BRR : 11965315
Click Here To View Tendering Authority. Aoc City/State :  Ratnagiri, Maharashtra
Tender Brief : Bids Are invited for Facility Management Services - Lumpsum Based - Industrial; Biennium Service Contract For Maintenance Of Mm Equipments, Preservation Etc For Hrsg And Bop Area At Rgppl; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Pm Of Chemical Dosing Pumps (Positive Displacement) ≤10 Kw , Pm Of Pumps Of Rating ≤ 15 Kw , Pm Of Pumps Of Rating> 15 Kw & ≤ 30 Kw Rating , Pm Of Pumps Of Rating> 30 Kw & ? 75 Kw Rating , Pm Of Pumps Of Rating> 75 Kw & ≤ 200 Kw Rating , Pm Of Pumps Of Rating> 200 Kw , Pump/ Valve Gland Packing Replacement/ Adjustment , Decoupling... Read More
Tender Value
Ref. Document
Contract Value
₹ 5,08,84,550
Submission Date
09-06-2026
Contract Date
Ref. Document
Completion Date
Ref. Document
Participated Bidder List
6 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics 5,37,03,663.22 L2
5 cnet-technologies Bid Analytics 5,08,84,550 L1
6 cnet-technologies Bid Analytics 7,28,04,940.31 L3
Work Detail
bids are invited for facility management services - lumpsum based - industrial; biennium service contract for maintenance of mm equipments, preservation etc for hrsg and bop area at rgppl; consumables to be provided by service provider (inclusive in contract cost) - pm of chemical dosing pumps (positive displacement) ≤10 kw , pm of pumps of rating ≤ 15 kw , pm of pumps of rating> 15 kw & ≤ 30 kw rating , pm of pumps of rating> 30 kw & ? 75 kw rating , pm of pumps of rating> 75 kw & ≤ 200 kw rating , pm of pumps of rating> 200 kw , pump/ valve gland packing replacement/ adjustment , decoupling & coupling/ spider replacement of pump/fan/blower/compressor , alignment of pump/fan/blower/compressor , mechanical seal adjustment/replacement of pump , pm of cooling tower fans (10 mtr fan dia) , pm of air compressor zt 90/110/ga 15/18 , pm of travelling water screens (intake) , pm of fans/ air blower ? 15 kw rating , pm of fans/ air blower > 15 kw rating , pm of mixers/ agitators , pm of compressor air dryer , pm of valve of ? 80 nb size , pm of valve of > 80 nb & ? 150 nb size , pm of valve of > 150 nb size & ? 250 nb size , pm of valve of > 250 nb size & ? 500 nb size , pm of valve of > 500 nb size , pm of gearboxes of valves , trash screen cleaning of ct bd/ ct cw/ inatke pumps , minor bd works of chemical dosing pumps ≤10 kw (without dismantling/ partial dismantling) , minor bd works of pump rating ≤ 15 kw(without dismantling/ partial dismantling) , minor bd works of pump rating > 10 kw & ? 30 kw (without dismantling/ partial dismantling) , minor bd works of pump rating > 30 kw & ? 75 kw (without dismantling/ partial dismantling) , minor bd works of pump rating > 75 kw & ? 200 kw(without dismantling/ partial dismantling) , minor bd works of pump rating > 200 kw(without dismantling/ partial dismantling) , minor bd works of cooling tower fans (10 mtr fan dia) and/or gearbox (without dismantling , minor bd works of air compressor zt 90/110/ ga 15/18 (without dismantling/ partial dismantling) , minor breakdown works of fans/ air blower ? 15 kw rating (without dismantling/ partial dismantling) , minor bd works of fans/ air blower > 15 kw rating (without dismantling/ partial dismantling) , minor bd works of gear box (without dismantling/ partial dismantling) , minor bd works of pulley belts chain (without dismantling/ partial dismantling) , routine maintenance of instrument air dryer (without dismantling/ partial dismantling) , balancing work of pumps, fans, blowers (without dismantling/ partial dismantling) , minor bd works of mixers/ agitators (without dismantling/ partial dismantling) , oil top up/ greasing per equipment , routine maintenance of valves (with/ without actuator) class upto 3000 size ? 80 nb , routine maintenance of valves (with/ without actuator) class upto 3000 size > 80 nb & ? 150 nb , routine maintenance of valves (with/ without actuator) class upto 3000 size > 150 nb & ? 250 nb , routine maintenance of valves (with/ without actuator) class upto 3000 size > 250 nb & ? 