BRR : 1987641
Click Here To View Tendering Authority. Aoc City/State :  GE Dronachal, Madhya Pradesh
Tender Brief : Repair And Maintenance Of Summer Appliences Repair And Maintenance Of Summer Appliences At Dronachal Bhopal , M&L For Servicing Package Type Ac Plant Of 11 Tr Capacity Of Make Blue Star With Greasing Of Motor Bearings , Replacement Of Belts , Adjustment Of Tension Of Belt , Cleaning Of All Filters , Checking Of Complete Wiring , Topup Of Gas ( Refrigerant ) , Tightening Of Nut Bolts , Oiling And Greasing Of All Movable Parts Comp [ Lete All As Specified And Up The Satisfaction Of Engr-In-Charge . ( Note : Cost Of Belt , Refrigerant Gas And Lubricant Etc Requir... Read More
Tender Value
10,00,000
Contract Value
₹ 10,00,000
Saving / Difference
₹ 0
Submission Date
20-08-2020
Contract Date
12-01-2021
Completion Date
270 days
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 7,54,575 L2
2 cnet-technologies Bid Analytics 6,73,477 L1
Work Detail
repair and maintenance of summer appliences repair and maintenance of summer appliences at dronachal bhopal , m&l for servicing package type ac plant of 11 tr capacity of make blue star with greasing of motor bearings , replacement of belts , adjustment of tension of belt , cleaning of all filters , checking of complete wiring , topup of gas ( refrigerant ) , tightening of nut bolts , oiling and greasing of all movable parts comp [ lete all as specified and up the satisfaction of engr-in-charge . ( note : cost of belt , refrigerant gas and lubricant etc required for servicing is deem to be included in unit rate and no extra cost will be paid for this separately ) . , m&l for replacement of aluminium fan blade for condensing fan motor of capacity 11tr capacity . , m&l for replacement of alumium fan blower for cooling fan motor of capacity 11tr capacity . , m&l for foam type insulating flexible pipe fitted on suction / discharge copper tubes . , s&f condenser fan motor of ductable type ac of capacity 11 tr as per existing make and model complete all as directed by engineer-in-charge . , s&f cooling fan motor of ductable split type as per existing make and model of capacity 11 tr complete all as directed by engineer-in-charge . , s & f in repairs wiring kit of package type ac plant of 11 tr capacity complete with lugs , thimble and selector switch , complete all as directed . , s & f in repairs starting / running capacitor , suitable for ductable type ac of capacity 11 tr . complete all as directed . , disconnecting dismentalling and removing of u / s condensor unit coil and s / f in replecement of condensor coil unit including conection of copper tubing for of ductable type ac 11 tr capacity all as directed . . , disconnecting dismentalling and removing of u / s cooling coil from indoor unit complete and supplying and fixing of new indoor cooling coil unit of ductable type ac of capacity of 11 tr , including connection of copper tubing all as directed . , s&f in repaired rotary type compressor of package type ac plant of 5 . 5 tr capacity with starting and running capacity and relay including connection of coppertubing and topping up of refrigerant gas for smooth functioning , complete all as directed . , supply and topping up of refrigerant gas r 22 in air conditioner at different site as required including brazing and removal of leakage in equipment , m & l for wall mounted stablizer of capacity 2 kva including fuze assy , terminal panels , indicators , time delay relay and 3 core pvc lead and re-assembling and fixing in position complete all as directed by engr in charge . , m & l for taking down wall mounted stablizer of capacity 5 kva including fuze assy , terminal panels , indicators , time delay relay and 3 core pvc lead and re-assembling and fixing in position complete all as directed by engr in charge . , s & f in repairs pcb senser unit with wire remotre control of ductable ac indoor unit of capacity 11 tr for removing old pcb and refix with new pcb of same make & capacity and model in the same position complete all as directed by engr in charge . , m & l for sub main wiring along with earth wire drown through pvc case & caping for split type a / cs with frls pvc insulated , unsheathed multi stranded copper single core cable of size 2 x 4 . 0 sqmm and 1 x 2 . 5 sqmm for earth wire including taking down old wiring all as directed . , supply & fixing single pole and neutral enclosure with a two pin and socket complete with one single pole mcb 240 volts , 32 amps , m & l for servicing of window type ac of capacity 1 . 