BRR : 12293389
Click Here To View Tendering Authority. Technical Bid City/State :  Jhalawar, Rajasthan
Tender Brief : Tender for Procurement Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar (2X600 Mw) , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range: 0 To 15 User Range/Calibration Range: 0 To 15 , Pt No1 Hph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 10 User Range/Calibration Range: 0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs, Hpturb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs, Reater Interlocking Stm Prs, Crh To Bept Stm Prs, Rh O/Lstm Press, Rh O/L Stm Press, Rh O/L Stm Press, No2 Hphi/L Stm Prs, Crh To Bfp... Read More
Tender Value
₹ 54,28,222
Submission Date
06-08-2026
Participated Bidder List
6 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics
5 cnet-technologies Bid Analytics
6 cnet-technologies Bid Analytics
Work Detail
tender for procurement of pressure transmitter (pt) and differential pressure transmitter (dpt) at katpp, jhalawar (2x600 mw) , pt turbine stm prs after gov stage1 unit: mpa measuring range: 0 to 15 user range/calibration range: 0 to 15 , pt no1 hph interlocking stm prs unit: mpa measuring range: 0 to 10 user range/calibration range: 0 to 10 , pt hpbp behind stm prs 1, hp turb exhaust stm left prs, hpturb exhaust stm right prs, hp turb exhaust stm hdr pipe prs, reater interlocking stm prs, crh to bept stm prs, rh o/lstm press, rh o/l stm press, rh o/l stm press, no2 hphi/l stm prs, crh to bfpt stm prs, cold rh stm to aux stm prs, no 2 hph interlocking stm unit: mpa measuring range: 0 to 6 user range/calibration range: 0 to 6 , pt dearator press 1,4 sect. extr. to aux stm prs, 4 sect. extr. to dea mov frt prs, 4# extr. to mfpt press, aux stm to bfpt, stm prs., mfpt a interlocking stm prs., aux stm to bfpt stm prs, gen stat cw interlocking wtr flow, no5 lph interlocking stm prs, turb hp&ip gas gland stm prs. 1, gen entering hydrogen pr. no5 lph interlocking stm prs unit: mpa measuring range: 0 to 2 user range/calibration range: 0 to 2 , pt lpbp vlv(hp) behind stm prs 1, lpbp vlv (lp) behind stm prs 1 unit: mpa measuring range: -0.2 to 2 user range/calibration range: -0.1 to 2 , pt no7 lph a&b interlocking stm prs, no8 lph a&b interlocking stm prs 1 unit: mpa measuring range: -0.1 to 0.1 user range/calibration range: -0.1 to 0.1 , pt cp inl press unit: mpa measuring range: -0.1 to 0.5 user range/calibration range: -0.1 to 0.5 , pt lub oil of turb prs unit: kpa measuring range: 0 to 5500 user range/calibration range: 0 to 5500 , pt hp cond vacuum pres 1, lp cond vacuum press 1, hp cond vacuum prs 1, lp cond vacuum prs 1, bfpt b exhaust vac press, bfpt a exhaust vac press unit: kpa measuring range: -100 to 100 user range/calibration range: -100 to 100 , dpt tdbfbp a interlocking filter dp, tdbfbp b interlocking filter dp, tdbfbd o/l feed wtr flow 2, tdfpa interlocking filter dp, tdfp a interlocking filter dp, mbfbp interlocking filter dp, mbfp interlocking filter dp, rh spray wtr flow, sh spray wtr flow 1, 4# extr. to aux stm flow, 4# extr. to mfpt unit: kpa measuring range: 0 to 100 user range/calibration range: 0 to 100 , pt trub self-sealing gland htr prs unit: kpa measuring range: -100 to 600 user range/calibration range: -100 to 600 , dpt gen stat cw flow, seal oil dp, hp bpv in steam flow unit: kpa measuring range: 0 to 250 user range/calibration range: 0 to 250 , dpt tdbfbp a o/l feed wtr flow 1, tdbfbp b o/l feed wtr flow 1, tdbfbp b o/l feed wtr flow 3, mbfbp o/l feed wtr flow 1 unit: kpa measuring range: 0 to 40 user range/calibration range: 0 to 40 , dpt drum level tx. unit: mmh2o measuring range: -800 to 800 user range/calibration range: -600 to 500 mmh2o , dpt pa flow, aph pa inlet & outlet dp, secondary air flow, aph sa inlet & outlet dp unit: kpa measuring range: -2.0 to 2.0 user range/calibration range: 0.1 to 1.5 , dpt feed control stn in & out dp unit: mpa measuring range: -0.12 to 10.0 user range/calibration range: 0 to 10.0 , pt furnace press tx., aph inlet and outlet gas press, esp intel gas press, id fan inlet press, gas press fur. cavity unit: kpa measuring range: -8.0 to 8.0 user range/calibration range: -8.0 to 1.0 , pt main feedwater press, drum press tx., sh out press, main steam press, sh spray water press., main feedwater mov front press., construction blowdown tank press. unit: mpa measuring range: -0.1 to 40.0 user range/calibration range: 0 to 30.0 , pt secondary air pressure tx., aph inlet sec air press, fd fan out press, furnace sec. air box press, furnace pressure unit: kpa measuring range: -60 to 60 user range/calibration range: -7.0 to 7.0 , pt cw/acw header pressure, instrument air pressure, cw outlet pressure iac/cac air pressure unit: mpa measuring range: 0 to 1.5 user range/calibration range: 0 to 1.5 , pt ldo , hfo supply and return press (with capillary) unit: mpa measuring range: 0 to 05 user range/calibration range: 0.1 to 05 , pt prds hdr press unit: mpa measuring range: 0 to 6.3 user range/calibration range: 0 to 5 , pt mill loading oil pressure unit: mpa measuring range: 0 to 40 user range/calibration range: 0 to 25 , dpt mill sealing air dp, sadc/cadc press dp unit: kpa measuring range: -60 to 60 user range/calibration range: 0 to 5 , dpt hfo filter dp (with capillary) unit: kpa measuring range: -500 to 500 user range/calibration range: -100 to 100 , dpt lo filter dp (with capillary) unit: kpa measuring range: -160 to 160 user range/calibration range: 0 to 100 , dpt mill separator inlet/outlet dp unit: kpa measuring range: 0 to 40 user range/calibration range: 0 to 20 , dpt scanner fan dp unit: kpa measuring range: 0 to 8 user range/calibration range: 0 to 6.2 , pt scanner fan press., mill separator outlet pressure, mill seal air pressure, mill pa pressure unit: kpa measuring range: -100 to 400 user range/calibration range: 0 to 30 , pt mill lube oil pressure line unit :mpa measuring range :-0 to 0.5 user/calibration range :-0 to 0.2
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download ca7e9655-558b-4922-b1c2-ce49735ffc40 technicalevaluation notice
Download techsummary_1018083 document
Download File Name File Description
Download 8da9a88e-7a27-4ba5-856c-22ba4ec1ed39 Tender Documents
Download BOQ_1018083 Tender Documents
Download Tendernotice_1 Tender Documents
Download TN1310 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.