500 nb , routine maintenance of valves (with/ without actuator) class upto 3000 size > 500 nb , setting of deluge valves spray nozzle replacement (fire protection) , safety shower/eye washer maintenance , valve actuator/ gear box servicing , ct hot basin cleaning distribution valve servicing (each cell) , y strainer/cyclone separator/single cartridge element or filter cleaning /replacement , suction strainer cleaning for pipe size up to 12 , suction strainer cleaning for pipe size more than 20 , cartridge filter replacement (in set of 10 nos in each opn.) , repair & maintenance of piping/structural works as per work specification , replacement/new fabrication of piping upto 80nb as per work specification(=1 mtr length each work) , replacement/new fabrication of piping > 80nb as per work specification(=1 mtr length each work) , replacement/new fabrication of structural parts as per work specification (upto100 kg for each work) , erection/dismantling of scaffolding work as per work specification , application of sealants/leak arresting compounds/wraps , replacement of gaskets for flange size ?100 nb , replacement of gaskets for flange size >100 nb?300 nb , replacement of gaskets for flange size >300 nb , tightening of bolts for flanged joints , fixing/dismantling of unloading hoses for tankers , new fabrication /erection of structures metal work piping including cutting/welding work , laying/dismantling of temporary pipes(with available materials) , coupling and decoupling of valves , installation/ maintenance of level gauge , new installation/ replacement of threaded pipe fittings(elbow nipple unions etc.) upto 3 inch. , new installation/ replacement of pvc/ cpvc pipe and fittings≤ 3 inch. , new installation/ replacement of pvc/ cpvc pipe and fittings of size >3 inch and ≤ 6 inch. , new installation/ replacement of pvc/ cpvc pipe and fittings of size >6 inch and ≤ 12 inch. , repairing of hdpe pipe line size upto 100nb as per work specification , repairing of hdpe pipe line size >100 nb?450 nb as per work specification , repairing of hdpe pipe line size above 450 nb and upto 860 mm as per work specification , pump major oh/ replacement of ≤ 15 kw rating , pump major oh/ replacement of >15 kw and ≤ 30 kw rating , pump major oh/ replacement of > 30 kw and ≤ 75 kw rating , pump major oh/ replacement of > 75 kw & ? 200 kw rating , pump major oh/ replacement of > 200 kw rating , major replacement of inlet/ outlet expansion bellow size up to 300mm , major replacement of inlet/ outlet expansion bellow size up > 300mm , major oh/ replacement of cooling tower fans & gearbox replacement/ maintenance , major oh/ replacement of fans/ air blower ? 15 kw rating , major oh/ replacement of fans/ air blower > 15 kw rating , major oh/ replacement of air compressor zt 90/110/ ga 15/18 , major oh/ replacement of travelling water screens , major oh/ replacement of air dryer maintenance including alumina replacement , major oh/ replacement of ? 80 nb size , major oh/ replacement of > 80 nb & ? 150 nb size , major oh/ replacement of > 150 nb size & ? 250 nb size , major oh/ replacement of > 250 nb size & ? 500 nb size , major oh/ replacement of > 500 nb size , inspection repair replacement of hrsg pipe penetration bellows expansion joints , manhole/inspection access opening inspection assistance closer of manholes above 500mm dia opening , dewatering cleaning removal of sludges , internal cleaning of tanks- capacity 48000 m³( fost & fnst- water storage tanks , internal cleaning of tanks-capacity 8000 m³( rwst,neutralization tank,fwst,dm water tank,swro plant , material handling (shifting from one location to other location ?1000 kg each time) , installation of dewatering pumps/ sump pumps as per instruction of eic , support services for colony/ incinerator maintenance , assistance/ support services during inspection & maintenance of equipments like bfp cw pumps , assistance / support services for hrsg during unit startup/ shutdown , assistance/ support services as per work specification , desilting of intake well and pump suction basin , hrsg internal floor cleaning & inspection , hrsg drum internal cleaning & inspection , hand rotation of rotor & freeness checking of pumps/fan/blower of all size , preventive maintenance/ filters cleaning of preservation dehumidifiers in hrsg , maintenance of preservation dehumidifiers in hrsg , inspection repair replacement any parts of hrsg internals hydro testing of hrsgs liasoning with , oil wear debris analysis , tube leak repair valve replacement of high pressure (hrsg)with ibr quality weld for <80nb size pipe , radiography/ paut testing of high pressure weld joints , replacement of high pressure(hrsg) bfp recirculation valve of size 3 to 4: nb with ibr quality weld , replacement of high pressure(hrsg) bfp discharge nrv/drum level control valves with ibr quality weld , phe complete cleaning by removing plates , ct splash bar & drift eliminator repair/replacement , freeness checking/greasing of all hrsg valves supports during shut down
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 801109fb-8f8d-4552-92f5-9074b8be66f5 result notice
Download File Name File Description
Download fba11d4b-7537-410d-920d-3e8005b93859 Tender Documents
Download 1778561032 Tender Documents
Download 1779103153 Tender Documents
Download 1779103157 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000