documents - 3006JOB4BOQ
Download Tendernotice_1 Tender Documents - 3006NIQ
Download Appx Tender Documents - APPX
Download B4E4D620-77DA-4459-B661-671867E2E89D Tender Documents - Tender Notice
Download NIQ Tender Documents - 3006TENDERDOCUMENTS
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000