BRR : 10955689
Click Here To View Tendering Authority. Technical Bid City/State :  noida, Uttar Pradesh
Tender Brief : Tender For Framework Agreement (Rate Contract) Of Dc Battery Charger; 1 220V FLOAT-CUM-BOOST CHARGER1, 220V DC, 550A (MAIN PLANT) NOS 22 2 220V FLOAT-CUM-BOOST CHARGER2, 220V DC, 50A (OFFSITE) NOS 22 3 220V FLOAT-CUM-BOOST CHARGER1, 220V DC, 80A (CHP AHP) NOS 8 4 BATTERY FUSE BOX 4.1 BATTERY FUSE BOX FOR 550A CHARGER (BATTERY FUSE BOX OF ADEQUATE RATING AS PER LOAD DUTY CYCLE - ANNEXURE-I OF TECHNICAL SPECIFICATION, MINIMUM RATING 1250A) NOS 22 4.2 BATTERY FUSE BOX FOR 50A CHARGER (BATTERY FUSE BOX OF ADEQUATE RATING AS PER LOAD DUTY CYCLE - ANNEXURE-I OF TECHNICAL SPECIFICATION,... Read More
Tender Value
Ref. Document
Submission Date
28-11-2025
Participated Bidder List
7 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics
4 cnet-technologies Bid Analytics
5 cnet-technologies Bid Analytics
6 cnet-technologies Bid Analytics
7 cnet-technologies Bid Analytics
Work Detail
tender for framework agreement (rate contract) of dc battery charger; 1 220v float-cum-boost charger1, 220v dc, 550a (main plant) nos 22 2 220v float-cum-boost charger2, 220v dc, 50a (offsite) nos 22 3 220v float-cum-boost charger1, 220v dc, 80a (chp ahp) nos 8 4 battery fuse box 4.1 battery fuse box for 550a charger (battery fuse box of adequate rating as per load duty cycle - annexure-i of technical specification, minimum rating 1250a) nos 22 4.2 battery fuse box for 50a charger (battery fuse box of adequate rating as per load duty cycle - annexure-i of technical specification, minimum rating 50a) nos 22 4.3 battery fuse box for 80a charger (battery fuse box of adequate rating as per load duty cycle - annexure-i of technical specification, minimum rating 100a) nos 8 total of 4 i.e. (4.1+4.2+4.3) 5 discharge resistor 5.1 discharge resistor -1 {discharge resistor with shunt suitable for (1) 5 hrs discharge rate for 1680 ah ni-cd battery (two banks of 840 ah in parallel)/ 10 hrs discharge rate 3640ah lead acid battery (two banks of 1820ah in parallel).(2) heat run test & dynamic response test of charger} nos 7 5.2 discharge resistor -2{discharge resistor with shunt suitable for (1) 5hrs discharge rate for 90ah ni-cd battery (single string)/ 10 hrs discharge rate / 150ah lead acid battery (2) heat run test & dynamic response test of charger} nos 7 5.3 discharge resistor -3{discharge resistor with shunt suitable for(1) 5 hrs discharge rate for 150 ah ni-cd battery / 10 hrs discharge rate / 225 ah lead acid battery. (2) heat run test & dynamic response test of charger} nos 5 6 single cell boost charger 6.1 single cell boost charger (main plant) at boq sl. no. 1 nos 7 6.2 single cell boost charger (offsite) at boq sl. no. 2 nos 7 7 e & c spares 7.1 e & c spares for float cum boost charger (main plant) at boq sl. no. 1 set 7 7.1.1 fuse link without holder a ac i/p hrc fuse link nos 66 b glass fuse nos 66 c control hrc fuse link nos 66 d rectifier fuse link nos 66 e filter capacitor fuse link nos 66 f dc o/p fuse link nos 66 7.1.2 indicating lamp a ac i/p lamp red color nos 66 b ac i/p lamp yellow color nos 66 c ac i/p lamp blue color nos 66 d dc o/p lamp nos 66 7.1.3 set of electronic cards/ modules (1 set each type & rating) set 7 7.2 e & c spares for float cum boost charger (offsite ) at boq sl. no. 2 set 7 7.2.1 fuse link without holder a ac i/p hrc fuse link nos 48 b glass fuse nos 48 c control hrc fuse link nos 48 d rectifier fuse link nos 48 e filter capacitor fuse link nos 48 f dc o/p fuse link nos 48 7.2.2 indicating lamp a ac i/p lamp red color nos 48 b ac i/p lamp yellow color nos 48 c ac i/p lamp blue color nos 48 d dc o/p lamp nos 48 7.2.3 set of electronic cards/ modules (1 set each type & rating) set 7 7.3 e & c spares for float cum boost charger (chp ahp) at boq sl. no. 3 set 2 7.3.1 fuse link without holder a ac i/p hrc fuse link nos 12 b glass fuse nos 12 c control hrc fuse link nos 12 d rectifier fuse link nos 12 e filter capacitor fuse link nos 12 f dc o/p fuse link nos 12 7.3.2 indicating lamp a ac i/p lamp red color nos 12 b ac i/p lamp yellow color nos 12 c ac i/p lamp blue color nos 12 d dc o/p lamp nos 12 8 supervision of e&c(including tests on all battery chargers to be carried out at site on completion of e & c and immediately prior to putting in service) 8.1 lump sum charges per visit for engineer (except daily charges)-550a visit 55 8.2 lump sum daily charges for engineer-550a days 189 8.3 lump sum charges per visit for engineer (except daily charges)-50a visit 43 8.4 lump sum daily charges for engineer-50a days 147 8.5 lump sum charges per visit for engineer (except daily charges)-80a visit 8 8.6 lump sum daily charges for engineer-80a days 28 9 mandatory spares 9.1 mandatory spares for float cum boost charger (main plant-550a) at boq sl. no. 1 set 7 a set of electronic cards/ modules (1 set of each type and rating) set 7 b set of auxiliary relays (1 set of each type and rating) set 7 c set of fuse links & glass fuses (3 set of each type and rating) set 21 d 3 phase rectifier bridge complete assembly (1 set of each type and rating) set 6 e rectifier transformer (1 no. of each type and rating) nos 7 f control transformer (1 no. of each type and rating) nos 7 9.2 mandatory spares for float cum boost charger (offsite - 50a) at boq sl. no. 2 set 7 a set of electronic cards/ modules (1 set of each type and rating) set 7 b set of auxiliary relays (1 set of each type and rating) set 7 c set of fuse links & glass fuses (3 set of each type and rating) set 21 d 3 phase rectifier bridge complete assembly (1 set of each type and rating) set 6 e rectifier transformer (1 no. of each type and rating) nos 7 f control transformer (1 no. of each type and rating) nos 7 9.3 mandatory spares for float cum boost charger (chp-ahp - 80a) at boq sl. no. 3 set 2 a set of electronic cards/ modules (1 set of each type and rating) set 2 b set of auxiliary relays (1 set of each type and rating) set 2 c set of fuse links & glass fuses (3 set of each type and rating) set 6 d 3 phase rectifier bridge complete assembly (1 set of each type and rating) set 2 e rectifier transformer (1 no. of each type and rating) nos 2 f control transformer (1 no. of each type and rating) nos 2
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download d47947d6-b2c7-4060-9d3f-0cb98d8617b3 technicalevaluation notice
Download techsummary_58420 document
Download File Name File Description
Download 4c09a935-a940-46af-aa05-8948af1fecf0 Tender Documents
Download PRICEFORMAT Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders