BRR : 11812909
Tender Brief : Tender for Supply Of Hemdirect Kit, Psa Semiquantkit And Amylase Test Kits , Particular , Hemdirect Kits 20X20 Box Total 400 Reaction (Rapid Body Fluid Identification Kit For Human Blood (Forensic Validated Kit) 1. Kit Should Be Forensically Validated 2. Kit Should Be Based On Human Hemoglobin (Hb) 3. Kit Should Be Specific For Human Blood Detection 4. The Cassettes Should Have A Feature Of Possible Semi- Quantitative Analysis Of Body Fluid. 5. The Detection Should Be Immuno Chromate- Graphy Based With High Specificity And High Sensitivity (99.5%) Towards Detected Body Fluid.) , Psa Semiquant... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 2,23,444
Submission Date
07-08-2026
Contract Date
10-08-2026
Completion Date
15 days
Participated Bidder List
1 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 2,23,444 | L1 |
Work Detail
tender for supply of hemdirect kit, psa semiquantkit and amylase test kits , particular , hemdirect kits 20x20 box total 400 reaction (rapid body fluid identification kit for human blood (forensic validated kit) 1. kit should be forensically validated 2. kit should be based on human hemoglobin (hb) 3. kit should be specific for human blood detection 4. the cassettes should have a feature of possible semi- quantitative analysis of body fluid. 5. the detection should be immuno chromate- graphy based with high specificity and high sensitivity (99.5%) towards detected body fluid.) , psa semiquant kits 20x10 box total 200 reaction (rapid body fluid identification kit for human semen (forensic validated kit) 1. kit should be forensically validated 2. kit should be based on prostate-specific antigen (psa) 3. kit should be specific for human semen detection 4. the cassettes should have a feature of possible semi- quantitative analysis of body fluid. 5. the detection should be lmmunochromatography based with high specificity and high sensitivity ( 99.5%) towards detected body fluid.) , amylase test kits 20x01 box total 20 reaction (rapid body fluid identification kit for human saliva (forensic validated kit) 1. kit should be forensically validated 2. kit should be based on human alpha amylase 3. kit should be specific for human saliva detection 4. the cassettes should have a feature of possible semi- quantitative analysis of body fluid. 5. the detection should be immunochromato graphy based with high specificity and high sensitivity (99.5%) towards detected body fluid. )
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 33182c20-04f2-4f50-b6d0-27549da98b6c | technicalevaluation notice |
| Download | techsummary_631647 | document |
| Download | b1f8f3dc-f4af-456c-ae3b-3dc909268d38 | result notice |
| Download | boqcomparativechart | document |
| Download | boqcomparativechart | document |
| Download | workorder | document |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results