BRR : 1107889
Click Here To View Tendering Authority. Aoc City/State :  Edappally, Kerala
Tender Brief : Electrification Of Cytology Lab , Gmc , Kalamassery - Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And... Read More
Tender Value
4,59,075
Contract Value
₹ 4,23,038
Saving / Difference
₹ 36,037 ▲
Submission Date
28-06-2021
Contract Date
16-07-2021
Completion Date
30 days
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 4,23,037.86 L1
2 cnet-technologies Bid Analytics 4,42,548.56 L2
Work Detail
electrification of cytology lab , gmc , kalamassery - supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point with 6a, plate ceiling rose - short point 4 3 90.2.1.3 : supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control light point without ceiling rose - short point 4 90.2.1.4 : supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .single control ceiling fan point with 6 a, 3 plate ceiling rose & with socket size stepped electronic regulator. - short point 5 90.2.1.5 : supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .call bell point with 6 a bell push at one end and 6 a, 3 plate ceiling rose at other end - short point 6 90.2.1.6 : supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper, required quantity of copper earth socket, brass bolt and nut crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates ( white ) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. ( rohs compliant modular accessories ) .combined plug point with 6 a, 5 pin plug socket controlled by 6 a, switch in the same switch board as that of light points 7 90.3.19.3 : supply conveyance, installation, testing and commissioning the light fittings of following types made from crca sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16 / 0.20 mm 3 core pvc insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1x20w led lamp with box type fixture 8 90.3.21.3 : supply & installation of light fittings on c / u shaped flat iron bracket supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm crca sheet complete with all accessories and lamps etc. directly on wall using 2 nos. c / u brackets made from 20 x 3 mm ms flat, painting the flat iron bracket and giving connections with required length of 16 / 0.20mm 3 core copper conductor flex wire conforming to relevant iss or extending the original wiring and giving connection etc. as required.1200 mm 1x20w led lamp with box type fixture 9 od10954 / 2020_2021 : supply, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories and led panel square fitting etc. suspended from ceiling using 4 nos steel chain ( 16 swg or nearest available size ) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16 / 0.20mm 3 core copper conductor flex wire conforming to relevant iss or extending the original wiring and giving connection etc. as required.recess mounting type led panel square fitting 36 w 2x2 100 lm / w using 4 nos steel chain. ( luxpower fghe 36w 865 of osram / equivalent make ) 10 od10964 / 2020_2021 : supply, conveyance and fixing charges of recess mounting down light fittings of 9w complete with all accessories in the false ceiling, giving connections etc.as required. ( hawells make octane led panel square 9 w led 6500 k / equivalent reputed make having similar properties ) 11 od10966 / 2020_2021 : supply, conveyance and fixing charges of recess mounting down light fittings of 18w complete with all accessories in the false ceiling, giving connections etc.as required. ( hawells make octane led panel square 18 w led 6500 k / equivalent reputed make having similar properties ) 12 od10968 / 2020_2021 : supply, conveyance and fixing charges of recess mounting down light fittings of 24w complete with all accessories in the false ceiling, giving connections etc.as required. ( hawells make octane led panel square 24 w led 6500 k / equivalent reputed make having similar properties ) 13 90.4.8 : charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 14 od11613 / 2020_2021 : supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24 / 0.20mm pvc insulated and pvc sheathed 3 core round copper conductor flex wire conforming to relevant iss. 300 / 305 mm, single phase heavy duty exhaust fan in metal frame. 15 90.4.1 : supply and installation of suitable size ms rod type fan clamp in the rcc slab as per is 732 as required. 16 od10962 / 2020_2021 : supply and providing every additional length of down rod of suitable size heavy gauge gi / wi pipe with 16 / 0.20mm pvc insulated and pvc sheathed 3 core round copper conductor flex wire conforming in relevant iss or with original wiring extended including painting as required. 17 90.6.10.1 : supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 18 90.6.10.2 : supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required25 mm 19 90.9.2.1 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm cms with base and lid 20 90.9.2.8 : supply and fixing 100 x 50 mm pvc cable management system with base and lid along with the following accessories conforming to iec 61084 / bs 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.end cap 21 1.27.2 : supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.3 module ( 100mmx75mm ) 22 1.27.5 : supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.8 module ( 125mmx125mm ) 23 1.24.1 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5 / 6 amps switch 24 1.24.3 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15 / 16 amp switch 25 1.24.4 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5 / 6 amp socket outlet 26 1.24.5 : supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15 / 16 amp socket outlet 27 90.10.3.14 : supply and fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required ( rohs compliant ) 25a sp switch with indicator 28 90.10.3.33 : supply and fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required ( rohs compliant ) 25a 3pin shuttered socket 29 1.17.2 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.2 x 1.5 sq. mm 30 1.17.4 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.4 x 1.5 sq. mm 31 1.17.11 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.2 x 2.5 sq. mm 32 1.17.13 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.4 x 2.5 sq. mm 33 1.17.15 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.6 x 2.5 sq. mm 34 1.17.17 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.8 x 2.5 sq. mm 35 1.17.20 : supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required.2 x 4 sq. mm 36 90.12.7.40 : supply, laying and clamping of 1 no. pvc insulated and pvc sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 37 90.12.7.39 : supply, laying and clamping of 1 no. pvc insulated and pvc sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp 38 90.12.7.43 : supply, laying and clamping of 1 no. pvc insulated and pvc sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp 39 od9380 / 2020_2021 : supplying and providing earth clamps for siemens / tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.4 sqmm-16 sqmm with 12 mm wide x 1 mm thick clip 40 od9381 / 2020_2021 : supplying and providing earth clamps for siemens / tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.25 sq mm - 95 sq mm with 20 mm wide x 1.20 mm thick clip 41 od11615 / 2020_2021 : supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.4 x 6 sq. mm 42 9.1.32 : supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.4 x 10 sq. mm ( 25mm ) 43 9.1.35 : supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.4 x 35 sq. mm ( 32mm ) 44 90.16.1.1 : supply and drawing bare earthing conductors of the following sizes along with wiring / cables and giving connection as required2.00 mm copper conductor ( 14 swg ) 45 90.16.1.2 : supply and drawing bare earthing conductors of the following sizes along with wiring / cables and giving connection as required2.65 mm copper conductor ( 12 swg ) 46 90.16.5.1 : supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm ( 14 swg ) 47 90.16.5.2 : supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm ( 12 swg ) 48 od9382 / 2020_2021 : supply and providing 12x3mm brass nut and bolt etc. as required. 49 90.11.1.20 : supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of mcb db including copper / brass bus bar, neutral link, earth bus and din rail suitable for fixing mcb / isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way ( 8+12 ) - double cover tpn vertical db with provision for fixing mccb as incomer and sp / tp mcb as outgoing ( ip 42 / 43 ) 50 90.11.1.11 : supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of mcb db including copper / brass bus bar, neutral link, earth bus and din rail suitable for fixing mcb / isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way ( 8+18 ) - three phase double cover ( ip 42 / 43 ) 51 90.11.1.10 : supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of mcb db including copper / brass bus bar, neutral link, earth bus and din rail suitable for fixing mcb / isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way ( 8+12 ) - three phase double cover ( ip 42 / 43 ) 52 2.10.5 : supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.triple pole and neutral 53 2.10.4 : supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.triple pole 54 2.10.1 : supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 55 2.2.13 : providing and fixing following rating and breaking capacity and pole mccb in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 amp, 30 ka 4 pole 56 2.13.2 : supplying and fixing following rating, four pole, 415 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.63 amps 57 2.13.1 : supplying and fixing following rating, four pole, 415 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.40 amps 58 2.15.2 : supplying and fixing following rating, four pole, ( three phase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current upto 300 milliamperes in the existing mcb db complete with connections, testing and commissioning etc. as required.40 amps 59 od11785 / 2020_2021 : supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of mcb db including copper / brass bus bar, neutral link, earth bus and din rail suitable for fixing mcb / isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required.fp enclosure for independent mounting of mcb / rccb / rcbo. 60 90.4.5.4 : supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16 / 0.20mm pvc insulated and pvc sheathed 650 / 1100v grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0 ( cub meter / minute / watt ) , air delivery minimum 210 ( cubic meter / minute ) , 300mm down rod , 2 number canopies, shackele kit, copper winding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitable for 230v / 240v single phase ac supply etc. complete as required
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 1bd99527-a2a8-4e87-b3e4-b76db80406d8
Download File Name File Description
Download Tendernotice_1 Tender Documents - Preliminary agreement in stamp paper worth Rs.200
Download SBD Tender Documents - SBD
Download NIT Tender Documents - NIT
Download DDE21EDA-BDFF-4F18-A9E9-536E432D40DE Tender Documents - Tender Notice
Download BOQ_605926 Tender Documents - BOQ
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000