5 / 2 tr of any make including cleaning of filter on front side by removing dust , cleaning the condenser including fins , blower fan motor and checking and testing of all parts for its serviceability , oiling / greasing to condenser cum blower fan motors , replacing worn out rubber , bushes / rubber packing , rectification of unusual noise , checking of refrigerant standing pressure , topping of refrigerant upto the required level , replacement of minor parts such as nut / bolt washers etc and reassembling of complete ac including testing for smooth functioning . complete all as directed by engineer-in-charge . , s&f in repairs aluminium fan blade suitable for condenser of window type ac of any capacity . , s&f in repairs pvc fan blower of cooling side of window type ac of any capacity . , s & f in repairs wiring kit of window type ac complete with lugs , thimble and selector switch , complete all as directed . , s&f in motor for window type ac of 1 . 5 / 2 tr capacity , complete all as directed by engineer-in-charge . , m & l for servicing of split type ac of capacity 1 . 5 / 2 tr of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building , and cleaning the complete condenser unit and cooling unit including fins , blower fan motor and checking and testing of all parts for its serviceability , oiling / greasing to condenser cum blower fan motors , remore replacing worn out rubber , bushes / rubber packing , rectification of unusal noise , checking of refrigerant standing pressure , topping of refrigerant upto the required level , replacement of minor parts such as nut / bolt washers etc and reassembling of complete ac including testing for smooth functioning complete all as directed by engineer-in-charge . , replacement of blade for condensing fan motor split type ac :- , capacitor 45 mfd , capacitor 6 mfd , capacitor 2 . 5 mfd , s & f in repairs running capacitor , 36 mfd suitable for ac of capacity 1 . 5 tr . complete all as directed . , s & f in repairs starting capacitor , 100-120 mfd suitable for ac of capacity 1 . 5 tr . complete all as directed . , m&l for removing the cooling fan motor of capacity 1 / 30 or 1 / 35 hp from split type ac , and s&f the same complete all as directed by engr-in-charge . , s&f of blower motor of capacity 1 / 30 or 1 / 20 hp split type ac 1 . 5 / 2tr . complete all as directed . , m & l for removing the unserviciable compressor sealed unit of any make from water cooler 40 / 80 ltr after cutting copper tubing without any damage to existing part , replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc , jointing of copper copper refrigerent pipe line charging gas to required level , complete including cleaning of fins , leakage testing etc including testing for smooth functioning . complete all as directed by engr in charge . , all as per item no . 32 above but compressor of water cooler of capacity 60 / 120 ltrs . , m & l for removing the unserviceable compressor sealed unit of any make from window / split type ac of capacity 1 . 5 tr after cutting copper tubing without any damage to existing parts , replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc . jointing of copper refrigerant pipe line , charging gas to required level , complete including cleaning of fins , leakage testing etc including testing for smooth functioning . complete all as directed by engineer-in-charge . , all as per item no . 34 above but for window / split type ac 2 tr capacity . , s&f in repaired compressor for deepfrizer capacity 200 / 400 ltr with relay and thermostat complete after desmantalling and disconnecting of u / s compressor and topping up of refrigerant gas upto required level all as directed . , s&f in repairs aluminium fan blade for water cooler , s&f in repairs thermostat suitable for water cooler of any capacity . , s&f in repairs waste water tray , stainless steel with coupling suitable for water cooler of capacity 40 / 80 ltrs . complete all as directed , s & f pvc drain out flexible pipe of 20mm dia 70 cms length with two mild steel clamps and necessary brass screws etc for water cooler of any size c
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download c5bb1628-0368-4eee-9b53-6087b80e539f
Download boqcomparativechart
Download 8554AOC
Download File Name File Description
Download Tendernotice_1 Tender Documents - Notice inviting tender
Download Generalpages8554 Tender Documents - Tender pages
Download BOQ_401783 Tender Documents - Price bid
Download E24407B7-50CA-498B-B957-A113FF1BE2C9 Tender Documents - Tender Notice
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000