BRR : 11252009
Click Here To View Tendering Authority. Technical Bid City/State :  chennai, Tamil Nadu
Tender Brief : Tender For Supply, Erection And Commissioning Of Chilled Water Outlet Header Pipe Lines And Bends With Insulation After Dismantling Of Damaged Chilled Water Pipe Lines And Bends , Supply, Erection And Commissioning Of Chilled Water Outlet Header Pipe Lines And Bends With Insulation After Dismantling Of Damaged Chilled Water Pipe Lines And Bends , Ms Erw Pipe 200 Nb (As Per Class C Heavy Duty Is 1239) (Including Insulation As Per Sl.No.04 Of Annexure - 1) Ms Erw 200 Nb Pipe Wall Thickness - 5.4 Mm Material - Mild Steel (As Per Class C Heavy Duty Is 1239) , Ms Erw Pipe 200 Nb - 90 Degree Bend (... Read More
Tender Value
Ref. Document
Submission Date
15-12-2025
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
Work Detail
tender for supply, erection and commissioning of chilled water outlet header pipe lines and bends with insulation after dismantling of damaged chilled water pipe lines and bends , supply, erection and commissioning of chilled water outlet header pipe lines and bends with insulation after dismantling of damaged chilled water pipe lines and bends , ms erw pipe 200 nb (as per class c heavy duty is 1239) (including insulation as per sl.no.04 of annexure - 1) ms erw 200 nb pipe wall thickness - 5.4 mm material - mild steel (as per class c heavy duty is 1239) , ms erw pipe 200 nb - 90 degree bend (as per class c heavy duty is 1239) ms erw 200 nb bend 90 degree bend material - mild steel (as per class c heavy duty is 1239) , ms 200/150 nb reducer material - mild steel (as per class c heavy duty is 1239) , charges for erection of new chilled water pipe line with fittings, insulation and dismantling the damaged insulated chilled water pipe line and devolution to stores details of wroks to be carried out: 1. dismantling the existing damaged insulation, plastering, wire mesh and damaged pipe of ucb-1, 2 & 3 control room area. 2. erection of the new ms erw pipeline with required m.s. bends and reducer. 3. providing the insulation with following steps. a) applying the liquid bituminous over the new pipe line. b) fixing the thermocole pipe section two halves in the new pipe line. (white colour, 50 mm thick, two halves pipe section) c) binding the chicken mesh over the thermocole pipe section (gi wire mesh ¾ x 24 swg) d) applying the second coat bituminous over the chicken mesh. e) plastering the pipe section of 25 mm thickness f) wrapping with tarfelt over the plastering pipe g) applying the bituminous final coat over the tarfelt. h) air releasing in the new pie line and commissioning satisfactorily
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download b77c0266-bc24-4e63-8336-55d09f347436 technicalevaluation notice
Download techsummary_750329 document
Download File Name File Description
Download 91c8a404-42af-4ae2-aff8-b217fc699a13 Tender Documents
Download BOQ_750329 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders