BRR : 1728869
Click Here To View Tendering Authority. Aoc City/State :  kunnamangalam, Kerala
Tender Brief : Tender For Annual Plan-Vellanur Laksham Veedu Colony Pakal Veedu Phase 2 -Electrification-General Electrical Work. 1 Electrification 2 90.2.1.1:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing... Read More
Tender Value
72,442
Contract Value
₹ 62,230
Saving / Difference
₹ 10,212 ▲
Submission Date
26-06-2023
Contract Date
17-11-2023
Completion Date
90 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 62,230 L1
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics 62,230 L1
Work Detail
tender for annual plan-vellanur laksham veedu colony pakal veedu phase 2 -electrification-general electrical work. 1 electrification 2 90.2.1.1:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point with 6a, plate ceiling rose - short point 3 90.2.1.3:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point without ceiling rose - short point 4 90.2.1.4:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control ceiling fan point with 6 a, 3 plate ceiling rose & with socket size stepped electronic regulator. - short point 5 90.2.1.6:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .combined plug point with 6 a, 5 pin plug socket controlled by 6 a, switch in the same switch board as that of light points 6 90.2.1.8:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point with 6a, plate ceiling rose - medium point 7 90.2.1.9:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .twin control light point with 6a, plate ceiling rose - medium point 8 90.2.1.10:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point without ceiling rose - medium point 9 90.2.1.11:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control ceiling fan point with 6 a, 3 plate ceiling rose & with socket size stepped electronic regulator - medium point. 10 90.2.1.14:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .independent plug - medium point 11 90.2.1.17:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point without ceiling rose - long point 12 90.2.1.21:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .independent plug - long point 13 90.3.19.3:supply conveyance, installation, testing and commissioning the light fittings of following types made from crca sheet 0.5mm thickness with all accessories andlamps directly on wall and giving connections with 16 / 0.20 mm 3 core pvc insulated and sheathed round copperconductor flex wire or extending the original wiring and giving connections as required1200 mm 1x20w led lamp with box type fixture 14 90.3.21.3:supply & installation of light fittings on c / u shaped flat iron bracket
supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm crca sheet complete with all accessories andlamps etc. directly on wall using 2 nos. c / u brackets made from 20 x 3 mm ms flat, painting the flat iron bracket and giving connections with required length of 16 / 0.20mm 3 core copper conductor flex wire conforming to relevant iss or extending the original wiring and giving connection etc. as required.1200 mm 1x20w led lamp with box type fixture 15 90.4.1:supply and installation of suitable size ms rod type fan clamp in the rcc slab as per is 732 as required. 16 90.4.5.4:supply, installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length ( up to 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0 ( cub meter / minute / watt ) , air delivery minimum 210 ( cubic meter / minute ) , copper winding suitable for 230v / 240v single phase ac supply 17 90.4.8:charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 18 90.6.10.1:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 19 90.16.1.3:supply and drawing bare earthing conductors of the following sizes along with wiring / cables and giving connection as required3.15 mm copper conductor ( 10 swg ) 20 90.16.5.3:supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm ( 10 swg ) 21 1.58:supplying and fixing pvc batten / angle holder including connection etc. as required. 22 2.3.2:supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcbirccb / isolator8 way, double door 23 2.10.1:supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 24 2.10.3:supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.double pole 25 2.11:supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 26 2.14.1:supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 volts, residualcurrent circuit breaker ( rccb ) , having a sensitivity current upto 300 milliamperes in the existing mcb db complete with connections, testing and commissioning etc. as required.25 amps 27 od37755 / 2022-2023:supply and fixing of 400mm sweep wall mounting fan of bajaj make or equivalent 28 od40645 / 2022-2023:supplying and fixing 12w led bub gm or equivalent make, lumens greater than 1200lm 29 1.14.1:wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 30 od305591 / 2022-2023:earthing with gi earth pipe 2.5m long 40mm dia including accessories , and providing masonry enclosure with cover plate having locking arrangements and watering pipe etc. ( but without charcoal and salt ) as required. 31 od305829 / 2022-2023:supply and fixing of 300 / 305 mm sweep light duty exhaust fan in metal frame working on 230 v a / c
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 40506aea-fef3-4c41-9490-49ff1f4c7c5f
Download boqcomparativechart
Download finance_860704
Download finsummary_860704
Download File Name File Description
Download 409a7200-04e8-4634-9663-3d0ae4453acc Tender Documents
Download AFFI.pdf Tender Documents
Download BOQ_860704 Tender Documents
Download fot.pdf Tender Documents
Download PRELI.pdf Tender Documents
Download Tendernotice_1 Tender Documents
Download Tendernotice_2 Tender Documents
Download Tendernotice_3 Tender Documents
Download viewsbd Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders