BRR : 1894622
Click Here To View Tendering Authority. Aoc City/State :  YOL CANTT, Himachal Pradesh
Tender Brief : Providing Of Electric Energy Audit Work At Yol Cantt , Physical Inspection Of The Equipment / Installation To Observe And Comment On:- ( A ) The Compliance To Local Regulations And Local Engineering Standards . ( B ) The Extent Of Compliance To Recognized International Engineering Standards E . G . Nfpa70 , Nfpa70b , Nfpa 70E , Bs7671 , Iec60364 , Cenelec Hd384 Or Equivalent . ( C ) General Safety Requirements Of The Electrical Installation . ( D ) Basic Housekeeping And Hygiene For Electrical System . ( E ) Electrical Hazards & Adequacy Of Controls . ( F ) Rev... Read More
Tender Value
14,00,000
Contract Value
₹ 9,14,300
Saving / Difference
₹ 4,85,700 ▲
Submission Date
21-07-2020
Contract Date
02-09-2020
Completion Date
123 days
Participated Bidder List
7 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 9,14,300 L1
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics
5 cnet-technologies Bid Analytics
6 cnet-technologies Bid Analytics 10,91,000 L2
7 cnet-technologies Bid Analytics
Work Detail
providing of electric energy audit work at yol cantt , physical inspection of the equipment / installation to observe and comment on:- ( a ) the compliance to local regulations and local engineering standards . ( b ) the extent of compliance to recognized international engineering standards e . g . nfpa70 , nfpa70b , nfpa 70e , bs7671 , iec60364 , cenelec hd384 or equivalent . ( c ) general safety requirements of the electrical installation . ( d ) basic housekeeping and hygiene for electrical system . ( e ) electrical hazards & adequacy of controls . ( f ) review of compliance with implementation of hazardous area classification report , wherever applicable . ( report needs to be made available to the auditor ) ( g ) to review adequacy of inspection and testing of protective equipment and protective tools . ( i ) studying various parameters from log book dash board and instruments at the panel , cross checking ct ratios , plug multiplier setting and time multiplier setting including over current and earth fault protection . ( ii ) the load on each switchgear will be studied , its loading patten and recommendations will be funished in report . ( iii ) the energy audit studies should cover main receiving station , switchgear , centralised reactive power compensation , kva-kms etc and also the possible improvements in the metering etc wherever feasible at main receiving station . , ( a ) review the power distribution system and electrical installations for protection systems adequacy and related hazards . ( b ) review of operation and maintenance system . ( c ) review of access and control for electrical installations for both ht and lt system . ( d ) to review adequacy of inspection and testing of protective equipment and protective tools . ( e ) study of transformers installation:- ( i ) inspection by walk through at the transformer inddor / outdoor locations and carrying out measurement with instruments at feeders and arriving at the loading patten , adequacy of swtichgear to quench fault , overloading etc and finding out percent loading . ( ii ) the audit scope will include study of nos of transformers from 63kva to 500 kva location under ge ( kh ) yol cantt jurisdiction their loading patten . ( iii ) reconfiguration , renetworking , load balancing , losses and efficiency and possible suggestion to improve efficiency and with recommendation of life based on life cycle cost . ( iv ) the audit scope will also include study reactive power compensation , power factor improvement and other system adjacents in the transformer substation . ( v ) power quality with power quality analyzer on 56 nos . of transformers current , voltage , power factor , harmonics up to 30hz , active power , energy loss calculator , ( a ) to review the adequacy of electrical ppe being used for electrical works including testing equipment . ( b ) review of emergency lighting adequacy . ( c ) vibration analysis: spectrum , time waveform , envelope spectrum of dg . ( d ) study of dg sets installation 20 kva to 200 kva :- ( i ) inspection by walk through at the dg set installations at various locations and carrying out measurement with instruments . ( ii ) motors / mccbs / acbs / sfus / fus / changeovers etc and arriving at the loading pattern , adequacy of switchgear to quench fault , overloading etc and finding out percent loading . parallel running and diverting critical load will be seen at the dg sets locations . ( iii ) the study would include specific fuel consumption and per unit cost of generating electricity besides working out alternate fuel strategy and energy efficiency point of view for reactive power compensation . , review of lightning protection system ( basis of review: design calculations and recommendations report , made available to the auditor ) to review overall understanding of the electrical safety requirements by operations and maintenance staff . , study of street light system :- ( i ) inspection by walk through at the various street lighting in cantt area covering street light panels fucntioning of photo switches , controls , relay , timer and other control and taking measurement at strategic points in cantt . ( ii ) comperehensive study of the entire lighting system covering the light source ( lamps ) , luminaire ( reflectors etc ) and the gear ( ballast / drivers ) would be taken up for the street light feeders of the premises . ( iii ) besides this the illumination levels on the roads required viz-a-viz available would also be studied . recommendations of auditor to implement in efficiency of lighting system note : the rate quoted is for entire lighting system from control panel to end light will be considered as one job . , thermography of panels to be done by flir e series thermal imager at each panel . , to review protective earthing system of all the substations / installation of cantt premisses . , complete sketch on acrylic sheet of size 2mtr x 3mtr of existing electric system ( ht & lt network with different colour ) shown with location of all substation and power transformer location ( hard and soft duplicate copy ) . , fire safety audit , judicious utilisation of electric supply at various location in cantt with standard electric pattern in otms , offices and residential accommodations and recommendation render report in details for each job , illumination measurement lux level monitoring at electrical room . , electrical safety audit for domestic ac , refrigerator , induction motors and ups under ge ( kh ) yol jurisdiction .
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 02656270-99fd-4f9c-a951-5cdcc44ec782
Download File Name File Description
Download BOQ_393467 Tender Documents - BOQ
Download Tendernotice_1 Tender Documents - NIT
Download TenderDocuments631920. Tender Documents - Tender documents
Download ADA1D277-5F0E-466C-A3E4-FC264325E48F Tender Documents - Tender Notice
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders