BRR : 1567130
Click Here To View Tendering Authority. Aoc City/State :  guruvayur, Kerala
Tender Brief : Providing Computer Nodes In Research Scholars Room For Malayalam And Commerce Department At Sree Krishna College Guruvayur Under Guruvayur Devaswom- 1 Computer Wiring 2 90.6.10.1 : Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required 20Mm 3 90.6.10.2 : Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Req... Read More
Tender Value
Ref. Document
Contract Value
₹ 2,17,478
Submission Date
07-08-2023
Contract Date
23-09-2023
Completion Date
30 days
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 2,18,444 L2
2 cnet-technologies Bid Analytics 2,17,478 L1
Work Detail
providing computer nodes in research scholars room for malayalam and commerce department at sree krishna college guruvayur under guruvayur devaswom- 1 computer wiring 2 90.6.10.1 : supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required 20mm 3 90.6.10.2 : supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required 25mm 4 1.17.2 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.2 x 1.5 sq. mm 5 1.17.4 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.4 x 1.5 sq. mm 6 1.17.6 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.6 x 1.5 sq. mm 7 1.17.11 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.2 x 2.5 sq. mm 8 1.17.13 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.4 x 2.5 sq. mm 9 1.17.20 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.2 x 4 sq. mm 10 1.24.1 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5 / 6 amps switch 11 1.24.3 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15 / 16 amp switch 12 1.24.4 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5 / 6 amp socket outlet 13 1.24.5 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15 / 16 amp socket outlet 14 1.26 : supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 15 1.27.2 : supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.3 module ( 100mmx75mm ) 16 1.27.5 : supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.8 module ( 125mmx125mm ) 17 90.10.1.3 : supply & fixing the following types / sizes of boxes suitable for modular accessories in surface / recess including making good the damages, colour washing etc as required ( rohs compliant ) 3 moduled plastic box on surface 18 90.10.1.6 : supply & fixing the following types / sizes of boxes suitable for modular accessories in surface / recess including making good the damages, colour washing etc as required ( rohs compliant ) moulded plastic box on surface 19 1.28.2 : supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required.3 module 20 1.28.5 : supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required.8 module 21 90.9.2.1 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.100x50mm cms with base and lid 22 90.9.2.2 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.cable devider 23 90.9.2.3 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.external angle 90 degree 24 90.9.2.5 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.internal angle 90 degree 25 90.9.2.8 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.end cap 26 2.3.3 : supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcbirccb / isolator12 way, double door 27 2.3.4 : supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcbirccb / isolator16 way, double door 28 2.10.1 : supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 29 2.12.1 : supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.40 amps 30 2.14.1 : supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required.25 amps 31 2.16 : supplying and fixing dp sheet steel enclosure on surface / recess along with 25 / 32amps 240 volts c curve dp mcb complete with connections, testing and commissioning etc. as required. 32 90.16.1.1 : supply and drawing bare earthing conductors of the following sizes along with wiring / cables and giving connection as required 2.00 mm copper conductor ( 14 swg ) 33 90.16.1.2 : supply and drawing bare earthing conductors of the following sizes along with wiring / cables and giving connection as required ( 12 swg ) 34 90.16.5.1 : supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. ( 14 swg ) 35 90.16.5.2 : supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. ( 12 swg ) 36 od400585 / 2022_2023 : supply and providing the following sizes of bolt and nut with washers on the existing ms box / earth bus etc. as required including drilling necessary holes as required.12 x 3 mm brass bolt & nut
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download b46220ba-466a-48c4-ba33-abf1392451a3
Download boqcomparativechart
Download finance_875610
Download finsummary_875610
Download SKCcomputernode
Download techsummary_875610
Download File Name File Description
Download 08413804-4341-4772-9ebc-f677092b70bc Tender Documents
Download Agreement200Page2 Tender Documents
Download agreementpage1 Tender Documents
Download BOQ_875610 Tender Documents
Download materialslist Tender Documents
Download NIT Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders